Literature DB >> 34704637

In Vitro Validation of Regional Circumferential Strain Assessment in a Phantom Aortic Model Using Cine Displacement Encoding With Stimulated Echoes MRI.

John S Wilson1,2, Muhammad Islam3, John N Oshinski3,4.   

Abstract

BACKGROUND: A novel application of cine Displacement ENcoding with Stimulated Echoes Magnetic Resonance Imaging (DENSE MRI) has recently been described to assess regional heterogeneities in circumferential strain around the aortic wall in vivo; however, validation is first required for successful clinical translation.
PURPOSE: To validate the quantification of regional circumferential strain around the wall of an aortic phantom using DENSE MRI. STUDY TYPE: In vitro phantom study. POPULATION: Three polyvinyl alcohol aortic phantoms with eight axially oriented nitinol wires embedded evenly around the walls. FIELD STRENGTH/SEQUENCE: 3 T; gradient-echo aortic DENSE MRI with spiral cine readout, gradient-echo phase-contrast MRI (PCMR) with Cartesian cine readout. ASSESSMENT: Phantoms were connected to a pulsatile flow loop and peak DENSE-derived regional circumferential Green strains at 16 equally spaced sectors around the wall were assessed according to previously published algorithms. "True" regional circumferential strains were calculated by manually tracking displacements of the nitinol wires by two independent observers. Normalized circumferential strains (NCS) were calculated by dividing regional strains by the mean strain. Finally, DENSE-derived regional strain was corrected by multiplying regional DENSE NCS by the mean strain calculated from the diameter change on the PCMR. STATISTICAL TESTS: One-sample t-test, Paired-sample t-test, and analysis of variance with Bonferroni correction, coefficient of variation (CoV), Bland-Altman analysis; P < 0.05 was considered statistically significant.
RESULTS: Aortic DENSE MRI significantly overestimated circumferential strain compared to the wire-tracking method (mean difference and SD 0.030 ± 0.014, CoV 0.31). However, NCS demonstrated good agreement between DENSE and wire-tracking data (mean difference 0.000 ± 0.172, CoV 0.15). After correcting the DENSE-derived regional strain, the mean difference in regional circumferential strain between DENSE and wire-tracking was significantly reduced to 0.006 ± 0.008, and the CoV was reduced to 0.18. DATA
CONCLUSION: For aortic phantoms with mild spatial heterogeneity in circumferential strain, the previously published aortic DENSE MRI technique successfully assessed the regional NCS distribution but overestimated the mean strain. This overestimation is correctable by computing a more accurate mean circumferential strain using a separate cine scan. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.
© 2021 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  DENSE MRI; aorta; circumferential strain; validation; vascular phantom

Mesh:

Year:  2021        PMID: 34704637      PMCID: PMC9043029          DOI: 10.1002/jmri.27972

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   5.119


  28 in total

1.  Steady flow and wall compression in stenotic arteries: a three-dimensional thick-wall model with fluid-wall interactions.

Authors:  D Tang; C Yang; S Kobayashi; D N Ku
Journal:  J Biomech Eng       Date:  2001-12       Impact factor: 2.097

2.  DENSE: displacement encoding with stimulated echoes in cardiac functional MRI.

Authors:  A H Aletras; S Ding; R S Balaban; H Wen
Journal:  J Magn Reson       Date:  1999-03       Impact factor: 2.229

3.  Measuring Diffusion in the Presence of Material Strain

Authors: 
Journal:  J Magn Reson B       Date:  1996-09

4.  Tracking myocardial motion from cine DENSE images using spatiotemporal phase unwrapping and temporal fitting.

Authors:  B S Spottiswoode; X Zhong; A T Hess; C M Kramer; E M Meintjes; B M Mayosi; Frederick H Epstein
Journal:  IEEE Trans Med Imaging       Date:  2007-01       Impact factor: 10.048

5.  Impact of Thoracic Endovascular Aortic Repair on Pulsatile Circumferential and Longitudinal Strain in Patients With Aneurysm.

Authors:  Foeke J H Nauta; Guido H W van Bogerijen; Chiara Trentin; Michele Conti; Ferdinando Auricchio; Frans L Moll; Joost A van Herwaarden; Santi Trimarchi
Journal:  J Endovasc Ther       Date:  2017-01-19       Impact factor: 3.487

6.  A validation of two-dimensional in vivo regional strain computed from displacement encoding with stimulated echoes (DENSE), in reference to tagged magnetic resonance imaging and studies in repeatability.

Authors:  Julia Kar; Andrew K Knutsen; Brian P Cupps; Michael K Pasque
Journal:  Ann Biomed Eng       Date:  2013-10-23       Impact factor: 3.934

7.  Including surrounding tissue improves ultrasound-based 3D mechanical characterization of abdominal aortic aneurysms.

Authors:  Niels J Petterson; Emiel M J van Disseldorp; Marc R H M van Sambeek; Frans N van de Vosse; Richard G P Lopata
Journal:  J Biomech       Date:  2019-01-19       Impact factor: 2.712

8.  Using MRI to assess aortic wall thickness in the multiethnic study of atherosclerosis: distribution by race, sex, and age.

Authors:  Arthur E Li; Ihab Kamel; Felice Rando; Melissa Anderson; Basak Kumbasar; João A C Lima; David A Bluemke
Journal:  AJR Am J Roentgenol       Date:  2004-03       Impact factor: 3.959

9.  Feasibility of asymmetric stretch assessment in the ascending aortic wall with DENSE cardiovascular magnetic resonance.

Authors:  Henrik Haraldsson; Michael Hope; Gabriel Acevedo-Bolton; Elaine Tseng; Xiaodong Zhong; Frederick H Epstein; Liang Ge; David Saloner
Journal:  J Cardiovasc Magn Reson       Date:  2014-01-09       Impact factor: 5.364

10.  Assessment of the regional distribution of normalized circumferential strain in the thoracic and abdominal aorta using DENSE cardiovascular magnetic resonance.

Authors:  John S Wilson; W Robert Taylor; John Oshinski
Journal:  J Cardiovasc Magn Reson       Date:  2019-09-16       Impact factor: 5.364

View more
  1 in total

1.  Quantification of the heterogeneous effect of static and dynamic perivascular structures on patient-specific local aortic wall mechanics using inverse finite element modeling and DENSE MRI.

Authors:  Johane H Bracamonte; John S Wilson; Joao S Soares
Journal:  J Biomech       Date:  2022-05-05       Impact factor: 2.789

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.