Literature DB >> 34659473

Distal biceps tendon repair via new knotless endobutton fixation: A biomechanical study.

Victor Rutka1, Florent Weppe1, Sonia Duprey2, Laure-Lise Gras2.   

Abstract

BACKGROUND: Distal biceps tendon repair using endobutton fixation has shown the best biomechanical results in terms of pullout strength. Here, we compared Sethi's enhanced tension adjustable endobutton technique known as the "tension slide technique" to a new knotless endobutton fixation technique without a post-fixation screw. Our new approach is as effective as the tension slide technique in terms of pullout strength and gapping after early mobilization.
METHODS: A biomechanical cadaveric study with 16 paired arms was performed. With the radius held in place, the distal biceps tendon was loaded at 100 N for 500 cycles and the load was then increased until failure. Gapping after loading cycles and maximum load to failure were recorded and compared.
RESULTS: Median bone-tendon gapping was 5.77 mm (interquartile range (IQR) 4.84-9.11) for tension slide technique and 4.72 mm (IQR 1.77-6.16) for the knotless fixation (p = 0.047). Median load to failure was 257.87 N (IQR 222.07-325.35) in the tension slide technique group and 407.78 N (IQR 358.54-485.20) in the knotless group (p = 0.047). DISCUSSION: The knotless endobutton provides better pullout strength and elongation results compared to the tension slide technique without the use of an interference screw, allowing early mobilization in order to faster return to daily living activities.Level of evidence: Basic science study.
© 2019 The British Elbow & Shoulder Society.

Entities:  

Keywords:  biomechanics; cortical button; distal biceps repair; elbow; tendon injuries; tensile strength

Year:  2019        PMID: 34659473      PMCID: PMC8512990          DOI: 10.1177/1758573219864303

Source DB:  PubMed          Journal:  Shoulder Elbow        ISSN: 1758-5732


  31 in total

Review 1.  Fixation of Soft Tissue to Bone: Techniques and Fundamentals.

Authors:  Brian J Cole; Eli T Sayegh; Adam B Yanke; Peter N Chalmers; Rachel M Frank
Journal:  J Am Acad Orthop Surg       Date:  2016-02       Impact factor: 3.020

2.  A biomechanical comparison of EndoButton versus suture anchor repair of distal biceps tendon injuries.

Authors:  Jeffrey T Spang; Paul S Weinhold; Spero G Karas
Journal:  J Shoulder Elbow Surg       Date:  2006 Jul-Aug       Impact factor: 3.019

3.  Reconstruction of the distal ulna: instability, impaction, impingement, and arthrosis.

Authors:  Jeffrey A Greenberg
Journal:  J Hand Surg Am       Date:  2009-02       Impact factor: 2.230

4.  Biomechanical evaluation of distal biceps reconstruction with cortical button and interference screw fixation.

Authors:  Paul Sethi; Elifho Obopilwe; Lina Rincon; Seth Miller; Augustus Mazzocca
Journal:  J Shoulder Elbow Surg       Date:  2010-01       Impact factor: 3.019

5.  Proximity of the posterior interosseous nerve during cortical button guidewire placement for distal biceps tendon reattachment.

Authors:  Nicolas Thumm; Douglas Hutchinson; Chong Zhang; Sebastian Drago; Andrew R Tyser
Journal:  J Hand Surg Am       Date:  2014-12-13       Impact factor: 2.230

Review 6.  Surgical Management of Acute Distal Biceps Tendon Ruptures.

Authors:  David D Savin; Jonathan Watson; Ari R Youderian; Simon Lee; Jon E Hammarstedt; Mark R Hutchinson; Benjamin A Goldberg
Journal:  J Bone Joint Surg Am       Date:  2017-05-03       Impact factor: 5.284

7.  Rupture of the distal tendon of the biceps brachii. Operative versus non-operative treatment.

Authors:  B E Baker; D Bierwagen
Journal:  J Bone Joint Surg Am       Date:  1985-03       Impact factor: 5.284

8.  Surgical Treatment of Distal Biceps Tendon Ruptures: An Analysis of Complications in 784 Surgical Repairs.

Authors:  Taylor R Dunphy; Justin Hudson; Michael Batech; Daniel C Acevedo; Raffy Mirzayan
Journal:  Am J Sports Med       Date:  2017-08-24       Impact factor: 6.202

9.  EndoButton-assisted repair of distal biceps tendon ruptures.

Authors:  Jeffrey A Greenberg; John J Fernandez; Tongyu Wang; Charles Turner
Journal:  J Shoulder Elbow Surg       Date:  2003 Sep-Oct       Impact factor: 3.019

10.  Failure strengths in distal biceps tendon repair.

Authors:  Mark Kettler; Josef Lunger; Volker Kuhn; Wulf Mutschler; Markus J Tingart
Journal:  Am J Sports Med       Date:  2007-03-29       Impact factor: 6.202

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.