Literature DB >> 347057

Retention of endodontic dowels: effects of cement, dowel length, diameter, and design.

J P Standlee, A A Caputo, E C Hanson.   

Abstract

The retentive capacity of three preformed endodontic dowel designs was compared at two lengths and two diameters, with three different cements. The greatest single factor influencing retention of these devices was the design used. Of the types tested in this study, the most retentive were threaded, parallel-sided dowels screwed into tapped channels. Serrated, parallel-sided dowels cemented in matched cylindrical channels provided intermediate retention, and smooth-sided tapered posts were the least retentive. Another major factor in retention was the length of imbedment into dentin. An increase in dowel imbedment depth usually corresponded to increased retention. The effect of cement type was significant only with tapered dowels. Zinc phosphate cement was most retentive, carboxylate cement exhibited intermediate retention, and the epoxy cement was least retentive. For the other post designs, cement type had no significant effect on retentive capacity. Finally, variations in dowel diameter had no significant effect on retentive ability.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 347057     DOI: 10.1016/s0022-3913(78)80156-5

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  19 in total

1.  Effect of the ferrule on fracture resistance of teeth restored with prefabricated posts and composite cores.

Authors:  Annet Kutesa-Mutebi; Yusuf I Osman
Journal:  Afr Health Sci       Date:  2004-08       Impact factor: 0.927

2.  In vitro evaluation of the effect of post system and length on the fracture resistance of endodontically treated human anterior teeth.

Authors:  Sahil Jindal; Ritu Jindal; Sandeep Mahajan; Rohini Dua; Namita Jain; Sunila Sharma
Journal:  Clin Oral Investig       Date:  2012-01-14       Impact factor: 3.573

3.  A Comparative Evaluation of the Retention of Tooth Coloured and Stainless Steel Endodontic Posts: An In-vitro Study.

Authors:  Kiran Keswani; Rahul Maria; Rohit Punga
Journal:  J Clin Diagn Res       Date:  2014-04-15

4.  FEM analysis of the mandibular first premolar with different post diameters.

Authors:  Je-Kang Du; Wei-Ko Lin; Chau-Hsiang Wang; Huey-Er Lee; Hung-Yuan Li; Ju-Hui Wu
Journal:  Odontology       Date:  2011-04-14       Impact factor: 2.634

5.  The taper of cast post preparation measured using innovative image processing technique.

Authors:  Khaled Q Al Hamad; Faruq A Al-Omari; Ahmad S Al Hyiasat
Journal:  BMC Oral Health       Date:  2010-08-04       Impact factor: 2.757

6.  Does an intracanal composite anchorage replace posts?

Authors:  Gabriel Krastl; Andres Izquierdo; Leonard Büttel; Nicola U Zitzmann; Marc Schmitter; Roland Weiger
Journal:  Clin Oral Investig       Date:  2013-03-16       Impact factor: 3.573

7.  In vitro evaluation of ferrule effect and depth of post insertion on fracture resistance of fiber posts.

Authors:  R Schiavetti; G Sannino
Journal:  Comput Math Methods Med       Date:  2012-12-02       Impact factor: 2.238

8.  Comparative evaluation of the reinforcing effect of different post systems in the restoration of endodontically treated human anterior teeth at two different lengths of post space preparation- an in vitro study.

Authors:  Sahil Jindal; Ritu Jindal; Kanika Gupta; Sandeep Mahajan; Sunidhi Garg
Journal:  J Dent (Tehran)       Date:  2013-03-31

9.  Effect of eugenol-containing sealer and post diameter on the retention of fiber reinforced composite posts.

Authors:  Alireza Izadi; Mohadese Azarsina; Shahin Kasraei
Journal:  J Conserv Dent       Date:  2013-01

10.  Fracture resistance of teeth restored with cast post and core: An in vitro study.

Authors:  S Mankar; N S Mohan Kumar; J V Karunakaran; S Senthil Kumar
Journal:  J Pharm Bioallied Sci       Date:  2012-08
View more