OCT applications in contact lens fitting.

Gonzalo Valdes1, Maria Romaguera2, Maria Serramito2, Alejandro Cerviño3, G Gonzalo Carracedo2.   

Abstract

Optical Coherence Tomography (OCT) is a noninvasive, high-speed, high-resolution imaging technology based in the Michaelson interferometry. A near-infrared light beam is used to register the intensity variations for the light backscattered on each sample layer. Due to the high repeatability on corneal measurements, spectral domain OCT (SD-OCT) is the gold standard when talking about in vivo, non-invasive anterior segment imaging. Changes in the morphology of various ocular surfaces such as the cornea, conjunctiva, limbus or tear film with soft (SCL), rigid, corneal or scleral lens (SL) wear can be described by OCT measurements. For instance, evaluation of the corneoscleral region is essential on SL fitting. For orthokeratology lenses central epithelial thinning and peripheral thickening and their regression could be quantified with OCT after Ortho-K lens wear. Blood vessel compression on the landing zone as well as vault thickness and fluid reservoir (FR) turbidity could be imaged with OCT. Tear film evaluation on contact lens wearers is essential because its use could lead to variations on the biochemical components in tears. Changes in tear meniscus dynamics and several parameters such as volume (TMV), tear meniscus height (HMT) and turbidity could be determined with OCT and positively correlated with the instillation of different ophthalmic solutions with Non-Invasive Break Up Time (NIBUT) and Schirmer test values. This manuscript shows the increasing applicability of OCT technology for the in vivo characterization of contact lens fitting and interaction with the ocular surface in a faster, safer and non-invasive way. Future research will still allow exploring OCT imaging to its full potential in contact lens practice, as there is still a significant amount of information contained in the images that are not yet easy to extract, analyze and give clinical value.
Copyright © 2021. Published by Elsevier Ltd.

Entities:  

Keywords:  Anterior segment imaging; Contact lens; Optical coherence tomography; Orthokeratology; Scleral contact lens; Tear meniscus

Mesh:

Year:  2021        PMID: 34799247     DOI: 10.1016/j.clae.2021.101540

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.946


  3 in total

1.  Results of the Pinhole Test Correlate with Hybrid Contact Lens Visual Acuity in Patients with Visual Impairment due to Corneal Diseases.

Authors:  Piotr Kanclerz
Journal:  J Ophthalmol       Date:  2022-06-24       Impact factor: 1.974

Review 2.  How Can We Best Measure the Performance of Scleral Lenses? Current Insights.

Authors:  Rute J Macedo-de-Araújo; Daddi Fadel; Melissa Barnett
Journal:  Clin Optom (Auckl)       Date:  2022-04-07

3.  Applications of Optical Coherence Tomography in the Ocular Diagnosis: From the Tear Film to the Sclera.

Authors:  Claudio Iovino; Valentina Di Iorio; Raffaella Brunetti-Pierri; Michele Lanza
Journal:  Diagnostics (Basel)       Date:  2022-03-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.