Jun Nakayama1, Kosaku Sunagawa1, Kazunori Ogawa2, Hisao Oka3. 1. Department of Allied Health Sciences, Kansai University of Welfare Sciences, Osaka, Japan. 2. Daiya Industrial Inc, Okayama City, Japan. 3. Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama City, Japan.
Abstract
OBJECTIVES: Recently, the dart-throwing motion (DTM) has attracted attention as a functional direction of wrist joint motion. Consequently, we devised a new artificial muscle-type dynamic orthosis (Dynamic Traction Splint by Artificial Muscle, DTSaM) to reproduce DTM. This study analyzed the automatic motion of the wrist joint using a three-dimensional motion analysis system to assess how closely the DTSaM replicates DTM. METHODS: The DTSaM orthosis incorporates two McKibben-type rubber artificial muscles, and measurements were performed using image analysis software and a three-dimensional motion analysis system. The wrist radial angle (WRA) was defined as the angle between the line connecting the head of the index finger metacarpal to the radial styloid process and the line connecting the radial styloid process to the lateral epicondyle of the humerus. WRAs were investigated from 60° of palmar flexion to 60° of dorsiflexion. RESULTS: For dorsiflexion, comparisons of radial deviation and wrist ulnar angle (WUA) between the motion obtained using the DTSaM orthosis and active DTM showed a significant difference (P <0.05) at 30° and 60°, respectively. For palmar flexion, the same comparison showed a significant difference for both the ulnar and radial deviations (30°, P <0.05; and 60°, P <0.01, respectively). Furthermore, WUA showed a significant difference at 50° (P <0.05). Intraclass correlation coefficient analyses yielded good reliability with an average value of ≥0.8. CONCLUSION: The DTSaM orthosis produces a motion similar to the DTM. It is hoped that the use of the DTSaM orthosis will help to shorten the treatment period for patients with wrist disease. 2021 The Japanese Association of Rehabilitation Medicine.
OBJECTIVES: Recently, the dart-throwing motion (DTM) has attracted attention as a functional direction of wrist joint motion. Consequently, we devised a new artificial muscle-type dynamic orthosis (Dynamic Traction Splint by Artificial Muscle, DTSaM) to reproduce DTM. This study analyzed the automatic motion of the wrist joint using a three-dimensional motion analysis system to assess how closely the DTSaM replicates DTM. METHODS: The DTSaM orthosis incorporates two McKibben-type rubber artificial muscles, and measurements were performed using image analysis software and a three-dimensional motion analysis system. The wrist radial angle (WRA) was defined as the angle between the line connecting the head of the index finger metacarpal to the radial styloid process and the line connecting the radial styloid process to the lateral epicondyle of the humerus. WRAs were investigated from 60° of palmar flexion to 60° of dorsiflexion. RESULTS: For dorsiflexion, comparisons of radial deviation and wrist ulnar angle (WUA) between the motion obtained using the DTSaM orthosis and active DTM showed a significant difference (P <0.05) at 30° and 60°, respectively. For palmar flexion, the same comparison showed a significant difference for both the ulnar and radial deviations (30°, P <0.05; and 60°, P <0.01, respectively). Furthermore, WUA showed a significant difference at 50° (P <0.05). Intraclass correlation coefficient analyses yielded good reliability with an average value of ≥0.8. CONCLUSION: The DTSaM orthosis produces a motion similar to the DTM. It is hoped that the use of the DTSaM orthosis will help to shorten the treatment period for patients with wrist disease. 2021 The Japanese Association of Rehabilitation Medicine.
