Literature DB >> 3469380

Evaluation of proximal contacts with shim stock.

P A Boice, S M Niles, L M Dubois.   

Abstract

A total of 969 proximal contacts in forty volunteer subjects was examined for proximal contact integrity with shim stock. It passed uninhibited through 88% of the contacts. Neither sex nor age affected the evaluation; however, shim stock was more likely to pass through contacts with enamel surfaces than those which were restored.

Mesh:

Year:  1987        PMID: 3469380     DOI: 10.1111/j.1365-2842.1987.tb00697.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837