Evaluation of oversizing in association with conduction disorder after implantation of a rapid deployment valve.

Daijiro Hori1, Takahiro Yamamoto2, Sho Kusadokoro2, Tomonari Fujimori3, Makiko Naka Mieno2, Naoyuki Kimura2, Atsushi Yamaguchi2.   

Abstract

Rapid deployment valve has expanded surgical indication for high-risk patients with aortic stenosis despite its accommodated risk for conduction disorder (CD). The purpose of this study was to evaluate the degree of oversizing in association with postoperative CD. During June 2019 to September 2021, 25 patients underwent aortic valve replacement with Edwards INTUITY. Device size selection was evaluated intraoperatively using provided sizers. Oversizing was evaluated retrospectively by measuring the difference of the dimension of the annulus and left ventricular outflow tract (LVOT) compared to the dimensions of the device used by preoperative-computed tomography. Although there was no incidence of pacemaker implantation, seven patients (28.0%) experienced CD after surgery. There was no difference in device area and annulus area (CD: - 37 ± 22.7 mm2 vs. no CD: - 56 ± 63.6 mm2, p = 0.47), and device circumference and annulus circumference (CD: - 4.4 ± 2.77 mm vs. no CD: - 6.9 ± 5.60 mm, p = 0.26) in patients with and without CD. However, there was a significant difference in area of the device skirt and sub-annular area at the LVOT (CD: 114 ± 28.4 mm2 vs. no CD: - 8 ± 80.0 mm2, p < 0.001), and circumference of device skirt and the LVOT (CD: 3.9 ± 2.08 mm vs. no CD: - 4.6 ± 5.24 mm, p < 0.001) between the two groups. Receiver operating characteristic curve analysis showed that an area difference of 77.7 mm2 and circumference difference of 0.91 mm at LVOT were associated with postoperative CD with specificities of 0.83, 0.78 and sensitivity of 1.0, 1.0, respectively. Preoperative measurement of the LVOT may be useful in evaluating the risk of postoperative CD in patients receiving rapid deployment valve.
© 2021. The Japanese Society for Artificial Organs.

Entities:  

Keywords:  Conduction disorder; Intuity; Oversizing; Pacemaker; Rapid deployment valve

Mesh:

Year:  2021        PMID: 34727259     DOI: 10.1007/s10047-021-01301-4

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.385


  2 in total

1.  Hemodynamic Performance of Sutureless vs. Conventional Bioprostheses for Aortic Valve Replacement: The 1-Year Core-Lab Results of the Randomized PERSIST-AVR Trial.

Authors:  Theodor Fischlein; Elena Caporali; Federico M Asch; Ferdinand Vogt; Francesco Pollari; Thierry Folliguet; Utz Kappert; Bart Meuris; Malakh L Shrestha; Eric E Roselli; Nikolaos Bonaros; Olivier Fabre; Pierre Corbi; Giovanni Troise; Martin Andreas; Frederic Pinaud; Steffen Pfeiffer; Sami Kueri; Erwin Tan; Pierre Voisine; Evaldas Girdauskas; Filip Rega; Julio García-Puente; Laurent De Kerchove; Roberto Lorusso
Journal:  Front Cardiovasc Med       Date:  2022-02-18

2.  The Aortic Annulus Stabilization Technique Prevents Paravalvular Leaks after Rapid Deployment Aortic Valve Implantation.

Authors:  Elena Caporali; Roberto Lorusso; Tiziano Torre; Francesca Toto; Alberto Pozzoli; Giovanni Pedrazzini; Stefanos Demertzis; Enrico Ferrari
Journal:  J Clin Med       Date:  2021-12-10       Impact factor: 4.241

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.