Literature DB >> 34763153

Development of a peptide aptamer pair-linked rapid fluorescent diagnostic system for Zika virus detection.

Anh Thi Viet Nguyen1, Bao Tuan Duong1, Hyun Park1, Seon-Ju Yeo2.   

Abstract

A rapid diagnostic system employing an antigen detection biosensing method is needed to discriminate between Zika virus (ZIKV) and Dengue virus (DENV) due to their close antigenic homology. We developed a novel peptide pair-based flow immunochromatographic test strip (FICT) assay to detect ZIKV. Peptide aptamers, P6.1 (KQERNNWPLTWT), P29.1 (KYTTSTLKSGV), and B2.33 (KRHVWVSLSYSCAEA) were designed by paratopes and modified against the ZIKV envelope protein based on the binding affinity. An antibody-free lateral FICT was developed using a pair of peptide aptamers. In the rapid diagnostic strip, the limit of detection (LOD) for the B2.33-P6.1 peptide pair for ZIKV was 2 × 104 tissue culture infective dose TCID50/mL. Significantly, FICT could discriminate ZIKV from DENV. The stability and performance of FICT were confirmed using human sera and urine, showing a comparable LOD value. Our study demonstrated that in silico modeling could be used to develop a novel peptide pair-based FICT assay for detecting ZIKV by a rapid diagnostic test.
Copyright © 2021. Published by Elsevier B.V.

Entities:  

Keywords:  Antibody-free peptide pair-linked rapid diagnostic system; Biosensor; Peptide aptamer; Zika virus

Mesh:

Substances:

Year:  2021        PMID: 34763153     DOI: 10.1016/j.bios.2021.113768

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Development of a Rapid Fluorescent Diagnostic System for Early Detection of the Highly Pathogenic Avian Influenza H5 Clade 2.3.4.4 Viruses in Chicken Stool.

Authors:  Bao-Tuan Duong; Duc-Duong Than; Bae-Gum Ju; Thuy-Tien Thi Trinh; Chris-Ka Pun Mok; Ju-Hwan Jeong; Min-Suk Song; Yun-Hee Baek; Hyun Park; Seon-Ju Yeo
Journal:  Int J Mol Sci       Date:  2022-06-04       Impact factor: 6.208

2.  Selection of DNA aptamer and its application as an electrical biosensor for Zika virus detection in human serum.

Authors:  Goeun Park; Myoungro Lee; Jiatong Kang; Chulwhan Park; Junhong Min; Taek Lee
Journal:  Nano Converg       Date:  2022-09-10

3.  A New Method for Abrin Detection Based on the Interaction between Target Molecules and Fluorescently Labeled Aptamers on Magnetic Microspheres.

Authors:  Zhiwei Liu; Zhaoyang Tong; Yuting Wu; Bing Liu; Shasha Feng; Xihui Mu; Jiang Wang; Bin Du; Jianjie Xu; Shuai Liu
Journal:  Materials (Basel)       Date:  2022-10-08       Impact factor: 3.748

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.