Literature DB >> 34613481

Au@Zr-based metal-organic framework composite as an immunosensing platform for determination of hepatitis B virus surface antigen.

Vivek K Bajpai1, Yuvraj Haldorai2, Imran Khan3, Sonam Sonwal4, Mahendra Pal Singh5, Seema Yadav6, Bilal Ahamad Paray7, Basit Latief Jan8, Sung-Min Kang9, Yun Suk Huh10, Young-Kyu Han11, Shruti Shukla12.   

Abstract

An ultrasensitive electrochemical immunosensor has been prepared using an immunofunctionalized zirconium (Zr)-based metal-organic framework (MOF) with gold (Au) decoration Au@UiO-66(NH2) composite-coated glassy carbon electrode (GCE) for the determination of infectious hepatitis B surface antigen (HBsAg). We fabricated GCE with specific composite via immune-functionalization using anti-HBsAg with Au nanoparticles embedded in UiO-66(NH2). The electrochemical sensing performance of the immunofunctionalized Au@UiO-66(NH2)/GCE with HBsAg was characterized by cyclic voltammetry and differential pulse voltammetry. Under optimized conditions, there was a linear dynamic relationship in the buffer system between the electrical signal and HBsAg levels over the range 1.13 fg mL-1-100 ng mL-1 (R2 = 0.999) with a detection limit of 1.13 fg mL-1. The total analysis time was 15 min per sample. Further validations were performed with HBsAg-spiked human serum samples, and similar detection limits as in the buffer system were observed with reduced signal intensities at lower concentrations of HBsAg (1, 10, and 100 fg mL-1) and minimal interference. The HBsAg electrochemical immunosensing assay had good selectivity and excellent reproducibility, thereby indicating its significant potential in the super-fast diagnosis of hepatitis B.
© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Austria, part of Springer Nature.

Entities:  

Keywords:  Au nanoparticles; Composite glassy carbon electrode; Electrochemical sensing; HBsAg; Hepatitis B ; Immunofunctionalized Au@UiO-66(NH2); Immunosensor ; Voltammetry

Mesh:

Substances:

Year:  2021        PMID: 34613481     DOI: 10.1007/s00604-021-05022-6

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  14 in total

1.  Development and evaluation of an indirect ELISA based on recombinant nonstructural protein 3A to detect antibodies to duck hepatitis A virus type 1.

Authors:  Shan Zhou; Shengyong Zhang; Mingshu Wang; Anchun Cheng; Dekang Zhu; Shun Chen; Mafeng Liu; Xinxin Zhao; Renyong Jia; Qiao Yang; Ying Wu; Shaqiu Zhang; Yunya Liu; Yanling Yu; Ling Zhang; Xiaoyue Chen
Journal:  J Virol Methods       Date:  2019-03-21       Impact factor: 2.014

2.  Liquid gated ZnO nanorod FET sensor for ultrasensitive detection of Hepatitis B surface antigen with vertical electrode configuration.

Authors:  B Chakraborty; S Ghosh; N Das; C RoyChaudhuri
Journal:  Biosens Bioelectron       Date:  2018-09-12       Impact factor: 10.618

3.  Electrochemical detection of T4 polynucleotide kinase based on target-assisted ligation reaction coupled with silver nanoparticles.

Authors:  Yu Jiang; Jinjiang Cui; Tian Zhang; Mingyuan Wang; Guoxing Zhu; Peng Miao
Journal:  Anal Chim Acta       Date:  2019-08-03       Impact factor: 6.558

4.  Label-free amperometric immunosensor for the detection of human serum chorionic gonadotropin based on nanoporous gold and graphene.

Authors:  Ru Li; Dan Wu; He Li; Caixia Xu; Huan Wang; Yanfang Zhao; Yanyan Cai; Qin Wei; Bin Du
Journal:  Anal Biochem       Date:  2011-03-22       Impact factor: 3.365

5.  A label-free electrochemical immunosensor for hepatitis B based on hyaluronic acid-carbon nanotube hybrid film.

Authors:  Diego G A Cabral; Erika C S Lima; Patrícia Moura; Rosa F Dutra
Journal:  Talanta       Date:  2015-10-28       Impact factor: 6.057

Review 6.  Beyond graphene: Electrochemical sensors and biosensors for biomarkers detection.

Authors:  Paolo Bollella; Giovanni Fusco; Cristina Tortolini; Gabriella Sanzò; Gabriele Favero; Lo Gorton; Riccarda Antiochia
Journal:  Biosens Bioelectron       Date:  2016-03-29       Impact factor: 10.618

7.  Direct electrochemistry of cytochrome c immobilized on titanium nitride/multi-walled carbon nanotube composite for amperometric nitrite biosensor.

Authors:  Yuvaraj Haldorai; Seung-Kyu Hwang; Anantha-Iyengar Gopalan; Yun Suk Huh; Young-Kyu Han; Walter Voit; Gopalan Sai-Anand; Kwang-Pill Lee
Journal:  Biosens Bioelectron       Date:  2015-12-19       Impact factor: 10.618

8.  A self-enhanced ECL-RET immunosensor for the detection of CA19-9 antigen based on Ru(bpy)2(phen-NH2)2+ - Amine-rich nitrogen-doped carbon nanodots as probe and graphene oxide grafted hyperbranched aromatic polyamide as platform.

Authors:  Delnia Bahari; Bahareh Babamiri; Abdollah Salimi; Rahman Hallaj; S Mojtaba Amininasab
Journal:  Anal Chim Acta       Date:  2020-07-30       Impact factor: 6.558

9.  Heteroassembled gold nanoparticles with sandwich-immunoassay LSPR chip format for rapid and sensitive detection of hepatitis B virus surface antigen (HBsAg).

Authors:  Jinwoon Kim; Seo Yeong Oh; Shruti Shukla; Seok Bok Hong; Nam Su Heo; Vivek K Bajpai; Hyang Sook Chun; Cheon-Ho Jo; Bong Gill Choi; Yun Suk Huh; Young-Kyu Han
Journal:  Biosens Bioelectron       Date:  2018-02-07       Impact factor: 10.618

10.  Dual labeled mesoporous silica nanospheres based electrochemical immunosensor for ultrasensitive detection of carcinoembryonic antigen.

Authors:  Srinivasan Krishnan; Xinxin He; Fengjuan Zhao; Yuqing Zhang; Shanhu Liu; Ruimin Xing
Journal:  Anal Chim Acta       Date:  2020-08-12       Impact factor: 6.558

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.