Literature DB >> 34799440

Impact of using different predictive equations on the prevalence of chronic byssinosis in textile workers in Pakistan.

Asaad Ahmed Nafees1,2, Muhammad Zia Muneer3, Sara De Matteis2,4, Andre Amaral2, Peter Burney2, Paul Cullinan2.   

Abstract

OBJECTIVE: Byssinosis remains a significant problem among textile workers in low/middle-income countries. Here we share our experience of using different prediction equations for assessing 'chronic' byssinosis according to the standard WHO classification using measurements of forced expiratory volume in 1 s (FEV1).
METHODS: We enrolled 1910 workers in a randomised controlled trial of an intervention to improve the health of textile workers in Pakistan. We included in analyses the 1724 (90%) men who performed pre-bronchodilator spirometry tests of acceptable quality. We compared four different equations for deriving lung function percentage predicted values among those with symptoms-based byssinosis: the third US National Health and Nutrition Examination Survey (NHANES-III, with 'North Indian and Pakistani' conversion factor); the Global Lung Function Initiative (GLI, 'other or mixed ethnicities'); a recent equation derived from survey of a western Indian population; and one based on an older and smaller survey of Karachi residents.
RESULTS: 58 men (3.4%) had symptoms-based byssinosis according to WHO criteria. Of these, the proportions with a reduced FEV1 (<80% predicted) identified using NHANES and GLI; Indian and Pakistani reference equations were 40%, 41%, 14% and 12%, respectively. Much of this variation was eliminated when we substituted FEV1/forced vital capacity (FVC) ratio (<lower limit of normality) as a measure of airway obstruction.
CONCLUSION: Accurate measures of occupational disease frequency and distribution require approaches that are both standardised and meaningful. We should reconsider the WHO definition of 'chronic' byssinosis based on changes in FEV1, and instead use the FEV1/FVC. © Author(s) (or their employer(s)) 2022. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  air pollution; indoor; occupational health; respiratory system

Mesh:

Year:  2021        PMID: 34799440      PMCID: PMC7613213          DOI: 10.1136/oemed-2021-107680

Source DB:  PubMed          Journal:  Occup Environ Med        ISSN: 1351-0711            Impact factor:   4.948


Introduction

Byssinosis remains a significant problem among textile workers in low and middle-income countries where much global production is now located (1, 2). The disease is characterized by work-related symptoms of chest tightness and dyspnoea and, in its chronic form, by reductions in FEV1. There are two classification systems currently in place for byssinosis: that produced by the World Health Organisation (WHO) and the ‘Schilling criteria’ (3, 4). The most severe grade in the latter includes decrements in FEV1 in addition to presence of symptoms. The WHO approach, in contrast, recommends that respiratory symptoms and chronic changes in lung function are considered ‘together’, albeit as distinct health outcomes in epidemiological surveys, and that measurements of FEV1 should be compared with ‘data obtained from local populations or similar ethnic and social class groups’ (3). Such data, however, are seldom readily available. Here we share our experience of using different prediction equations for assessing ‘chronic’ byssinosis in Pakistani textile workers.

Methods

We recently completed the baseline survey of a cluster randomized trial of a multifaceted intervention to reduce the incidence of byssinosis among textile manufacturers in Karachi, Pakistan (5). We enrolled 1910 workers from 38 textile mills. Following ERS guidelines, trained technicians undertook pre- and post-bronchodilator spirometry using EasyOne spirometers (ndd Medizintechnik AG) and recorded up to eight measurements of FEV1, FVC and their ratio (6). We reviewed all spirograms; the analyses below include the 1724 (90%) men who performed pre-bronchodilator spirometry tests of acceptable quality. We compared four different equations for deriving lung function: those established through the third US National Health and Nutrition Examination Survey (NHANES-III; “Caucasian”) (7) with a conversion factor of 0.9 recommended for N. Indian and Pakistani individuals (8); the Global Lung Function Initiative (GLI, “other or mixed ethnicities”) equations (9); a recent equation derived from survey of a western Indian population (n=1258) aged 19-88 years (10); and one based on an older and smaller (n=504) survey of Karachi residents aged 16-65 years (11). We classified workers using the WHO recommended FEV1 cut-off for identification of workers at risk of developing permanent pulmonary impairment: FEV1 <80% predicted. We compared results based on this classification with one where we replaced FEV1 by FEV1/FVC ratio considering values below the normal limit of normality (LLN) to be abnormal. We undertook analyses in Microsoft Excel. The study was approved by the ethics committees at Aga Khan University, Karachi (2019-0962-3710), the National Bioethics Committee in Pakistan (4-87/NBC-402/19/483), and Imperial College London (19IC4968).

