Helen Eftekhari1, Hejie He1, James Doug Lee2, Geeta Paul2, Albiona Zhupaj2, Thomas Lachlan1, Michael Kuehl1, Tarv Dhanjal1, Sandeep Panikker2, Shamil Yusuf2, Sajad Hayat2, Faizel Osman3. 1. Department of Cardiology, University Hospitals Coventry & Warwickshire NHS Trust, Coventry, United Kingdom; Warwick Medical School, University of Warwick, Coventry, United Kingdom. 2. Department of Cardiology, University Hospitals Coventry & Warwickshire NHS Trust, Coventry, United Kingdom. 3. Department of Cardiology, University Hospitals Coventry & Warwickshire NHS Trust, Coventry, United Kingdom; Warwick Medical School, University of Warwick, Coventry, United Kingdom. Electronic address: faizel.osman@uhcw.nhs.uk.
Abstract
BACKGROUND: Implantable loop recorders (ILRs) are effective in achieving symptom-rhythm correlation. Data on the diagnostic yield of ILRs, on nurse-led syncope clinics, and on nurse-led ILR implants are limited. OBJECTIVE: We evaluated the safety and efficacy of our nurse-led syncope clinic and nurse-led ILR implants. METHODS: A retrospective study of all consecutive patients undergoing nurse-led ILR implantations was performed between April 2016 and April 2018. Patients were referred from both nurse-led and physician-led clinics. Data were collected on baseline demographic characteristics, referral source, symptom-rhythm correlation, ILR findings, and subsequent changes to management. All ILRs were enrolled into remote monitoring with automatic arrhythmia detection, and all immediate (≤24 hours) ILR implant complications were recorded. Comparisons were made between nurse-led and physician-led clinics and subsequent outcomes. RESULTS: A total of 432 patients with an ILR were identified: 164 (38%) from nurse-led and 268 (62%) from physician-led clinics; 200 (46%) were women (mean age 66.5 ± 18.2 years; mean follow-up duration 28.9 ± 9.5 months). Primary ILR indications were syncope (n = 251 [58%]), presyncope (n = 33 [7%]), palpitation (n = 39 [9%]), cryptogenic stroke (n = 78 [18%]), and other reasons (n = 31 [7%]). No immediate ILR implant complications occurred. Overall, 156 patients (36%) had a change in management as a direct result of ILR findings, with no overall differences between nurse-led and physician-led clinics (35% vs 36%; P = .7). More patients had newly diagnosed atrial fibrillation in physician-led clinics (15% vs 7%; P = .01), and more patients had pacemaker implants for bradycardia in nurse-led clinics (23% vs 13%; P < .01). CONCLUSION: Nurse-led ILR implantation was safe and effective. Nurse-led syncope clinics achieved good symptom-rhythm correlation with resultant significant changes to management in comparison to physician-led clinics. Larger prospective studies are needed to evaluate their longer-term impact.
BACKGROUND: Implantable loop recorders (ILRs) are effective in achieving symptom-rhythm correlation. Data on the diagnostic yield of ILRs, on nurse-led syncope clinics, and on nurse-led ILR implants are limited. OBJECTIVE: We evaluated the safety and efficacy of our nurse-led syncope clinic and nurse-led ILR implants. METHODS: A retrospective study of all consecutive patients undergoing nurse-led ILR implantations was performed between April 2016 and April 2018. Patients were referred from both nurse-led and physician-led clinics. Data were collected on baseline demographic characteristics, referral source, symptom-rhythm correlation, ILR findings, and subsequent changes to management. All ILRs were enrolled into remote monitoring with automatic arrhythmia detection, and all immediate (≤24 hours) ILR implant complications were recorded. Comparisons were made between nurse-led and physician-led clinics and subsequent outcomes. RESULTS: A total of 432 patients with an ILR were identified: 164 (38%) from nurse-led and 268 (62%) from physician-led clinics; 200 (46%) were women (mean age 66.5 ± 18.2 years; mean follow-up duration 28.9 ± 9.5 months). Primary ILR indications were syncope (n = 251 [58%]), presyncope (n = 33 [7%]), palpitation (n = 39 [9%]), cryptogenic stroke (n = 78 [18%]), and other reasons (n = 31 [7%]). No immediate ILR implant complications occurred. Overall, 156 patients (36%) had a change in management as a direct result of ILR findings, with no overall differences between nurse-led and physician-led clinics (35% vs 36%; P = .7). More patients had newly diagnosed atrial fibrillation in physician-led clinics (15% vs 7%; P = .01), and more patients had pacemaker implants for bradycardia in nurse-led clinics (23% vs 13%; P < .01). CONCLUSION: Nurse-led ILR implantation was safe and effective. Nurse-led syncope clinics achieved good symptom-rhythm correlation with resultant significant changes to management in comparison to physician-led clinics. Larger prospective studies are needed to evaluate their longer-term impact.