Entities:
Keywords:
dart-throwing motion; hand therapy; motion analyzer; wrist joint angle
Wrist disease causes pain, swelling, and contracture and significantly impairs activities
of daily living and quality of life.[1]) Sequelae associated with wrist joint diseases, such as pain,
often remain; moreover, some patients with wrist joint disorders develop contractures.Contractures are treated by identifying the limiting factors and employing focused
treatment. Sustained stretching is effective for contracted tissue.[2]) The application of dynamic orthoses
is known to be an effective therapy for improving the range of motion.[3]) Similarly, dynamic orthoses are
effective and widely accepted for improving finger function after trauma, and their use is
expected to shorten the treatment period.[4]) Conventional dynamic orthoses for wrist joints[5]) are unidirectional; therefore, there
is a risk of increased pain. Moreover, such orthoses may be ineffective because of the
difficulty in adopting an approach adjusted to the limiting factors.Overall wrist joint movement is essentially the sum of the movements of the carpometacarpal
joint (C-L joint) and the radiocarpal joint (R-L joint).[6]) The movement ratio of these two joints to the movement of
the entire wrist joint is called the contribution ratio. There are characteristic tendencies
in the contribution ratio. In rehabilitation, it is important to improve the contracture of
each joint and to normalize the contribution ratio.[6],[7],[8])
Recently, application of the dart-throwing motion (DTM) to contracted hands has been
studied. DTM exercise is reportedly effective for C-L joints,[9],[10],[11]) suggesting that motion in the DTM plane can be preserved
following wrist surgery, as in radiocarpal fusion, provided that mid-carpal motion is
permitted.[12],[13],[14]) DTM has been shown to require minimal relative
rotation of the scaphoid and lunate.[9],[14],[15],[16]) Therefore, DTM may be permitted during early mobilization
following injury. However, an accurate measurement of DTM is required before it is used in
clinical practice because deviation from the DTM path reportedly increases the relative
motion of the carpal bones.[15])Moreover, the development and clinical effects of dynamic orthoses, including those that
reproduce the DTM, should be considered.[17],[18]) However, to enable active movements, orthoses are usually
made of rigid materials, and this makes them difficult to use when treating diseases such as
contractures that require tissue expansion.Therefore, based on a dynamic orthosis that has a clinical effect on wrist
contracture,[5]) we devised a
new orthodontic orthosis that combines the DTM with traction effects, thereby addressing the
common problems. The resulting orthosis incorporates pneumatic artificial muscles (PAMs),
which generate superior tension as the power source of the straightening action to achieve
traction at the wrist and effective passive DTM. The device is an artificial muscle-type
traction orthosis (novel Dynamic Traction Splint by Artificial Muscle: DTSaM)[19]) developed for exercising the wrist
joint. The authors previously assessed the clinical effects of using the DTSaM orthosis in
patients with painful wrist contracture.[19]) The present study aimed to analyze the automatic motion of
the wrist joint during DTM using three-dimensional motion analysis to assess the accuracy
with which the DTSaM replicates DTM.
MATERIALS AND METHODS
Structure and Characteristics of the DTSaM Orthosis
Figure 1 shows the features and mounting
attachments of the McKibben artificial muscles. The DTSaM includes a controller, a palm
finger cuff, a wrist cuff, a forearm cuff (made by Daiya Industry Co., Ltd., Japan), a
dorsal stay, McKibben artificial muscles (two palms, two dorsals), and elbow joint and
forearm fixtures (thermoplastic Orfit material, produced in-house). The orthosis works by
using PAMs to correct the dorsiflexion and the palmar flexion while performing traction.
The PAMs were arranged such that the rubber tube was constrained by the elastic material
in the longitudinal direction of the finger. In the resulting structure, the rubber tube
expands toward the center point and contracts when pressurized (Fig. 2).
Fig. 1.
Essential parts of the DTSaM wrist orthosis: ① forearm cuff (made by Daiya Industry
Co., Ltd., Japan), ② hand cuff (made by Daiya Industry Co., Ltd., Japan), ③ artificial
muscle for palmar flexion (two), ④ artificial muscle for dorsiflexion (two), and ⑤
controller.
Fig. 2.
Wrist orthosis mechanism for (A) wrist palmar flexion and (B) dorsiflexion. (A) For
palmar flexion, the finger cuff for flexion was attached to the middle and ring
fingers and the wrist cuff was also attached. The pneumatic artificial muscle (PAM)
was attached from the finger cuff to the lateral epicondyle of the humerus. When the
PAM contracted, palmar flexion movement was performed, and the dart-throwing motion
was reproduced. (B) The artificial muscle expands and the dorsal stay of the wrist
joint restricts the movement of the carpal bone and presses the carpal bone in the
volar direction. Thereby, traction is added to the metacarpal bone, and traction and
dorsiflexion of the wrist joint are performed.
