Literature DB >> 34780390

Third-Generation Ceramic-on-Ceramic Total Hip Arthroplasty in Patients with Osteonecrosis of the Femoral Head: A 10- to 16-year Follow-up Study.

Hong Seok Kim1, Jung Wee Park2, Joo Hyung Ha2, Young-Kyun Lee2,3, Yong-Chan Ha4, Kyung-Hoi Koo2,3.   

Abstract

BACKGROUND: Long-term follow-up results of ceramic-on-ceramic (COC) total hip arthroplasty (THA), specifically, in patients with osteonecrosis of the femoral head (ONFH) are unknown. We evaluated (1) clinical results and radiological outcomes, (2) ceramic-related complications: noise and ceramic fracture, (3) osteolysis, and (4) survivorship after alumina COC THA in ONFH patients with longer than 10-year follow-up.
METHODS: From May 2003 to June 2009, 325 ONFH patients (403 hips) underwent primary THAs at our department. Among them, 231 patients (293 THAs) were followed for 10 to 16 (mean, 12.9) years. There were 148 men and 83 women, their mean age at the time of THA was 47.2 years, and their mean body index was 24.0 kg/m2. The postoperative CT scans were done in 160 hips.
RESULTS: Grinding sensation or squeak was noted in 6.8% (20/293), ceramic head fracture occurred in 2.4% (7/293) and acetabular osteolysis developed in 0.7% (2/293). All 7 ceramic fractures occurred in 28-mm short-neck heads. There was no detectable wear or prosthetic loosening, and the 16-year survivorship was 96.0% (95% confidence interval; 93.8% to 98.2%). The mean Harris hip score was 91.7 (range, 84 to 100) points at the final follow-up.
CONCLUSIONS: The 10- to 16-year results of alumina COC THAs were encouraging with an excellent survivorship. However, ceramic fracture and noise still remain matters of concern. We recommend not to use 28-mm short-neck ceramic head to avoid ceramic head fractures. LEVEL OF EVIDENCE: III.
Copyright © 2021 by The Journal of Bone and Joint Surgery, Incorporated.

Entities:  

Mesh:

Substances:

Year:  2022        PMID: 34780390     DOI: 10.2106/JBJS.20.00720

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  2 in total

1.  Hip function in patients undergoing conservative treatment for osteonecrosis of the femoral head.

Authors:  Yusuke Osawa; Yasuhiko Takegami; Daisaku Kato; Masanori Okamoto; Hiroki Iida; Shiro Imagama
Journal:  Int Orthop       Date:  2022-09-14       Impact factor: 3.479

2.  The Wear Rate and Survivorship in Total Hip Arthroplasty Using a Third-generation Ceramic Head on a Conventional Polyethylene Liner: A Minimum of 15-year Follow-up.

Authors:  Bum-Jin Shim; Sung-Jin Park; Chan Ho Park
Journal:  Hip Pelvis       Date:  2022-06-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.