| Literature DB >> 34667343 |
M S Varnitha1, Ajay Kumar1, Priyanka Gupta1, Vikas Yadav1, Ankit Agarwal1, Anshuman Darbari2.
Abstract
BACKGROUND: Three different types of cannulation method for radial artery are Direct technique, Seldinger technique, and modified Seldinger technique (Dart). Their comparative efficacy has been studied using palpatory method but not with ultrasound guidance. AIMS: We compared the efficacy of ultrasound-guided Direct and ultrasound-guided Dart technique of arterial cannulation. SETTINGS ANDEntities:
Keywords: Dart technique; Direct technique; first-pass access; prospective studies; radial artery cannulation; ultrasound-guided arterial cannulation
Year: 2021 PMID: 34667343 PMCID: PMC8462409 DOI: 10.4103/aer.aer_61_21
Source DB: PubMed Journal: Anesth Essays Res ISSN: 2229-7685
Figure 1(a) Direct cannula needle with catheter; (b) Dart Cannula needle with integrated guidewire; (c) Direct Catheter being pushed over Cannula stylet in ultrasound guidance; (d) guidewire passing into the radial artery (hollow arrow) under ultrasound guidance
Figure 2Consort flow-diagram
Demographic variables
| Parameters | Method |
| |
|---|---|---|---|
|
| |||
| Direct ( | Dart ( | ||
| Age (years) | 41.9±12.1 | 42.0±15.6 | 0.746a |
| Gender (male/female) | 44/36 | 49/31 | 0.423b |
| BMI (kg/m2) | 23.0±3.6 | 23.2±6.9 | 0.428a |
| ASA grade l/ll/lll | 30/17/33 | 31/28/21 | 0.068b |
| Surgery (cardiac/noncardiac) | 24/56 | 29/51 | 0.401b |
| Heart rate (b/min) | 85.1±15.0 | 87.1±16.0 | 0.360a |
| Systolic BP (mmHg) | 127.6±19.6 | 124.8±26.7 | 0.319a |
| Diastolic BP (mmHg) | 77.8±14.9 | 74.7±13.4 | 0.061a |
| MAP (mmHg) | 94.4±15.0 | 91.4±16.0 | 0.083a |
| Radial artery lumen (mm) | 2.19±0.47 | 2.11±0.48 | 0.310c |
| Pulse (normal/feeble) | 71/9 | 68/12 | 0.482b |
aWilcoxon test, bChi-squared test, ct-test. Direct=Direct technique, Dart=Modified seldinger technique with integrated guide wire, BMI=Body mass index, ASA=American society of anaesthesiologist, BP=Blood pressure, MAP=Mean arterial pressure
Primary and secondary objectives
| Parameters | Method | ||
|---|---|---|---|
|
| |||
| Direct ( | Dart ( |
| |
| Successful cannulation (%) | 46 (57.5) | 44 (55.0) | 0.750b |
| Time to cannulation (s) | 208.4±126.0 | 232.1±143.5 | 0.426a |
| Number of attempts 1/2/≥3 | 57/17/6 | 45/28/7 | 0.124b |
| Number of needle redirections≤1/2/3/≥4 | 22/25/21/12 | 23/16/19/22 | 0.169b |
| Posterior wall puncture (present) | 20 (25.0) | 31 (38.8) | 0.062b |
| Hematoma (present)*** | 18 (22.5) | 8 (10.0) | 0.032b |
***Significant at P<0.05, aWilcoxon test, bChi-squared test. Values are presented as n (%), Direct=Direct technique, Dart=Modified seldinger technique with integrated guide wire
Association between successful cannulation and parameters
| Parameters | Successful cannulation within 5 (min) |
| |
|---|---|---|---|
|
| |||
| Present ( | Absent ( | ||
| Type of surgery | |||
| Cardiac | 31 (34.4) | 22 (31.4) | 0.688a |
| Noncardiac | 59 (65.6) | 48 (68.6) | |
| Pulse*** | |||
| Normal | 83 (92.2) | 56 (80.0) | 0.023a |
| Feeble | 7 (7.8) | 14 (20.0) | |
| Number of attempts 1/2/≥3*** | 81/9/0 | 21/36/13 | <0.001a |
| Number of needle redirections≤1/2/3/≥4*** | 45/24/17/4 | 0/17/23/30 | <0.001a |
| Posterior wall puncture*** | 9 (10.0) | 42 (60.0) | <0.001a |
| Hematoma (present)*** | 0 | 26 (37.1) | <0.001a |
| Radial artery lumen (mm)*** | 2.25±0.46 | 2.02±0.47 | 0.002b |
***Significant at P<0.05, aChi square test, bt-test. Values are presented as n (%)