Eren Timurtaş1, Ender Ersin Avcı1, Kedar Mate2, Neslihan Karabacak1, Mine Gülden Polat1, İlkşan Demirbüken1.
Abstract
BACKGROUND: Using mobile application for postural assessments has been drawing a rising interest due to widespread use of smartphones. Although there are some mobile applications in use, validated mobile tools for accurate postural assessment are still warranted. AIMS: This study aimed to develop Fizyoprint mobile application tool to assess standing posture and investigate the validity and reliability of the application in young adults.Entities:
Keywords: Assessment; Mobile applications; Posture; Reliability; Validity
Mesh:
Year: 2021 PMID: 34716535 PMCID: PMC8556145 DOI: 10.1007/s11845-021-02827-5
Source DB: PubMed Journal: Ir J Med Sci ISSN: 0021-1265 Impact factor: 2.089
Fig. 1Fizyoprint app screenshots and positions of digital markers
Intra- and inter-rater agreements with the Fizyoprint app
| Measurement variables (cranial to caudal) | Intra-rater | Inter-rater | |
|---|---|---|---|
| R1 | R2 | R1 to R2 | |
| ICC classification | ICC classification | ICC classification | |
| Shoulder | 0.95*-EXC | 0.59-NA | 0.85*-VG |
| Pelvis | 0.45-NA | 0.79*-A | 0.76*-A |
| Knee | 0.89*-VG | 0.79*-A | 0.85*-VG |
| Head | 0.81*-VG | 0.92*-EXC | 0.71*-A |
| Shoulder | 0.93*-EXC | 0.91*-EXC | 0.76*-A |
| Umbilicus | 0.66-NA | 0.74*-A | 0.58-NA |
| Pelvis | 0.51-NA | 0.76*-A | 0.57-NA |
| Left foot | 0.95*-EXC | 0.81*-VG | 0.79*-A |
| Right foot | 0.88*-VG | 0.89*-VG | 0.88*-VG |
| Shoulder | 0.84*-VG | 0.81*-VG | 0.84*-VG |
| Pelvis | 0.49-NA | 0.64-NA | 0.61-NA |
| Knee | 0.93*-EXC | 0.79*-A | 0.91*-EXC |
| C7 | 0.87*-VG | 0.89*-VG | 0.86*-VG |
| T5 | 0.76*-A | 0.69-NA | 0.61-NA |
| Pelvis (posterior) | 0.81*-VG | 0.81*-VG | 0.44-NA |
| Left foot | 0.61-NA | 0.53-NA | 0.62-NA |
| Right foot | 0.72*-A | 0.35-NA | 0.51-NA |
| Head to shoulder | 0.98*-EXC | 0.89*-VG | 0.97*-EXC |
| Shoulder to pelvis | 0.97*-EXC | 0.91*-EXC | 0.96*-EXC |
| Hip to knee | 0.91*-EXC | 0.97*-EXC | 0.91*-EXC |
| Knee to foot | 0.85*-VG | 0.89*-VG | 0.84*-VG |
| Pelvis | 0.83*-VG | 0.93*-EXC | 0.86*-VG |
| Head | 0.81*-VG | 0.94*-EXC | 0.49-NA |
| Shoulder | 0.79*-A | 0.85*-VG | 0.69-NA |
| Hip | 0.67-NA | 0.67-NA | 0.57-NA |
| Knee | 0.83*-VG | 0.96*-EXC | 0.52-NA |
*Acceptable variables
Spearman’s rank correlation between Fizyoprint app and BioTonix™ posture analysis system
| Measurement levels | Fizyoprint-BioTonix™ | Fizyoprint-BioTonix™ |
|---|---|---|
| r-Classification | r-Classification | |
| Shoulder | ||
| Pelvis | ||
| Knee | ||
| Head | ||
| Shoulder | ||
| Umbilicus | ||
| Pelvis | ||
| Left foot | 0.33-F | 0.09-P |
| Right foot | ||
| Shoulder | ||
| Pelvis | ||
| Knee | ||
| C7 | ||
| T5 | ||
| Pelvis (posterior) | ||
| Left foot | ||
| Right foot | ||
| Head to shoulder | ||
| Shoulder to pelvis | ||
| Hip to knee | 0.35-F | 0.39-F |
| Knee to foot | ||
| Pelvis | ||
| Head | ||
| Shoulder | ||
| Hip | 0.32-F | 0.18-P |
| Knee | ||
*Acceptable variables