Results

Using symptom classification (alone) the prevalence of byssinosis was 3.4% (n=58) and 3.9% (n=67) according to WHO and Schilling’s criteria, respectively – reflecting the grade ½ (9 workers) in the latter. Of the 58 men with byssinosis according to WHO criteria, the proportion with a reduced FEV1 (<80% predicted) varied according to which set of predictive equations was used, from 40%-41% with those from NHANES and GLI, to 12%-14% with the more locally derived models (Table 1). Much of this variation was eliminated when we substituted FEV1/FVC ratio (
Table 1

proportion of workers with airway obstruction, by different criteria and reference equations, in those with symptoms of byssinosis and in the total mill population

Metric of airflow obstructionWorkers with symptoms of byssinosis (n=58)Total mill population (n=1724)
NHANES (7)GLI (9)Indian (10)Pakistani (11)NHANESGLIIndianPakistani
FEV1<80% predicted40%41%14%12%1.3%1.4%0.5%0.4%
FEV1/FVC ratio<LLN12%24%21%NA0.4%0.8%0.7%NA

NHANES: National Health and Nutrition Examination Survey III

GLI: Global Lung Initiative

NA: not available

Discussion

The substantial variation in the prevalence of abnormal FEV1, consistent with standard classifications of ‘chronic’ byssinosis, resulting from the use of different lung function prediction equations in this population reinforces the WHO recommendation that reference data from ‘local’ populations be used. Whether the stipulation for data from ‘similar social class groups’ is met is more difficult to ascertain since these are seldom reported for the populations from which predicted values are derived. It is evident that the widely used GLI (in which there is a lack of representation of South Asian populations) and NHANES III equations (even after adjustment) give a very different picture of the prevalence of lung function abnormality when this is expressed by FEV1, and therefore may not be useful in a local/regional South Asian context. Much textile manufacture now takes place in populations that are poorly served by spirometric norms, and the problem we have identified in Pakistan will be reflected in many other LMICs (1, 2). In contrast, substitution of FEV1 with FEV1/FVC ratio, with a LLN criterion of abnormality, produces estimates of airway obstruction that are relatively stable across different prediction equations, including the GLI. Since the FEV1 is correlated with the FVC, it is not an unambiguous measure of obstruction, and for this the FEV1/FVC, in which the FEV1 is adjusted for lung size, is preferable for defining obstruction. In the current context this has the added advantage that it is largely independent of ethnicity, the ethnic differences in FEV1 and FVC largely cancelling each other out. A potential limitation of our work includes the effect of a ‘healthy worker effect’ and the consequent underestimation of the risk of byssinosis in this context; it is improbable that this will have affected our findings in relation to the relative merits of FEV1 and FEV1/FVC ratio. Reproducible measurements of FVC are more difficult than those of FEV1 and require greater technical skill. Finally, the information provided by the authors of the reference equation for Pakistanis (11) was insufficient to calculate an LLN. Notwithstanding this, all efforts should be made to reduce exposures to cotton dust to identify byssinosis early through periodic workplace surveillance for the presence, nature, and extent of characteristic symptoms and before lung function loss has occurred. Exposures in the workplace may be important causes of respiratory disease (12) and especially so in LMICs where occupational health and safety measures may be poor. The basis for the prevention of the important public health burden of occupational disease is accurate measures of its frequency and distributions which requires approaches to its recognition and classification that are both standardised and meaningful. We should reconsider the WHO definition of ‘chronic’ byssinosis based on changes in FEV1 and substitute it with the use of FEV1/FVC.
  11 in total

