TiO2/MXene-PVA/GO hydrogel-based electrochemical sensor for neurological disorder screening via urinary norepinephrine detection.

Siraprapa Boobphahom1, Tatiya Siripongpreda2, DongDong Zhang2, Jiaqian Qin1,3, Pranee Rattanawaleedirojn1,3, Nadnudda Rodthongkum4,5.   

Abstract

A hydrogel based on titanium dioxide/MXene with polyvinyl alcohol/graphene oxide (TiO2/MXene-PVA/GO) composite was successfully formulated and applied to modify a screen-printed carbon electrode (SPCE) for urinary norepinephrine (NE) detection. The characterization confirmed that a nanocomposite hydrogel structure of TiO2/MXene-PVA/GO was formed. The as-prepared hydrogel substantially enhanced the sensor performances due to electrocatalytic activity of TiO2, high conductivity of MXene, and auto-sample preconcentration via PVA/GO hydrogel. The electrochemical behavior of NE was investigated by cyclic voltammetry and amperometry. Under optimized conditions, the TiO2/MXene-PVA/GO hydrogel/SPCE response due to the oxidation of NE at +0.4 V (vs. Ag|AgCl) is proportional to the concentration of NE over 0.01 to 1.00 μM (R2 = 0.9968) and 1.00 to 60.0 μM (R2 = 0.9936) ranges with a detection limit (3σ) of 6 nM without interferent effect from common interferences in urine. Furthermore, this sensor was employed for urinary NE determination and validated by high performance liquid chromatography (HPLC) with a UV detector at 280 nm; the average recovery was found to be 97.6 to 102%, with a relative standard deviation (RSD) less than 4.9%. This device was sensitive enough to evaluate an early stage of neurological disorder via detecting clinically relevant NE level. Eventually, it was integrated with pantyliners which could be a potential wearable sensor in the near future.
© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Austria, part of Springer Nature.

Entities:  

Keywords:  Electrochemical sensor; Neurological disorder; TiO2/MXene-PVA/GO hydrogel; Urinary norepinephrine; Voltammetry

Mesh:

Substances:

Year:  2021        PMID: 34668069     DOI: 10.1007/s00604-021-04945-4

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  1 in total

1.  Highly Sensitive and Stable Humidity Sensor Based on the Bi-Layered PVA/Graphene Flower Composite Film.

Authors:  Sheik Abdur Rahman; Shenawar Ali Khan; Muhammad Muqeet Rehman; Woo-Young Kim
Journal:  Nanomaterials (Basel)       Date:  2022-03-21       Impact factor: 5.076

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.