Literature DB >> 34781997

Continuous wireless postoperative monitoring using wearable devices: further device innovation is needed.

William Xu1, Armen A Gharibans2, Ian P Bissett3, Gregory O'Grady3,2, Cameron I Wells3,2, Carlos Areia, Christopher Biggs, Mauro Santos, Neal Thurley, Stephen Gerry, Lionel Tarassenko, Peter Watkinson, Sarah Vollam.   

Abstract

Entities:  

Mesh:

Year:  2021        PMID: 34781997      PMCID: PMC8594168          DOI: 10.1186/s13054-021-03805-0

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


× No keyword cloud information.
To the editor, We read with great interest the recent article by Areia et al. which highlights the current lack of evidence surrounding the use of wearable monitoring systems to detect deterioration in hospitalised patients. We agree with the authors’ conclusion that the variety of designs, populations, outcomes, and devices “makes it difficult to reach a definitive conclusion”. We also agree that this is an emerging area needing further research. In this meta-analysis, three small randomised controlled trials (RCTs) were included. These RCTS utilised two different devices, the SensiumVitals (The Surgical Company, UK), and the Isansys Lifetouch (Isansys Lifecare, UK) devices. The limited precision of both devices has been noted previously [1, 2]. Other clinical validation studies of wearable monitoring devices have also demonstrated limited device precision in the postoperative setting [3]. Therefore, any assessment of the ability for devices to detect early deterioration is heavily confounded by inherent limitations of the devices. The possibility for wireless continuous monitoring cannot be realised until the devices used are sufficiently accurate and precise. Despite the breadth of devices in this field, most wireless continuous monitoring devices are still in their clinical validation phases [4]. The most immediate challenge in this field is the need for more accurate devices, which needs to be solved through further innovation. Large, well-powered RCTs should not be conducted until robust clinical validation studies have demonstrated adequate device accuracy and precision. Validation studies should also consider the use of continuous monitors as a reference standard rather than nurse-measured observations which are limited in both their frequency and potential accuracy. Wireless continuous vital signs monitoring likely has benefits that are yet to be apparent. Undetected hypotension, hypoxemia and respiratory depression in the postoperative patient is common and often prolonged; delayed detection of these physiological changes may be a significant contributor to ‘failure-to-rescue’ and postoperative death [5]. Systems that allow for better detection of patient deterioration have the potential to significantly improve patient care, and rigorous work should be done to explore avenues for improvement. Accurate artefact rejection, better signal processing, and novel sensor technology all may improve device accuracy and utility. The work of Areia et al. has highlighted the need for further innovations in this space. Device improvements and clinical validation work will shed light on the true value of continuous postoperative monitoring and, most importantly, help confirm if this technology can improve patient outcomes. We would like to thank Xu et al. for their interest in our recent manuscript. We agree most devices are still in their feasibility and clinical validation stage, with limited evidence on their clinical and cost effectiveness, highlighted in our review and previous research [4]. It is important to consider that the goal of this emerging technology should be to support, and not replace, clinical vital sign monitoring practice, offering another layer of protection between traditional continuous monitoring and manual intermittent observations. Furthermore, although accuracy and reliability of wearable devices are a barrier, most studies have been conducted in healthy volunteers and in comparison with clinical and/or gold standard for continuous measurement [4]; with even less evidence comparing these devices with the standard intermittent manual measurements, the common practice in general wards. We agree with our colleagues these new monitoring systems should not be used as the “stand-alone” method of vital sign measurement, due to current accuracy and precision limitations. However, well-powered and well-designed clinical trials, including careful implementation of these new systems, might still be of benefit to support the development and innovation of these technologies, by testing its impact in clinical care as complementary, and not a substitute, to standard practice [6].
  6 in total

1.  Beyond 'failure to rescue': the time has come for continuous ward monitoring.

Authors:  Daniel I Sessler; Bernd Saugel
Journal:  Br J Anaesth       Date:  2019-01-03       Impact factor: 9.166

2.  Continuous vital sign monitoring after major abdominal surgery-Quantification of micro events.

Authors:  C L Duus; E K Aasvang; R M Olsen; H B D Sørensen; L N Jørgensen; M P Achiam; C S Meyhoff
Journal:  Acta Anaesthesiol Scand       Date:  2018-07-02       Impact factor: 2.105

3.  Reliability of a wearable wireless patch for continuous remote monitoring of vital signs in patients recovering from major surgery: a clinical validation study from the TRaCINg trial.

Authors:  Candice Downey; Shu Ng; David Jayne; David Wong
Journal:  BMJ Open       Date:  2019-08-15       Impact factor: 2.692

4.  Experiences of current vital signs monitoring practices and views of wearable monitoring: A qualitative study in patients and nurses.

Authors:  Carlos Areia; Elizabeth King; Jody Ede; Louise Young; Lionel Tarassenko; Peter Watkinson; Sarah Vollam
Journal:  J Adv Nurs       Date:  2021-10-15       Impact factor: 3.057

5.  Reliability of wireless monitoring using a wearable patch sensor in high-risk surgical patients at a step-down unit in the Netherlands: a clinical validation study.

Authors:  Martine J M Breteler; Erik Huizinga; Kim van Loon; Luke P H Leenen; Daan A J Dohmen; Cor J Kalkman; Taco J Blokhuis
Journal:  BMJ Open       Date:  2018-02-27       Impact factor: 2.692

6.  Current Evidence for Continuous Vital Signs Monitoring by Wearable Wireless Devices in Hospitalized Adults: Systematic Review.

Authors:  Jobbe P L Leenen; Crista Leerentveld; Joris D van Dijk; Henderik L van Westreenen; Lisette Schoonhoven; Gijsbert A Patijn
Journal:  J Med Internet Res       Date:  2020-06-17       Impact factor: 5.428

  6 in total
  2 in total

Review 1.  The impact of continuous wireless monitoring on adverse device effects in medical and surgical wards: a review of current evidence.

Authors:  Eske K Aasvang; Christian S Meyhoff; Nikolaj Aagaard; Arendse Tange Larsen
Journal:  J Clin Monit Comput       Date:  2022-08-02       Impact factor: 1.977

Review 2.  Wearable devices to monitor recovery after abdominal surgery: scoping review.

Authors:  Cameron I Wells; William Xu; James A Penfold; Celia Keane; Armen A Gharibans; Ian P Bissett; Greg O'Grady
Journal:  BJS Open       Date:  2022-03-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.