Literature DB >> 34747764

When echocardiography fails, intravascular ultrasound as an alternative for adequate graft patency in hybrid elephant trunk surgery.

Fnu Thida1, Tomas Carvajal2, Shinya Unai3, Sergio E Bustamante4.   

Abstract

Aortic pathology is a common cardiovascular disease in the US. Transesophageal Echocardiogram is an invaluable imaging modality in the management of aortic pathology in perioperative setting. Intravascular ultrasound can assess coronary obstruction during coronary interventions and can be used in endovascular aneurysm repair. A 54-year-old male underwent Hybrid Elephant Trunk Surgery, for complex open aorta repair. There was functional confirmation graft patency via the femoral arterial line tracing, there was surgical confirmation via visual and physical inspection of graft, but there was lacking anatomical confirmation. Epiaortic ultrasound reassured the graft patency at level of the arch. However, transesophageal echocardiogram was not reassuring for adequate anatomical confirmation of patency. Intravascular ultrasound was used for anatomical confirmation of graft patency and position. This technology provides real time graft patency and is a great tool in open aorta reconstruction surgery.

Entities:  

Keywords:  Aorta surgery; elephant trunk surgery; intravascular ultrasonography; transesophageal echocardiography

Mesh:

Year:  2021        PMID: 34747764      PMCID: PMC8617390          DOI: 10.4103/aca.ACA_131_20

Source DB:  PubMed          Journal:  Ann Card Anaesth        ISSN: 0971-9784


  5 in total

Review 1.  Using IVUS during EVAR and TEVAR: improving patient outcomes.

Authors:  Benjamin J Pearce; William D Jordan
Journal:  Semin Vasc Surg       Date:  2009-09       Impact factor: 1.000

Review 2.  Advances in the diagnosis of acute aortic syndromes: Role of imaging techniques.

Authors:  Marco Matteo Ciccone; Ilaria Dentamaro; Filippo Masi; Santa Carbonara; Gabriella Ricci
Journal:  Vasc Med       Date:  2016-03-08       Impact factor: 3.239

3.  A retrospective study of intravascular ultrasound use in patients undergoing endovascular aneurysm repair: its usefulness and a description of the procedure.

Authors:  K Hoshina; M Kato; T Miyahara; A Mikuriya; N Ohkubo; T Miyata
Journal:  Eur J Vasc Endovasc Surg       Date:  2010-08-23       Impact factor: 7.069

Review 4.  Acute aortic syndromes: definition, prognosis and treatment options.

Authors:  S W Carpenter; Y V Kodolitsch; E S Debus; S Wipper; N Tsilimparis; A Larena-Avellaneda; H Diener; T Kölbel
Journal:  J Cardiovasc Surg (Torino)       Date:  2014-04       Impact factor: 1.888

5.  Intravascular Ultrasound-Guidance Is Associated With Lower Cardiovascular Mortality and Myocardial Infarction for Drug-Eluting Stent Implantation - Insights From an Updated Meta-Analysis of Randomized Trials.

Authors:  Islam Y Elgendy; Ahmed N Mahmoud; Akram Y Elgendy; Gary S Mintz
Journal:  Circ J       Date:  2019-04-26       Impact factor: 2.993

  5 in total