Hybrid Left Heart Bypass Circuit for Repair of the Descending Aorta in an 8-kg Williams Syndrome Patient.

Gregory S Matte1, William L Regan1, Kevin R Connor1, Dima G Daaboul1, David M Hoganson1, Luis G Quinonez1.   

Abstract

A 1-year old male patient with Williams syndrome and multiple prior interventions presented for surgical repair of his descending aorta (DA) through a left thoracotomy. Concerns for significant bleeding and spinal cord protection led the care team to consider a left heart bypass (LHB) circuit with options for pump sucker use, heat exchange capacity, and the possibility of converting to traditional cardiopulmonary bypass (CPB). A traditional CPB circuit with a roller-head arterial pump was assembled with a bypass line around the cardiotomy venous reservoir (CVR). Excluding the CVR with this line allowed for a closed LHB circuit. A second pump head was integrated to both recirculate the CVR volume and to serve as a means for controlled volume administration to the closed LHB circuit. Pump sucker return directed to the CVR could easily be transfused back to the patient. The patient was placed on the hybrid LHB circuit and cooled to 32°C. DA clamps were placed. Upper body dynamic blood pressure was managed for a target mean of 50 mmHg, the left atrial pressure (LAP) was maintained in the 5-7 mmHg range, and the nonpulsatile lower body blood pressure was targeted at 40-50 mmHg. Cerebral near-infrared spectroscopy (NIRS) helped guide volume and pressure management. The surgeons placed two long-segment patches on the DA, moving clamps as needed. The patient was rewarmed and separated from the hybrid LHB circuit after 82 minutes. Closed circuit LHB can be provided with a roller-head hybrid circuit incorporating an oxygenator for gas exchange, central cooling and warming, and arterial line filtration along with a CVR for pump sucker use and controlled transfusion to the patient. © Copyright 2021 AMSECT.

Entities:  

Keywords:  METEOR circuit; Williams syndrome; hybrid left heart bypass circuit; left heart bypass; pediatric; pump suckers

Mesh:

Year:  2021        PMID: 34658410      PMCID: PMC8499637          DOI: 10.1182/ject-2100022

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  16 in total

1.  Use of a multi-modality life support system.

Authors:  Nicholas Brindisi; Alfred Stammers; Cody Trowbridge; Myra Klayman; James Pezzuto; Molly Marko
Journal:  J Extra Corpor Technol       Date:  2008-12

2.  International pediatric perfusion practice: 2011 survey results.

Authors:  Brian Harvey; Kenneth G Shann; David Fitzgerald; Brian Mejak; Donald S Likosky; Luc Puis; Robert A Baker; Robert C Groom
Journal:  J Extra Corpor Technol       Date:  2012-12

3.  Elective hypothermic cardiopulmonary bypass and circulatory arrest for spinal cord protection during operations on the thoracoabdominal aorta.

Authors:  N T Kouchoukos; T H Wareing; H Izumoto; W Klausing; N Abboud
Journal:  J Thorac Cardiovasc Surg       Date:  1990-04       Impact factor: 5.209

4.  A Modified EXIT-to-ECMO with Optional Reservoir Circuit for Use during an EXIT Procedure Requiring Thoracic Surgery.

Authors:  Gregory S Matte; Kevin R Connor; Nathalia A Toutenel; Danielle Gottlieb; Francis Fynn-Thompson
Journal:  J Extra Corpor Technol       Date:  2016-03

5.  Hypothermic cardiopulmonary bypass for spinal cord protection: rationale and clinical results.

Authors:  N T Kouchoukos; C K Rokkas
Journal:  Ann Thorac Surg       Date:  1999-06       Impact factor: 4.330

Review 6.  Survey of mechanical assistance of the circulation and the present status of left-heart bypass.

Authors:  R J Baird; C J Labrosse; T Z Lajos
Journal:  Can Med Assoc J       Date:  1966-09-24       Impact factor: 8.262

7.  Surface-bound heparin fails to reduce thrombin formation during clinical cardiopulmonary bypass.

Authors:  R C Gorman; N Ziats; A K Rao; N Gikakis; L Sun; M M Khan; N Stenach; S Sapatnekar; V Chouhan; J H Gorman; S Niewiarowski; R W Colman; J M Anderson; L H Edmunds
Journal:  J Thorac Cardiovasc Surg       Date:  1996-01       Impact factor: 5.209

8.  The BICIRCUIT system: innovative perfusional options for surgical treatment of the thoracic aorta.

Authors:  Gianluigi Bisleri; Giancarlo Tisi; Alberto Negri; Jacopo Manfredi; Enrico Carone; Jeffrey A Morgan; Claudio Muneretto
Journal:  Ann Thorac Surg       Date:  2005-02       Impact factor: 4.330

9.  Arterial Limb Microemboli during Cardiopulmonary Bypass: Observations from a Congenital Cardiac Surgery Practice.

Authors:  Gregory S Matte; Kevin R Connor; Hua Liu; James A DiNardo; David Faraoni; Frank Pigula
Journal:  J Extra Corpor Technol       Date:  2016-03

Review 10.  The use of left heart bypass in the repair of thoracoabdominal aortic aneurysms: current techniques and results.

Authors:  Joseph S Coselli
Journal:  Semin Thorac Cardiovasc Surg       Date:  2003-10
View more
  1 in total

1.  The application of modular multifunctional left heart bypass circuit system integrated with ultrafiltration in thoracoabdominal aortic aneurysm repair.

Authors:  Lingjin Huang; Xuliang Chen; Qinghua Hu; Fanyan Luo; Jiajia Hu; Lian Duan; E Wang; Zhi Ye; Chengliang Zhang
Journal:  Front Cardiovasc Med       Date:  2022-09-21
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.