| Literature DB >> 34760591 |
Lok Yu Wong1, Marc L C Yang1, Hei Jim Leung1, Chi Shing Pak1.
Abstract
OBJECTIVES: (1) To study the dimensions of cricothyroid membranes (CTMs) in healthy Chinese adults in two neck positions, one with rigid neck collar (RNC) and neck extended by ultrasonography (USG). (2) To evaluate how body habitus and neck positions may affect the access time of CTMs, and thus the feasibility for ultrasound-guided cricothyroidotomy.Entities:
Keywords: airway; cricothyroidotomy; emergency department; pocus; trauma
Year: 2019 PMID: 34760591 PMCID: PMC8411669 DOI: 10.1002/ajum.12187
Source DB: PubMed Journal: Australas J Ultrasound Med ISSN: 1836-6864
Figure 1(a) Neck in extension. (b) Neck with an RNC applied.
Figure 2(a) Ultrasound image showing the transverse view of the CTM. (b) The CTM is seen as a white horizontal line formed at the mucosa–air interface (red arrow). White lines deep to the CTM are reverberation artefacts (green arrow). (c) Depth and width of the CTM are measured as shown.
Figure 3(a) Ultrasound image showing the longitudinal view of the CTM. (b) The CTM is seen as a white horizontal line formed at the mucosa–air interface (red arrow). Tracheal rings are shown in blue ovals. Cephalically, the CTM is bound by the inferior edge of the thyroid cartilage (green oval), while caudally, the CTM is bound by the superior border of the cricoid cartilage (red oval). The length of the CTM is measured between these borders.
The biological characteristics of the subjects.
| Variables | Whole cohort (N = 39) |
|---|---|
| Age (median/IQR) | 32 (22–42) |
| Male (%) | 30 (77%) |
| Weight/kg (median/IQR) | 65 (55.5–74.5) |
| Height/cm (mean/SD) | 168.8 ± 8.2 |
| BMI/kg/m2 (mean/SD) | 23.2 ± 4 |
| Neck circumference/cm (mean/SD) | 35 ± 4.3 |
CTM, cricothyroid membrane; BMI, body mass index; SD, standard deviation; IQR, interquartile range.
The CTM dimensions and image acquisition times.
| With neck extended | With neck collar | P‐value | |
|---|---|---|---|
| CTM depth/mm (mean ± SD) | 5.6 ± 1.52 | 5.97 ± 1.61 | 0.04 |
| CTM length/mm (mean ± SD) | 10.5 ± 2.15 | 9.97 ± 2.24 | 0.028 |
| CTM width/mm (mean ± SD) | 7.35 ± 1.62 | 7.20 ± 1.49 | 0.544 |
| Time to image acquisition/seconds (median/IQR) | 6.36 (2.32–8.4) | 5.60 (3.71–7.49) | 0.539 |
CTM, cricothyroid membrane; SD, standard deviation; IQR, interquartile range.
Paired‐sample t‐test.
Wilcoxon sign‐rank test.
Linear regression results.
| Linear regression | ||||||
|---|---|---|---|---|---|---|
| Depth of CTM | Length of CTM | Width of CTM | ||||
| Coefficients | p‐value | Coefficients | P‐value | Coefficients | P‐value | |
| Neck extended | ||||||
| Age | Not in model | Not in model | Not in model | |||
| Male | Not in model | 3.6 | <0.0005 | Not in model | ||
| Weight/kg | 0.08 | <0.0005 | Not in model | Not in model | ||
| Height/cm | −0.09 | <0.0005 | Not in model | Not in model | ||
| Neck Circumference/cm | 0.12 | 0.09 | −0.2 | 0.03 | Not in model | |
| R square of model | 0.74 | 0.298 | ||||
| With neck collar | ||||||
| Age | Not in model | Not in model | −0.5 | 0.014 | ||
| Male | Not in model | 2.92 | <0.0005 | 1.22 | 0.02 | |
| Weight/kg | 0.074 | <0.0005 | Not in model | Not in model | ||
| Height/cm | −0.08 | 0.001 | Not in model | Not in model | ||
| Neck circumference/cm | 0.146 | 0.005 | Not in model | Not in model | ||
| R square of model | 0.691 | 0.31 | 0.268 | |||