Literature DB >> 34718497

Ascending aortic aneurysm haemodynamics are associated with aortic wall biomechanical properties.

Davis McClarty1, Maral Ouzounian2, Mingyi Tang1, Daniella Eliathamby3, David Romero1, Elsie Nguyen4, Craig A Simmons1,3, Cristina Amon1,3, Jennifer Chia-Ying Chung2.   

Abstract

OBJECTIVES: The effect of aortic haemodynamics on arterial wall properties in ascending thoracic aortic aneurysms (ATAAs) is not well understood. We aim to delineate the relationship between shear forces along the aortic wall and loco-regional biomechanical properties associated with the risk of aortic dissection.
METHODS: Five patients with ATAA underwent preoperative magnetic resonance angiogram and four-dimensional magnetic resonance imaging. From these scans, haemodynamic models were constructed to estimate maximum wall shear stress (WSS), maximum time-averaged WSS, average oscillating shear index and average relative residence time. Fourteen resected aortic samples from these patients underwent bi-axial tensile testing to determine energy loss (ΔUL) and elastic modulus (E10) in the longitudinal (ΔULlong, E10long) and circumferential (ΔULcirc, E10circ) directions and the anisotropic index (AI) for each parameter. Nine resected aortic samples underwent peel testing to determine the delamination strength (Sd). Haemodynamic indices were then correlated to the biomechanical properties.
RESULTS: A positive correlation was found between maximum WSS and ΔULlong rs=0.75, P = 0.002 and AIΔUL (rs=0.68, P=0.01). Increasing maximum time-averaged WSS was found to be associated with increasing ΔULlong (rs=0.73, P = 0.003) and AIΔUL (rs=0.62, P=0.02). Average oscillating shear index positively correlated with Sd (rs=0.73,P=0.04). No significant relationship was found between any haemodynamic index and E10, or between relative residence time and any biomechanical property.
CONCLUSIONS: Shear forces at the wall of ATAAs are associated with local degradation of arterial wall viscoelastic hysteresis (ΔUL) and delamination strength, a surrogate for aortic dissection. Haemodynamic indices may provide insights into aortic wall integrity, ultimately leading to novel metrics for assessing risks associated with ATAAs.
© The Author(s) 2021. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Aortic biomechanics; Ascending aortic aneurysm; Computational fluid dynamics; Magnetic resonance imaging

Mesh:

Year:  2022        PMID: 34718497     DOI: 10.1093/ejcts/ezab471

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  1 in total

1.  Elastin integrity in bicuspid valve-associated aortopathy is associated with altered biomechanical properties and influenced by age.

Authors:  Miriam Nightingale; David G Guzzardi; Alex J Barker; S Chris Malaisrie; Patrick M McCarthy; Michael Markl; Elena S Di Martino; Paul W M Fedak
Journal:  Ann Cardiothorac Surg       Date:  2022-07
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.