Literature DB >> 34605152

Wearable Bifocal Contact Lens for Continual Glucose Monitoring Integrated with Smartphone Readers.

Mohamed Elsherif1, Fahad Alam1, Ahmed E Salih1, Bader AlQattan1, Ali K Yetisen2, Haider Butt1.   

Abstract

Commercial implantable continuous glucose monitoring devices are invasive and discomfort. Here, a minimally-invasive glucose detection system is developed to provide quantitative glucose measurements continually based on bifocal contact lenses. A glucose-sensitive phenylboronic acid derivative is immobilized in a hydrogel matrix and the surface of the hydrogel is imprinted with a Fresnel lens. The glucose-responsive hydrogel is attached to a commercial soft contact lens to be transformed into a bifocal contact lens. The contact lens showed bifocal lengths; far-field focal length originated from the contact lens' curvature, and near-field focal length resulting from the Fresnel lens. When tear glucose increased, the refractive index and groove depth of the Fresnel lens changed, shifting the near-field focal length and the light focusing efficiency. The recorded optical signals are detected at an identical distance far from the contact lens change. The bifocal contact lens allowed for detecting the tear glucose concentration within the physiological range of healthy individuals and diabetics (0.0-3.3 mm). The contact lens rapidly responded to glucose concentration changes and reached 90% of equilibrium within 40 min. The bifocal contact lens is a wearable diagnostic platform for continual biomarker detection at point-of-care settings.
© 2021 The Authors. Small published by Wiley-VCH GmbH.

Entities:  

Keywords:  biomaterials; biophotonics; biosensors; contact lenses; glucose; phenylboronic acid

Mesh:

Substances:

Year:  2021        PMID: 34605152     DOI: 10.1002/smll.202102876

Source DB:  PubMed          Journal:  Small        ISSN: 1613-6810            Impact factor:   13.281


  4 in total

Review 1.  Sense and Learn: Recent Advances in Wearable Sensing and Machine Learning for Blood Glucose Monitoring and Trend-Detection.

Authors:  Ahmad Yaser Alhaddad; Hussein Aly; Hoda Gad; Abdulaziz Al-Ali; Kishor Kumar Sadasivuni; John-John Cabibihan; Rayaz A Malik
Journal:  Front Bioeng Biotechnol       Date:  2022-05-12

2.  Rapid Colorimetric pH-Responsive Gold Nanocomposite Hydrogels for Sensing Applications.

Authors:  Ahmed E Salih; Mohamed Elsherif; Fahad Alam; Matteo Chiesa; Haider Butt
Journal:  Nanomaterials (Basel)       Date:  2022-04-27       Impact factor: 5.719

Review 3.  Wearable Smart Contact Lenses for Continual Glucose Monitoring: A Review.

Authors:  Mohamed Elsherif; Rosalia Moreddu; Fahad Alam; Ahmed E Salih; Israr Ahmed; Haider Butt
Journal:  Front Med (Lausanne)       Date:  2022-04-04

4.  Optical Hydrogel Detector for pH Measurements.

Authors:  Yousef Alqurashi; Mohamed Elsherif; Asail Hendi; Khamis Essa; Haider Butt
Journal:  Biosensors (Basel)       Date:  2022-01-13
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.