Essential parts of the DTSaM wrist orthosis: ① forearm cuff (made by Daiya Industry
Co., Ltd., Japan), ② hand cuff (made by Daiya Industry Co., Ltd., Japan), ③ artificial
muscle for palmar flexion (two), ④ artificial muscle for dorsiflexion (two), and ⑤
controller.Wrist orthosis mechanism for (A) wrist palmar flexion and (B) dorsiflexion. (A) For
palmar flexion, the finger cuff for flexion was attached to the middle and ring
fingers and the wrist cuff was also attached. The pneumatic artificial muscle (PAM)
was attached from the finger cuff to the lateral epicondyle of the humerus. When the
PAM contracted, palmar flexion movement was performed, and the dart-throwing motion
was reproduced. (B) The artificial muscle expands and the dorsal stay of the wrist
joint restricts the movement of the carpal bone and presses the carpal bone in the
volar direction. Thereby, traction is added to the metacarpal bone, and traction and
dorsiflexion of the wrist joint are performed.For palmar flexion, the finger cuff for flexion was attached to the middle finger and the
ring finger and the wrist cuff was also attached. The finger cuff and PAMs were connected,
and the artificial muscles were attached from the finger cuff to the lateral epicondyle of
the humerus. As the PAMs contracted, palmar flexion movement was performed, and DTM was
reproduced (Fig. 2A).For dorsiflexion, the artificial muscle expanded, as shown in Fig. 2 B, and the dorsal stay of the wrist joint restricted the
movement of the carpal bone and pressed the carpal bone in the volar direction.
Consequently, traction was added to the metacarpal bone, and traction and dorsiflexion of
the wrist joint were performed. This traction method is very different from conventional
wrist traction devices. To reproduce DTM, the PAMs were attached, and traction was
initiated to perform the dorsiflexion motion.
Subjects
Twenty healthy forearms from 12 men and 8 women with an average age of 26.2 years (range,
25–28 years) were evaluated. The average forearm height was 162.5 ± 7.8 cm, the body
weight was 70.1 ± 10.1 kg, and all subjects were right-handed. The traction force was
unified and measured at 300 kPa using the PAMs. To avoid affecting the blood flow and
causing pain, the study was conducted after confirming the skin color and assessing
subjective symptoms after the subject had worn the cuff for 3 min.[20],[21]) We previously examined the effects of the
orthosis cuff on blood flow and myoelectrical activity and have proven its
safety.[22]) For the cuff
shape, we used a wrist cuff covering the entire circumference of the wrist to obtain
complete compression on the dorsal and volar arches.[23])This research was approved by the Kansai Welfare Science University Ethics Committee
(Approval number 17–19). Written informed consent was obtained before patient enrollment
from all volunteers who agreed to participate in the research protocol.
Measurement Method
The forearm muscles that are directly involved in generating DTM are the extensor carpi
radialis brevis and longus (ECRL-B) and the flexor carpi ulnaris (FCU).[17]) Therefore, the McKibben-type
rubber artificial muscles were arranged along the running direction of the muscle by
palpating the two palmar sides of the FCU and the two dorsal sides of the ECRL-B. The
wrist joint cuff was made of polyurethane. Care was taken to avoid any deviation between
individuals. We prepared a fixture exclusively for this research to fix the measured limb
position at 90° flexion of the elbow joint and 45° pronation of the forearm. The movement
of the wrist joint was measured using a three-dimensional motion analysis system (Opti
Track Japan: Motive Tracker) and image analysis software (SKYCOM, Japan). Three Flex3
cameras were used for motion capture, and the camera settings were frame rate (FPS) 100,
exposure (EXP) 480, threshold (THR) 255, and LED illumination (LED) 15.The measurement angle of the wrist joint was based on the wrist radial angle (WRA), i.e.,
the angle formed by the line between the index phalanx head and the radial styloid process
and the line between the radial styloid process and the lateral epicondyle of the humerus
(Fig. 3a). The changes in other anatomical
variables were estimated for units of 10° of WRA from 60° of palmar flexion to 60°of
dorsiflexion. We also analyzed the wrist ulnar angle (WUA), i.e., the angle formed by the
line between the phalangeal head of the little finger and the ulnar styloid process and
the line between the ulnar styloid process and the lateral epicondyle of the humerus; the
ulnar deviation (UD), i.e., the angle formed by the line between the phalanx of the index
finger and the radial styloid process and the line between the radial styloid process and
the ulnar styloid process; and the radial deviation (RD) i.e., the angle formed by the
line between the phalangeal head of the little finger and the ulnar styloid process and
the line between the ulnar styloid process and the radial styloid process. Measurements
were taken three times each for the following three scenarios: active exercise, the motion
produced by the DTSaM, and passive exercise performed by a skilled occupational therapist
with more than 10 years of experience with consideration of DTM. The average values were
subsequently measured and calculated.
