Literature DB >> 34739717

Microfluidic chip connected to porous microneedle array for continuous ISF sampling.

Kai Takeuchi1,2, Nobuyuki Takama3, Kirti Sharma4,5, Oliver Paul4,5, Patrick Ruther4,5, Tadatomo Suga6, Beomjoon Kim3.   

Abstract

Minimally invasive biosensing using microneedles (MNs) is a desirable technology for continuous healthcare monitoring. Among a wide range of MNs, porous MNs are expected to be applied for sampling of interstitial fluids (ISF) by connecting the internal tissue to external measurement devices. In order to realize a continuous measurement of biomarkers in ISF through porous MNs, their integration with a microfluidic chip is a promising approach due to its applicability to micro-total analysis system (μTAS) technology. In this study, we developed a fluidic system to directly interface porous MNs to a microfluidic chip consisting of a capillary pump for the continuous sampling of ISF. The porous and flexible MNs made of PDMS are connected to the microfluidic chip fabricated by standard microelectro-mechanical system (MEMS) processes, showing a continuous flow of phosphate buffered saline (PBS). The developed device will lead to the minimally invasive and continuous biosampling for long-term healthcare monitoring.
© 2021. Controlled Release Society.

Entities:  

Keywords:  Biosensing; Glucose monitoring; Microchannel; Microneedle

Mesh:

Year:  2021        PMID: 34739717     DOI: 10.1007/s13346-021-01050-0

Source DB:  PubMed          Journal:  Drug Deliv Transl Res        ISSN: 2190-393X            Impact factor:   4.617


  4 in total

1.  Fabrication of pure-drug microneedles for delivery of montelukast sodium.

Authors:  Erkan Azizoglu; Ozgen Ozer; Mark R Prausnitz
Journal:  Drug Deliv Transl Res       Date:  2021-09-03       Impact factor: 4.617

Review 2.  Microneedle-Based Device for Biological Analysis.

Authors:  Huiting Lu; Shah Zada; Lingzhi Yang; Haifeng Dong
Journal:  Front Bioeng Biotechnol       Date:  2022-04-21

Review 3.  Recent Advances of Microneedles and Their Application in Disease Treatment.

Authors:  Wenjing Zhang; Wei Zhang; Cairong Li; Jianhua Zhang; Ling Qin; Yuxiao Lai
Journal:  Int J Mol Sci       Date:  2022-02-22       Impact factor: 5.923

4.  Anti-SARS-CoV-2 IgM/IgG antibodies detection using a patch sensor containing porous microneedles and a paper-based immunoassay.

Authors:  Leilei Bao; Jongho Park; Boyu Qin; Beomjoon Kim
Journal:  Sci Rep       Date:  2022-07-01       Impact factor: 4.996

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.