Weiyan Ren1, Mingzheng Zhang1, Hongmei Liu2, Yih-Kuen Jan3,4, Fang Pu3, Yubo Fan1,2,3,5.
Abstract
Objectives: Foot ulcers often occur in people with diabetes because of pressure-induced tissue ischemia. Vibration has been reported to be helpful in alleviating mechanical damage and promoting wound healing. The objective of this study is to explore whether vibration can relieve reactive hyperemia in foot tissue under occlusive compression.Entities:
Mesh:
Year: 2021 PMID: 34733455 PMCID: PMC8560250 DOI: 10.1155/2021/6208499
Source DB: PubMed Journal: J Healthc Eng ISSN: 2040-2295 Impact factor: 2.682
Figure 1Test setup for applying pressure and vibration to the whole foot and measuring skin blood flow of the dorsum of foot.
Figure 2Typical example of the variation in skin blood flow during the baseline and the recovery stage with and without vibration in two tests.
Figure 3An example of the wavelet transforms (a) and time-averaged wavelet amplitudes (b) of the skin blood flow signal.
Demographic and physiological information of subjects.
| Variable | Value (mean ± SD) |
|---|---|
| Gender (male/female) | 5/8 |
| Age (years) | 23.00 ± 0.58 |
| BMI (kg/m2) | 20.61 ± 2.91 |
| SBP (mmHg) | 118.62 ± 9.50 |
| DBP (mmHg) | 68.54 ± 7.62 |
| Heart rate (bpm) | 74.77 ± 10.73 |
| Ankle-brachial index | 1.03 ± 0.07 |
BMI, body mass index; SBP, systolic blood pressure; DBP, diastolic blood pressure.
Figure 4Increment of SBF during the recovery stage between the No Vibration test and the Vibration test. ∗indicates a significantly greater increment of SBF for the No Vibration test compared to the Vibration test in the corresponding period. p < 0.05.
Figure 5Percentage change in foot SBF between the baseline and recovery stages between the No Vibration test and the Vibration test. ∗indicates a significantly greater percentage change in SBF for the No Vibration test compared to the Vibration test. p < 0.05.
Figure 6Normalized wavelet amplitudes of foot SBF oscillations during the recovery stage in the No Vibration test and the Vibration test. ∗indicates a significantly higher normalized wavelet amplitude for the No Vibration test compared to the Vibration test. p < 0.05 and p < 0.01.