Fig. 3.
Definition of wrist angles for measurement. (A) Wrist radial angle (WRA): the angle
formed by the line connecting the index finger head of the metacarpal bone to the
styloid process of the radius and the line connecting the lateral epicondylus of the
humerus to the styloid process of the radius. (B) Wrist ulnar angle (WUA): the angle
formed by the line connecting the little finger head of the metacarpal bone to the
styloid process of the ulna and the line from the lateral epicondyle of the humerus to
the styloid process of the ulna. (C) Radial deviation (RD): the angle between the line
connecting the index finger metacarpal head to the styloid process of the radius and
the line connecting the styloid process of the radius to the styloid process of the
ulna. (D) Ulnar deviation (UD): the angle between the line connecting the little
finger head of the metacarpal bone to the styloid process of the ulna and the line
connecting the styloid process of the ulna to the styloid process of the radius.
Definition of wrist angles for measurement. (A) Wrist radial angle (WRA): the angle
formed by the line connecting the index finger head of the metacarpal bone to the
styloid process of the radius and the line connecting the lateral epicondylus of the
humerus to the styloid process of the radius. (B) Wrist ulnar angle (WUA): the angle
formed by the line connecting the little finger head of the metacarpal bone to the
styloid process of the ulna and the line from the lateral epicondyle of the humerus to
the styloid process of the ulna. (C) Radial deviation (RD): the angle between the line
connecting the index finger metacarpal head to the styloid process of the radius and
the line connecting the styloid process of the radius to the styloid process of the
ulna. (D) Ulnar deviation (UD): the angle between the line connecting the little
finger head of the metacarpal bone to the styloid process of the ulna and the line
connecting the styloid process of the ulna to the styloid process of the radius.
Statistical Analysis
Statistical analysis was performed using analysis of variance and Friedman’s test.
Post-tests were performed using Scheffe’s multiple comparison test. Furthermore, the
validity was calculated from the passive motion and the measured values of DTSaM, but not
for active motion, using the intraclass correlation coefficient (ICC).
RESULTS
Dorsiflexion
For dorsiflexion, there were significant differences in WUA between DTSaM and active
exercise for all WRA angles from 10° (P<0.01) to 60° (P<0.05) (Fig. 4). For the same comparison, UD showed significant differences
between 30° and 50° (P<0.05). For RD, significant differences were found at 20°–40°
(P<0.05). For active compared with passive exercise, WUA showed significant differences
between 20° and 60° (P<0.05). UD showed significant differences at all angles from 10°
to 60° (P<0.01, P<0.05), and RD showed significant differences between 20° and 50°
(P<0.05). A comparison of DTSaM and passive movement showed significant differences in
UD at 10° (P<0.05), 20° (P<0.01), 50°, and 60° (P<0.05). For RD, there was a
significant difference at 50° only (P<0.01). The ICC of passive movement and DTSaM for
WUA increased from 0.81 to 0.83; for UD, ICC increased from 0.78 to 0.88, and for RD, ICC
increased from 0.75 to 0.81 (Table 1).
Fig. 4.
