| Literature DB >> 34796239 |
Shashank Dwivedi1, Michael Kutschke1, Maheen Nadeem1, Brett D Owens1.
Abstract
BACKGROUND: Distal femoral osteochondral allograft transplantation (OAT) is an effective treatment of osteochondral lesions in the knee measuring >2 cm2 in select patients. Prior studies have demonstrated that the morphology of the plug can affect graft-host interference fit. To our knowledge, there are no data comparing the initial biomechanical stability of standard cylindrical plugs with multiple-plug and oblong-plug morphologies. HYPOTHESIS: Large cylindrical single-plug (LCSP) and oblong single-plug (OSP) grafts will have greater pull-out strength, and therefore greater initial stability, than multiple-plug (MP) grafts in a cadaveric porcine femur model. STUDYEntities:
Keywords: autograft in a porcine model; biomechanics; osteochondral allograft transplantation; stability
Year: 2021 PMID: 34796239 PMCID: PMC8593298 DOI: 10.1177/23259671211044993
Source DB: PubMed Journal: Orthop J Sports Med ISSN: 2325-9671
Dimensions for LCSP, MP, and OSP Plugs and Beds
| Width, mm | Length, mm | Depth/Thickness, mm | |
|---|---|---|---|
| LCSP | |||
| Plug | 20 | 20 | 9.8 |
| Bed | 20.2 | 20.2 | 9.4 |
| MP | |||
| Plug | 15 | 15.1 | 9.4 |
| Bed | 14.8 | 14.8 | 9.9 |
| OSP | |||
| Plug | 14.2 | 30.2 | 12-o’clock: 7.7 |
| Bed | 14.4 | 30.5 | 12-o’clock: 6.5 |
Values are reported as mean values without standard deviation for ease of visualization. LCSP, large cylindrical single plug; MP, multiple-plug; OSP, oblong single-plug.
Thicknesses of the OSP plug and beds were measured in all 4 directions (given as clockface positions).
Figure 1.Morphology of grafts for (A) the OSP and (B) MP grafts. (C) Position of the screw-eye in the multiple-graft configuration. This image also demonstrates the end state of the graft after tensile testing. MP, multiple-plug; OSP, oblong single-plug.
Figure 2.Maximal tensile force needed to induce failure of all 3 graft morphologies and the displacement of the graft at this failure threshold.
Estimated Maximum Load and Displacement at Maximum Load
| Group | Maximum Load, N | Displacement at Maximum Load, mm |
|---|---|---|
| LCSP (n = 18) | 133 (102.9-163.2) | 0.71 (0.52-0.96) |
| MP (n = 18) | 117.6 (93.6-141.6) | 0.60 (0.43-0.83) |
| OSP (n = 19) | 65.7 (51.3-80.1) | 0.44 (0.34-0.56) |
Estimates are reported as mean (95% CI); LCSP and MP each have 1 missing value because of the screw pull-out. LCSP, large cylindrical single-plug; MP, multipleplug; OSP, oblong single-plug.
Pearson Correlation Coefficients Between Maximum Load and Displacement With Bed-Plug Discrepancy
| Maximum Load | Displacement | Discrepancy: Diameter 1 | Discrepancy: Diameter 2 | |
|---|---|---|---|---|
| Maximum load | 1 | |||
| Displacement | — | 1 | ||
| Discrepancy: diameter 1 | 0.06 | –0.18 | 1 | |
| Discrepancy: diameter 2 | –0.03 | –0.12 | — | 1 |
—, no value to report.