Literature DB >> 34600848

Risk Factors for CIED Infection After Secondary Procedures: Insights From the WRAP-IT Trial.

Khaldoun G Tarakji1, Andrew D Krahn2, Jeanne E Poole3, Suneet Mittal4, Charles Kennergren5, Mauro Biffi6, Panagiotis Korantzopoulos7, Paolo Domenico Dallaglio8, Daniel R Lexcen9, Jeff D Lande9, Gregory Hilleren9, Reece Holbrook9, Bruce L Wilkoff10.   

Abstract

OBJECTIVES: This study aimed to identify risk factors for infection after secondary cardiac implantable electronic device (CIED) procedures.
BACKGROUND: Risk factors for CIED infection are not well defined and techniques to minimize infection lack supportive evidence. WRAP-IT (World-wide Randomized Antibiotic Envelope Infection Prevention trial), a large study that assessed the safety and efficacy of an antibacterial envelope for CIED infection reduction, offers insight into procedural details and infection prevention strategies.
METHODS: This analysis included 2,803 control patients from the WRAP-IT trial who received standard preoperative antibiotics but not the envelope (44 patients with major infections through all follow-up). A multivariate least absolute shrinkage and selection operator machine learning model, controlling for patient characteristics and procedural variables, was used for risk factor selection and identification. Risk factors consistently retaining predictive value in the model (appeared >10 times) across 100 iterations of imputed data were deemed significant.
RESULTS: Of the 81 variables screened, 17 were identified as risk factors with 6 being patient/device-related (nonmodifiable) and 11 begin procedure-related (potentially modifiable). Patient/device-related factors included higher number of previous CIED procedures, history of atrial arrhythmia, geography (outside North America and Europe), device type, and lower body mass index. Procedural factors associated with increased risk included longer procedure time, implant location (non-left pectoral subcutaneous), perioperative glycopeptide antibiotic versus nonglycopeptide, anticoagulant, and/or antiplatelet use, and capsulectomy. Factors associated with decreased risk of infection included chlorhexidine skin preparation and antibiotic pocket wash.
CONCLUSIONS: In WRAP-IT patients, we observed that several procedural risk factors correlated with infection risk. These results can help guide infection prevention strategies to minimize infections associated with secondary CIED procedures.
Copyright © 2022 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  cardiac resynchronization therapy; implantable cardioverter defibrillator; machine learning; pacemaker; procedure

Mesh:

Year:  2021        PMID: 34600848     DOI: 10.1016/j.jacep.2021.08.009

Source DB:  PubMed          Journal:  JACC Clin Electrophysiol        ISSN: 2405-500X


  3 in total

Review 1.  Antibiotic-Eluting Envelopes for the Prevention of Cardiac Implantable Electronic Device Infections: Rationale, Efficacy, and Cost-Effectiveness.

Authors:  Vassil Traykov; Carina Blomström-Lundqvist
Journal:  Front Cardiovasc Med       Date:  2022-03-28

Review 2.  Surgical Applications of Materials Engineered with Antimicrobial Properties.

Authors:  David P Perrault; Ayushi Sharma; Jessica F Kim; Geoffrey C Gurtner; Derrick C Wan
Journal:  Bioengineering (Basel)       Date:  2022-03-26

Review 3.  Cardiac Implantable Electronic Devices Infection Assessment, Diagnosis and Management: A Review of the Literature.

Authors:  Filippo Toriello; Massimo Saviano; Andrea Faggiano; Domitilla Gentile; Giovanni Provenzale; Alberto Vincenzo Pollina; Elisa Gherbesi; Lucia Barbieri; Stefano Carugo
Journal:  J Clin Med       Date:  2022-10-06       Impact factor: 4.964

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.