Changes in anatomical angles in the dorsiflexion direction for WRA in the range
10°–60°: (A) wrist ulnar angle (WUA), (B) ulnar deviation (UD), and (C) radial
deviation (RD). Analysis of variance and the Friedman test were performed. A post-hoc
test was performed using Scheffe’s multiple comparison test. *P<0.05, †P<0.01.
ROM, range of motion.
Changes in anatomical angles in the dorsiflexion direction for WRA in the range
10°–60°: (A) wrist ulnar angle (WUA), (B) ulnar deviation (UD), and (C) radial
deviation (RD). Analysis of variance and the Friedman test were performed. A post-hoc
test was performed using Scheffe’s multiple comparison test. *P<0.05, †P<0.01.
ROM, range of motion.ICC, intraclass correlation coefficient; CI, confidence interval; WUA, wrist ulnar
angle; RD, radial deviation; UD, ulnar deviation.
Palmar Flexion
For palmar flexion (Fig. 5), there were
significant differences in WUA between DTSaM and active exercise for WRA angles of 10°,
20°, 50°, and 60° (P<0.05). For the same comparison, UD showed significant differences
for all angles in the range 20°–60° (P<0.05). For RD, significant differences were also
found in the range 20°–60° (P<0.05). For active compared with passive movement, WUA
showed significant differences at WRA angles of 10°, 20°, 40°, 50°, and 60° (P<0.05).
UD showed significant differences at all angles from 10° to 60° (P<0.05), and RD showed
significant differences for WRA angles in the range 20°–60° (P<0.05). A comparison of
DTSaM and passive movement showed a significant difference in UD at 10° (P<0.01) and
20° (P<0.05). Additionally, a significant difference was observed in RD at 50°
(P<0.01). The ICCs for passive movement and DTSaM for WUA, UD, and RD were 0.77 to
0.81, 0.75 to 0.77, and 0.77 to 0.81, respectively (Table 1).
Fig. 5.
Changes in (A) WUA, (B) UD, and (C) RD in the palmar flexion direction for WRA in
the range 10°–60°. Analysis of variance and the Friedman test were performed. A
post-hoc test was performed using Scheffe’s multiple comparison test. *P<0.05,
†P<0.01.
Changes in (A) WUA, (B) UD, and (C) RD in the palmar flexion direction for WRA in
the range 10°–60°. Analysis of variance and the Friedman test were performed. A
post-hoc test was performed using Scheffe’s multiple comparison test. *P<0.05,
†P<0.01.
DISCUSSION
We devised a new orthosis that can stretch tissues using a highly flexible clothing
material and PAMs. From our results, no radial or ulnar flexion movements were observed
between WRA angles of 10° and 60° during automatic movements for both flexion and
dorsiflexion. Therefore, even if the pronation position was approximately 45°, the movement
would not be similar to DTM, unless the subject was under instruction.In passive DTM movements, the ulnar flexion angle during palmar flexion and during
dorsiflexion changed by an average of 33.2° and 22.2°, respectively. Under DTSaM, the ulnar
flexion angle during palmar flexion and during dorsiflexion were, on average, 32.3° and
21.4°, respectively. There was a significant difference in both the flexion and dorsiflexion
directions.Early mobilization of the wrist is important to prevent the development of fibrosis and
secondary stiffness and to regain proprioception more quickly, thereby ensuring a faster
return to function. To date, wrist joint motion has been evaluated and analyzed mainly in
two directions: dorsiflexion/palmar flexion and radial/ulnar flexion. However, the motion
from radial dorsiflexion, which is a diagonal movement combining radial flexion and
dorsiflexion, to palmar ulnar flexion (i.e., the DTM) has been recently included in the
analysis.Furthermore, the diagonal movement of ulnar dorsiflexion, which combines ulnar and
dorsiflexion, to radial flexion, which in turn combines radial and palmar flexion, has been
used in functional anatomy.[14],[23]) Cadaveric and in vivo studies demonstrated that both lunate
motion and scaphoid motion are minimal during motion in the true DTM plane.[9],[14],[15]) Early post-surgical rehabilitation of the wrist along a plane
that is not consistent with DTM may result in excessive scaphoid and lunate motion, thereby
compromising the surgical reconstruction. Therefore, the accurate measurement of DTM in the
clinic is important for both clinical assessment and the use of DTM in the design of
