Acoustic characterization of tissue-mimicking materials for ultrasound perfusion imaging research.

Peiran Chen1, Andreas M A O Pollet2, Anastasiia Panfilova3, Meiyi Zhou3, Simona Turco3, Jaap M J den Toonder2, Massimo Mischi3.   

Abstract

Materials with well-characterized acoustic properties are of great interest for the development of tissue-mimicking phantoms with designed (micro)vasculature networks. These represent a useful means for controlled in-vitro experiments to validate perfusion imaging methods such as Doppler and contrast-enhanced ultrasound (CEUS) imaging. In this work, acoustic properties of seven tissue-mimicking phantom materials at different concentrations of their compounds and five phantom case materials are characterized and compared at room temperature. The goal of this research is to determine the most suitable phantom and case material for ultrasound perfusion imaging experiments. The measurements show a wide range in speed of sound varying from 1057 to 1616 m/s, acoustic impedance varying from 1.09 to 1.71 × 106 kg/m2s, and attenuation coefficients varying from 0.1 to 22.18 dB/cm at frequencies varying from 1 MHz to 6 MHz for different phantom materials. The nonlinearity parameter B/A varies from 6.1 to 12.3 for most phantom materials. This work also reports the speed of sound, acoustic impedance and attenuation coefficient for case materials. According to our results, polyacrylamide (PAA) and polymethylpentene (TPX) are the optimal materials for phantoms and their cases, respectively. To demonstrate the performance of the optimal materials, we performed power Doppler ultrasound imaging of a perfusable phantom, and CEUS imaging of that phantom and a perfusion system. The obtained results can assist researchers in the selection of the most suited materials for in-vitro studies with ultrasound imaging.
Copyright © 2021 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  acoustic properties; case materials; perfusable phantoms; tissue-mimicking materials; ultrasound perfusion imaging

Mesh:

Year:  2021        PMID: 34654580     DOI: 10.1016/j.ultrasmedbio.2021.09.004

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  1 in total

1.  A Comparison of the Sensitivity of Contrast-Specific Imaging Modes on Clinical and Preclinical Ultrasound Scanners.

Authors:  Carmel M Moran; Charles Arthur; Emilio Quaia
Journal:  Tomography       Date:  2022-09-15
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.