Literature DB >> 34642797

Direct endoscopic placement of percutaneous endoscopic gastrostomies with jejunal extension tubes (PEG-J) using ultra-thin endoscopes - long-term outcomes from a U.S. tertiary referral center.

Yazan Hasan1, Asad Ali1, Amer El Sayed1, Avraham Levin1, Henning Gerke1, Hye Yeon Jhun1, Mohamad Mokadem1, Rami El Abiad1, Randhir Jesudoss1, Steven Polyak1, Nadav Sahar2.   

Abstract

INTRODUCTION: Several techniques for PEG-J tube placement have been described, commonly requiring fluoroscopic guidance and/or fixation of the jejunostomy tube (J-tube) into the small intestine. We describe a modified technique for placing jejunostomy tubes under direct visualization through a PEG with the use of ultra-thin endoscopes and steel guidewire.
METHODS: A retrospective study at a single tertiary academic center evaluating patients who underwent PEG-J placement between 2010 and 2020. All PEG tubes were placed with a pull-through technique. The Olympus GIF-N180 endoscope was advanced through the PEG to the jejunum and a Savary-Gilliard guidewire was used for placement of the J-tube extension.
RESULTS: Fifty-eight patients underwent PEG-J placement (median age 61 years; women 52%). Surgically altered gastric anatomy was observed in 11 patients (19%). Median procedure time was 44 min for new PEG-J tube placement (range 26-103) and 20 min for placement of a J-tube extension through an existing PEG tube (range 9-86) or gastrostomy tract. Technical success rate was in 100%. Sixty-two repeat procedures were performed for J-tube exchange in 27 patients (46%, range 1-9 per patient), of which 51 procedures (82%) were done using the same technique. The most common indication for tube replacement was tube dysfunction (63%, n = 39). The median procedure time for tube exchange was 20 min (range 2-62). No major adverse events were encountered.
CONCLUSION: PEG-J tubes can be placed effectively, rapidly, and safely using an ultra-thin caliber endoscope and a stiff steel wire through the PEG tube or mature gastrostomy site, precluding the need for fluoroscopy or oral access. J-tubes can be easily replaced utilizing the same technique.
© 2021. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.

Entities:  

Keywords:  Aspiration; Jejunostomy tubes; N180 endoscope; Savary-Gilliard guidewire

Mesh:

Year:  2021        PMID: 34642797     DOI: 10.1007/s00464-021-08757-8

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   3.453


  2 in total

1.  Percutaneous endoscopic gastrojejunostomy with a tapered tip, nonweighted jejunal feeding tube: improved placement success.

Authors:  M H DeLegge; P Patrick; R Gibbs
Journal:  Am J Gastroenterol       Date:  1996-06       Impact factor: 10.864

2.  Percutaneous endoscopic jejunostomy.

Authors:  J L Ponsky; A Aszodi
Journal:  Am J Gastroenterol       Date:  1984-02       Impact factor: 10.864

  2 in total
  1 in total

1.  Continuously sutured versus linear-stapled anastomosis in robot-assisted hybrid Ivor Lewis esophageal surgery following neoadjuvant chemoradiotherapy: a single-center cohort study.

Authors:  Fiorenzo V Angehrn; Kerstin J Neuschütz; Daniel C Steinemann; Martin Bolli; Lana Fourie; Pauline Becker; Markus von Flüe
Journal:  Surg Endosc       Date:  2022-07-19       Impact factor: 3.453

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.