1.  Standardisation of spirometry.

Authors:  M R Miller; J Hankinson; V Brusasco; F Burgos; R Casaburi; A Coates; R Crapo; P Enright; C P M van der Grinten; P Gustafsson; R Jensen; D C Johnson; N MacIntyre; R McKay; D Navajas; O F Pedersen; R Pellegrino; G Viegi; J Wanger
Journal:  Eur Respir J       Date:  2005-08       Impact factor: 16.671

2.  Spirometric reference values in healthy, non-smoking, urban Pakistani population.

Authors:  Muhammad Asif Memon; Muhammad Perwaiz Sandila; Syed Tausif Ahmed
Journal:  J Pak Med Assoc       Date:  2007-04       Impact factor: 0.781

3.  Spirometric reference values from a sample of the general U.S. population.

Authors:  J L Hankinson; J R Odencrantz; K B Fedan
Journal:  Am J Respir Crit Care Med       Date:  1999-01       Impact factor: 21.405

Review 4.  Lung volumes and forced ventilatory flows. Report Working Party Standardization of Lung Function Tests, European Community for Steel and Coal. Official Statement of the European Respiratory Society.

Authors:  P H Quanjer; G J Tammeling; J E Cotes; O F Pedersen; R Peslin; J C Yernault
Journal:  Eur Respir J Suppl       Date:  1993-03

Review 5.  Recommended health-based occupational exposure limits for selected vegetable dusts.

Authors: 
Journal:  World Health Organ Tech Rep Ser       Date:  1983

6.  Respiratory impairment in cotton-ginning workers exposed to cotton dust.

Authors:  Kamalesh J Dube; Lalit T Ingale; Sopan T Ingle
Journal:  Int J Occup Saf Ergon       Date:  2013

7.  Multi-ethnic reference values for spirometry for the 3-95-yr age range: the global lung function 2012 equations.

Authors:  Philip H Quanjer; Sanja Stanojevic; Tim J Cole; Xaver Baur; Graham L Hall; Bruce H Culver; Paul L Enright; John L Hankinson; Mary S M Ip; Jinping Zheng; Janet Stocks
Journal:  Eur Respir J       Date:  2012-06-27       Impact factor: 16.671

Review 8.  The Occupational Burden of Nonmalignant Respiratory Diseases. An Official American Thoracic Society and European Respiratory Society Statement.

Authors:  Paul D Blanc; Isabella Annesi-Maesano; John R Balmes; Kristin J Cummings; David Fishwick; David Miedinger; Nicola Murgia; Rajen N Naidoo; Carl J Reynolds; Torben Sigsgaard; Kjell Torén; Denis Vinnikov; Carrie A Redlich
Journal:  Am J Respir Crit Care Med       Date:  2019-06-01       Impact factor: 21.405

9.  MultiTex RCT - a multifaceted intervention package for protection against cotton dust exposure among textile workers - a cluster randomized controlled trial in Pakistan: study protocol.

Authors:  Asaad Ahmed Nafees; Sara De Matteis; Muhammad Masood Kadir; Peter Burney; David Coggon; Sean Semple; Paul Cullinan
Journal:  Trials       Date:  2019-12-16       Impact factor: 2.279

10.  Cotton Dust Exposure and Respiratory Disorders among Textile Workers at a Textile Company in the Southern Part of Benin.

Authors:  Antoine Vikkey Hinson; Virgil K Lokossou; Vivi Schlünssen; Gildas Agodokpessi; Torben Sigsgaard; Benjamin Fayomi
Journal:  Int J Environ Res Public Health       Date:  2016-09-08       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.