rehabilitation tools, such as dynamic orthoses. Such measurement would also facilitate
strengthening programs that allow mobilization of the wrist along the DTM plane
only.[24]) “Dart orthoses”
may be utilized in postoperative rehabilitation protocols wherein it is necessary to
immobilize the radio-carpal joint, such as following surgical repair or reconstruction of
radio-carpal ligaments, scapholunate ligaments, midcarpal instability, and
radioscapho-lunate fusion. Moreover, dart orthoses can be recommended for the conservative
treatment of several types of predynamic and dynamic scapho-lunate interosseous ligament
instability and palmar midcarpal instability. Currently, the basic characteristics of DTM
and the effectiveness of dart orthoses are inconclusive. However, such orthoses need to be
rigid orthotics and should be focused on active motion. Therefore, it is problematic to
apply dart orthoses to diseases such as contractures, which require tissue expansion.Generally, PAMs enable effective treatment to be delivered under conditions of relatively
low pressure and reduced tension; consequently, PAMs were used to provide powered torque for
DTSaM orthoses. Additionally, PAM utilization results in orthoses that are flexible,
lightweight, easily maintained, and inexpensive. Recent studies have quantified in detail
the force-length, force-velocity, force-activation, and bandwidth properties of artificial
pneumatic muscles.[25],[26],[27],[28]) PAMs, which can generate high power at low pressures, are
well suited for mimicking natural gait movements,[26],[27]) as in the current DTSaM orthosis, and for providing
power-assisted gloves.[29])The current DTSaM results are similar to those of a previous study,[30]) and DTM movements may be closely
reproduced. However, it takes time for the artificial muscle to expand after the pressure is
applied to the entire rubber tube. The comparison between passive movement and DTSaM
movement revealed a difference in the radial flexion angle between the palmar flexion and
dorsiflexion motions during the initial motion. However, ICC analyses yielded good
reliability, with an average value of ≥0.8 between WUA, RD, and UD for both dorsiflexion and
palmar flexion in DTSaM movement and passive movement. Consequently, the DTSaM orthosis may
enable reproduction of the DTM movement. The results of the current study are novel in that
we developed an orthosis with a movement similar (as judged by optical motion capture) to
the DTM performed by skilled occupational therapists in previous studies.This study has several limitations. First, the research was conducted in healthy young
individuals and did not include elderly or disabled persons; therefore, the feasibility of
its application in the clinical setting should be examined. Second, the neutral position of
the range of motion in the 90° pronation condition cannot be defined theoretically, and the
measurements may be inappropriate for high pronation angles. Third, while intra-rater
reliability was evaluated, inter-rater reliability could not be assessed. Therefore, the
characteristics and biases of the examiner may be reflected in the data. In the future, it
will be important to compare DTSaM to conventional orthoses, to evaluate inter-examiner
reliability in terms of the feel and ease of wearing the orthoses, and to obtain results
based on sound scientific evidence. Furthermore, we would like to examine the clinical
effect of using the DTSaM to treat patients with contractures and deformities. Moreover, the
durability of the equipment has not been examined. It will be necessary to investigate the
degree of fatigue of the McKibben rubber tube in relation to air pressure and the strength
of the cuff.
CONCLUSION
The DTSaM orthosis reproduces a motion similar to the DTM. It is hoped that the use of
DTSaM orthoses will contribute significantly to shortening the treatment period for patients
with wrist disease.
Authors: Joseph J Crisco; James C Coburn; Douglas C Moore; Edward Akelman; Arnold-Peter C Weiss; Scott W Wolfe Journal: J Bone Joint Surg Am Date: 2005-12 Impact factor: 5.284
Authors: Ryan P Calfee; Evan L Leventhal; Jim Wilkerson; Douglas C Moore; Edward Akelman; Joseph J Crisco Journal: J Hand Surg Am Date: 2008-04 Impact factor: 2.230