Retained foreign needle in the thoracic spinal canal in a child: Case report.

Sarah Kawtharani1, Shadi Abdelatif Bsat1, Mohamad El Houshiemy1, Charbel Moussalem1, Adham Halaoui1, Ibrahim Omeis1.   

Abstract

BACKGROUND: The presence of retained foreign bodies in the spinal canal has been reported in the literature. They are attributed to retained pieces of medical equipment after surgery, or, following trauma, to residual bullets, glass fragments, or knife blades. Although some retained materials do not cause any neurological deficits in the short run, others may become symptomatic months later. CASE DESCRIPTION: A 2-year-old male presented with a history of intermittent fever and mild lower extremity weakness. Notably, the original infectious workup was negative. However, a noncontrast CT scan later documented a needle-shaped foreign body in the spinal canal at the T10 level. During the T10 laminectomy, a needle (i.e. from a medical syringe) was removed, the patient remained neurologically intact. The foreign body turned out to be a medical syringe needle tip.
CONCLUSION: A 2-year-old male presented with fevers and mild lower extremity weakness attributed to an intraspinal needle tip found utilizing CT at the T10 level. T10 laminectomy allowed for removal of a small needle tip. This shows the importance of removing retained spinal foreign bodies to avoid further/future neurological injury, and/or the potential risks/complications of foreign body migration/sequestration. Copyright:
© 2021 Surgical Neurology International.

Entities:  

Keywords:  CT myelography; CT spine; Pediatric; Retained foreign body; Spinal needle

Year:  2021        PMID: 34754534      PMCID: PMC8571406          DOI: 10.25259/SNI_755_2021

Source DB:  PubMed          Journal:  Surg Neurol Int        ISSN: 2152-7806


INTRODUCTION

The presence of retained foreign bodies in the spinal canal has been reported in the literature. They have been attributed to retained pieces of medical equipment after surgery, or after trauma, to retained bullets, glass fragments, or knife blades. Some of the retained material did not cause any neurological deficits in the short run, while others may contribute to new deficits months later.

CASE PRESENTATION

A 2-year-old male presented with fevers, leukocytosis (studies were only positive for leukocytosis with WBC of 179,000/cu.mm), and mild lower extremity weakness. The thoracic CT scan showed a needle-shaped foreign body in the spinal canal at the level of T10 level [Figure 1].
Figure 1:

CT Chest and Abdomen bone window showing Linear radio-opaque foreign body in the spinal canal at the level of the T10 vertebra traversing from the right pedicle to the left neural foramen.

CT myelography documented the presence of a linear radiopaque foreign body (likely a pin/ needle) in the spinal canal at the T10 level traversing from the right pedicle to the left neural foramen; it appeared to be traversing the anterolateral aspect of the cord with no clear contrast separating it from the cord. CT Chest and Abdomen bone window showing Linear radio-opaque foreign body in the spinal canal at the level of the T10 vertebra traversing from the right pedicle to the left neural foramen. The patient underwent a T10 laminectomy for removal of the foreign body that proved to be a medical syringe needle tip [Figure 2]. As the needle traversed the spinal canal, intraoperative monitoring including motor evoked potentials was utilized. There were no significant intraoperative changes. Indeed, postoperatively, the patient’s mild lower extremity weakness resolved progressively after 2-week follow-up and his gait improved after 6 weeks from OR date.
Figure 2:

Intraoperative view showing the spinal needle.

Intraoperative view showing the spinal needle.

DISCUSSION

It has been reported that foreign bodies as needles or wires can migrate into the spinal canal over time and cause nerve injuries.[5] Retaining them for longer periods can cause reactive tissue that can lead to neurological deficits that occur when the neural elements around the foreign body are no longer capable of adjusting to the new changes caused by the presence of this material, thus rendering the need for surgical removal.[4] However, in some reported cases, after failed surgical attempts, the foreign fragment remained retained in the spinal canal with no neurological complications on continuous follow-up appointments.[2] It was found out that the “spring phenomenon” could push foreign bodies to penetrate into intradural space advancing the object closer to the cord or nerve roots.[1] Several cases were also reported of spinal foreign body granulomas from retained pieces of surgical instruments in the paravertebral soft tissues and extramedullary space, which are sometimes confused with neoplasm.[3] CT and radiographs are considered the first line imaging modalities when dealing with acute penetrating injury or suspected metallic foreign body, although MR has been shown to be a safe option.[3] However, MR can fail to show the foreign body when it is small or nonferromagnetic.[3] According to most of the reported case reports in the literature, it was opted to remove foreign bodies surgically to avoid any future damage to the cord or neural elements. Here, we chose surgical intervention after documenting the presence of the foreign body on imaging studies (i.e. CT scan and CT myelogram).

CONCLUSION

A 2-year-old male presented with fever, leukocytosis, and mild lower extremity weakness. Although the infectious workup was negative, the noncontrast CT documented a metallic foreign body at the T10 level that was removed; it proved to be an entrapped spinal medical needle tip. Here, we highlight the importance of removing retained spinal foreign bodies to avoid future long-term neurological injury or foreign body migration.
  5 in total

1.  Thorn in My Spine: A case of a retained intradural extramedullary foreign body.

Authors:  Nakul Reddy; Peter Fata; Anthony Balzer; Pedro Diaz-Marchan; Christie M Lincoln
Journal:  Clin Imaging       Date:  2017-05-18       Impact factor: 1.605

2.  Delayed effects from retained foreign bodies in the spine and spinal cord.

Authors:  W Q Wu
Journal:  Surg Neurol       Date:  1986-03

3.  A glass foreign body migrating into the lumbar spinal canal: a case report.

Authors:  Katsuhito Yoshioka; Norio Kawahara; Hideki Murakami; Satoru Demura; Masaki Matsuda; Katsuro Tomita
Journal:  J Orthop Surg (Hong Kong)       Date:  2012-08       Impact factor: 1.118

4.  Migration of titanium cable into spinal cord and spontaneous C2 and C3 fusion: Case report of possible causes of fatigue failure after posterior atlantoaxial fixation.

Authors:  Huibo Li; Jigang Lou; Hao Liu
Journal:  Medicine (Baltimore)       Date:  2016-12       Impact factor: 1.889

5.  Entrapment of a metal foreign body in the cervical spinal canal during surgical procedure: A case report.

Authors:  Xiaoqiang Lv; Xuan Lu; Yue Wang
Journal:  Medicine (Baltimore)       Date:  2018-04       Impact factor: 1.889

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.