Gianmarco de Donato1, Edoardo Pasqui2, Giovanni Nano3, Massimo Lenti4, Nicola Mangialardi5, Francesco Speziale6, Mauro Ferrari7, Stefano Michelagnoli8, Matteo Tozzi9, Giancarlo Palasciano2. 1. Department of Vascular Surgery, University of Siena, Siena, Italy. Electronic address: dedonato@unisi.it. 2. Department of Vascular Surgery, University of Siena, Siena, Italy. 3. Department of Vascular Surgery, IRCCS Policlinico San Donato, Milan, Italy. 4. Department of Vascular Surgery, University of Perugia, Perugia, Italy. 5. Department of Vascular Surgery, Ospedale San Camillo, Rome, Italy. 6. Department of Vascular Surgery, La Sapienza University of Rome, Rome, Italy. 7. Department of Vascular Surgery, University of Pisa, Pisa, Italy. 8. Department of Vascular Surgery, Ospedale San Giovanni di Dio, Florence, Italy. 9. Department of Vascular Surgery, University of Insubria, Insubria, Italy.
Abstract
OBJECTIVE: In recent years, manufacturers have developed new stent grafts with lower profiles to increase the endovascular aneurysm repair applicability. As reported by the current European Society for Vascular Surgery guidelines, long-term evaluation of such low-profile platforms is strongly recommended. This study aims to report outcomes beyond 5 years from a multicenter registry, including a real-world cohort of patients electively treated with low-profile stent grafts. METHODS: A retrospective data collection of patients who had undergone elective implantation of low-profile endograft ≤16 Fr. (Zenith LP, Ovation, Incraft) was performed in nine centers. The primary endpoint was a long-term primary clinical success. Secondary endpoints were survival rate, freedom from abdominal aortic aneurysm (AAA)-related death, freedom from type I to III endoleak, limb patency, and freedom from all reinterventions. The Kaplan-Meier curves were stratified for investigative devices. A multivariate analysis evaluated predictors of primary clinical success and reintervention rate. RESULTS: A total of 619 patients were enrolled (Ovation, n = 373; Incraft, n = 111; and Zenith LP, n = 135), with a mean follow-up of 56.8 ± 22.8 months. The overall primary and the secondary clinical success rate at 8 years was 72.1% and 93.8%, respectively. At 8 years, overall survival was 53.2%, freedom from AAA-related death was 94.4%, freedom from reintervention was 74%, freedom from type I/III endoleak was 86.9%, and limb patency was 90.4%. A significantly worse primary clinical success of the Zenith LP was recorded as dependent on more limb-related events. No differences between platforms were registered in the rate of AAA-related deaths, open conversion, sac enlargement, and type I/III endoleaks (P = .26). Multivariate analysis identified iliac tortuosity (hazard ratio, 2.053) and Zenith LP (hazard ratio, 3.818) as significant independent predictors of clinical failure and reintervention. CONCLUSIONS: Low-profile stent grafts have acceptable long-term outcomes. Overall survival and AAA-related death were in line with those reported for traditional devices. Long-term surveillance and reintervention, when necessary, remain crucial to guarantee durability.
OBJECTIVE: In recent years, manufacturers have developed new stent grafts with lower profiles to increase the endovascular aneurysm repair applicability. As reported by the current European Society for Vascular Surgery guidelines, long-term evaluation of such low-profile platforms is strongly recommended. This study aims to report outcomes beyond 5 years from a multicenter registry, including a real-world cohort of patients electively treated with low-profile stent grafts. METHODS: A retrospective data collection of patients who had undergone elective implantation of low-profile endograft ≤16 Fr. (Zenith LP, Ovation, Incraft) was performed in nine centers. The primary endpoint was a long-term primary clinical success. Secondary endpoints were survival rate, freedom from abdominal aortic aneurysm (AAA)-related death, freedom from type I to III endoleak, limb patency, and freedom from all reinterventions. The Kaplan-Meier curves were stratified for investigative devices. A multivariate analysis evaluated predictors of primary clinical success and reintervention rate. RESULTS: A total of 619 patients were enrolled (Ovation, n = 373; Incraft, n = 111; and Zenith LP, n = 135), with a mean follow-up of 56.8 ± 22.8 months. The overall primary and the secondary clinical success rate at 8 years was 72.1% and 93.8%, respectively. At 8 years, overall survival was 53.2%, freedom from AAA-related death was 94.4%, freedom from reintervention was 74%, freedom from type I/III endoleak was 86.9%, and limb patency was 90.4%. A significantly worse primary clinical success of the Zenith LP was recorded as dependent on more limb-related events. No differences between platforms were registered in the rate of AAA-related deaths, open conversion, sac enlargement, and type I/III endoleaks (P = .26). Multivariate analysis identified iliac tortuosity (hazard ratio, 2.053) and Zenith LP (hazard ratio, 3.818) as significant independent predictors of clinical failure and reintervention. CONCLUSIONS: Low-profile stent grafts have acceptable long-term outcomes. Overall survival and AAA-related death were in line with those reported for traditional devices. Long-term surveillance and reintervention, when necessary, remain crucial to guarantee durability.
Authors: Johanna Gruel; Eberhard Grambow; Malte Weinrich; Thomas Heller; Justus Groß; Matthias Leuchter; Mark Philipp Journal: J Clin Med Date: 2022-05-27 Impact factor: 4.964
Authors: Gianmarco de Donato; Edoardo Pasqui; Bruno Gargiulo; Giulia Casilli; Giulia Ferrante; Giuseppe Galzerano; Alessandro Cappelli; Giancarlo Palasciano Journal: Front Cardiovasc Med Date: 2022-02-28