Rohollah Ghahraman Asl1, Rezvan Sabbaghi2, Hadi Taleshi Ahangari2, Payman Hejazi2, Majid Foroutan3.
Abstract
INTRODUCTION: This study aimed to predict the dose absorbed by normal organs with neuroendocrine tumors for 131I using single photon emission computed tomography/computed tomography (SPECT/CT) images and Geant4 application for tomographic emission (GATE) simulation.Entities:
Keywords: Geant4 application for tomographic emission; I-131; S-value; image base internal dosimetry; patient-specific dosimetry; single photon emission computed tomography/computed tomography
Year: 2021 PMID: 34658551 PMCID: PMC8481846 DOI: 10.4103/ijnm.ijnm_6_21
Source DB: PubMed Journal: Indian J Nucl Med ISSN: 0974-0244
Demographic information of 4 patients with information on medical internal radiation dose phantom and organ selective mass
| Patients and phantoms characteristics | Organ masses | |||||||
|---|---|---|---|---|---|---|---|---|
|
|
| |||||||
| Sex | Age (years) | Weight (kg) | Height (cm) | Kidneys | Liver | Spleen | Thyroid | |
| Patient 1 | Male | 27 | 61 | 164 | 220.3 | 1315.4 | 395.4 | 18 |
| Patient 2 | Male | 42 | 84 | 179 | 308.6 | 2239.9 | 306.7 | 25 |
| Patient 3 | Female | 64 | 73 | 155 | 266.1 | 1245.1 | 214.2 | 20 |
| Patient 4 | Female | 63 | 53 | 158 | 280.4 | 1284.0 | 357.8 | 16 |
| MIRD adult phantom | Male | - | 73.7 | 167 | 299.0 | 1910.0 | 183.0 | 20 |
| MIRD adult phantom | Female | - | 56.8 | 157 | 255.0 | 1400.0 | 150.0 | 17 |
MIRD: Medical internal radiation dose
Figure 1Decay time activity data for some of the normal organs of the four patients
Residence times of the selected source organs in this study
| Residence times (h) | ||||
|---|---|---|---|---|
|
| ||||
| Organ | Patient 1 | Patient 2 | Patient 3 | Patient 4 |
| Kidneys | 0.28 | 0.2 | 0.38 | 0.39 |
| Liver | 0.79 | 0.5 | 1.26 | 1.81 |
| Spleen | 1.81 | 0.3 | 0.6 | 1.85 |
| Tumor | - | 0.06 | 0.22 | 0.05 |
| Thyroid | 0.013 | 0.019 | 0.017 | 0.03 |
Summary of percentage differences between 131I patient-specific S values (mGy/MBq.s) calculated by GATE and MIRD methods for 4 patients
| Percentage RD | Patient 1 | Patient 2 | Patient 3 | Patient 4 | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||
| K | S | L | T | K | S | L | T | K | S | L | T | K | S | L | T | |
| Kidneys | -6.8 | 9.7 | 47.6 | 78.6 | -4.2 | -37.8 | -10.8 | -21.7 | -5.5 | -7 | -86 | 16 | 2.4 | -19.4 | -39.3 | -32.8 |
| Spleen | 10 | -1 | 64.5 | -31.9 | -37.3 | -1 | 46.3 | -21.9 | -6.2 | 3.4 | -1.9 | 25.6 | -18.5 | 0.5 | 60.9 | 4.7 |
| Liver | 18.7 | 66.4 | -5.8 | 30.4 | -13 | 45.8 | -1.4 | 28.9 | -39.3 | -2.2 | -4.2 | -23.8 | -39.3 | 59.6 | -3.5 | -2 |
| Thyroid | 61.4 | -28.7 | 30.4 | 1.3 | -43.8 | -25.2 | -30.4 | 0.6 | 15.8 | 27.9 | -23.2 | 0.5 | -29 | 5.2 | -2.2 | -1.6 |
K: Kidney, L: Liver, S: Spleen, T: Thyroid, RD: Relative difference
Organ dose calculatedfor131I by GATE and medical internal radiation dose methods
| Total dose (self-dose+cross-dose) (mGy/MBq) | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| ||||||||
| Kidneys | Liver | Thyroid | Spleen | |||||
|
|
|
|
| |||||
| GATE | MIRD | GATE | MIRD | GATE | MIRD | GATE | MIRD | |
| Patient 1 | 1.39E-1 | 1.80E-1 | 8.54E-2 | 9.03E-2 | 7.50E-2 | 7.36E-2 | 5.76E-1 | 5.83E-1 |
| Ratio DGATE/DMIRD | 0.77 | 0.94 | 1.02 | 0.99 | ||||
| Patient 2 | 8.01E-2 | 8.48E-2 | 3.50E-2 | 3.33E-2 | 1.14E-1 | 1.07E-2 | 1.30E-1 | 1.25E-1 |
| Ratio DGATE/DMIRD | 0.94 | 1.05 | 1.06 | 1.04 | ||||
| Patient 3 | 1.82E-1 | 1.88E-1 | 1.41E-1 | 1.46E-1 | 1.21E-1 | 1.17E-1 | 3.45E-1 | 3.56E-1 |
| Ratio DGATE/DMIRD | 0.97 | 0.97 | 1.03 | 0.97 | ||||
| Patient 4 | 1.88E-1 | 1.95E-1 | 1.97E-1 | 2.04E-1 | 2.03E-1 | 2.06E-1 | 6.64E-1 | 6.53E-1 |
| Ratio DGATE/DMIRD | 0.96 | 0.96 | 0.98 | 1.02 | ||||
| Total dose (GATE) | 1.47E-1 | 1.15E-1 | 1.28E-1 | 4.26E-1 | ||||
MIRD: Medical internal radiation dose, GATE: Geant4 application for tomographic emission
Figure 2Ratio between Geant4 application for tomographic emission and MIRDOSE absorbed doses for the four patients. No tumor was visible in a single single photon emission computed tomography field of view for patient 1
Tumor mass, tumor doses for patients with pathologic uptake
| Patient 1 | Patient 2 | Patient 3 | Patient 4 | |||||
|---|---|---|---|---|---|---|---|---|
| Tumor numbered | - | 2 | 1 | 1 | ||||
| Tumor mass (g) | - | 47.54 | 24.45 | 18.08 | ||||
|
| ||||||||
|
|
|
|
|
|
|
|
| |
|
| ||||||||
| Self-dose (GATE) | - | - | 6.36E-01 | 5.72E-01 | 1.01E+00 | 1.02E+00 | 2.89E-01 | 2.96E-01 |
| Total dose | - | - | 6.42E-01 | 5.67E-01 | 1.014E+00 | 1.02E+00 | 3.53E-01 | 2.96E-01 |
MIRD: Medical internal radiation dose, GATE: Geant4 application for tomographic emission
Figure 3The percent contributions of self- and cross-doses