Literature DB >> 34583351

Nerve Hypertrophy and Altered Diffusion in Anti-Myelin-Associated Glycoprotein Neuropathy Detected by Brachial Plexus Magnetic Resonance Neurography.

Kyosuke Koide1, Atsuhiko Sugiyama2, Hajime Yokota3, Hiroki Mukai4, Jiaqi Wang2, Keigo Nakamura2, Sonoko Misawa2, Shoichi Ito2,5, Satoshi Kuwabara2.   

Abstract

INTRODUCTION: This study assessed the morphological changes and diffusion tensor imaging (DTI)-derived parameters of the brachial plexus using magnetic resonance neurography (MRN) in patients with anti-myelin-associated glycoprotein (anti-MAG) neuropathy.
METHODS: Eight patients with anti-MAG neuropathy underwent MRN of the brachial plexus with 3-dimensional (3D) short tau inversion recovery (STIR) and DTI sequences. Two neuroradiologists and a neurologist qualitatively assessed nerve hypertrophy on 3D STIR MRN. The cross-sectional area (CSA) of the nerve roots was measured. Quantitative analyses of fractional anisotropy (FA) and axial, radial, and mean diffusivity (AD, RD, and MD) were obtained after postprocessing on DTI and manual segmentation.
RESULTS: There was nerve hypertrophy in 37.5% of the patients with anti-MAG neuropathy. All patients with anti-MAG neuropathy with nerve hypertrophy were refractory to rituximab therapy. The CSA of the nerve roots was inversely correlated with FA and positively correlated with MD and RD. FA decreased in the nerve roots and inversely correlated with disease duration.
CONCLUSIONS: Nerve hypertrophy appears in the proximal portion of peripheral nerves, such as the brachial plexus, in patients with anti-MAG neuropathy. Altered diffusion in the nerve roots might be associated with the loss of myelin integrity due to the demyelination process in anti-MAG neuropathy.
© 2021 S. Karger AG, Basel.

Entities:  

Keywords:  Diffusion tensor imaging; Magnetic resonance imaging; Myelin-associated glycoprotein; Rituximab

Mesh:

Year:  2021        PMID: 34583351     DOI: 10.1159/000519128

Source DB:  PubMed          Journal:  Eur Neurol        ISSN: 0014-3022            Impact factor:   1.710


  2 in total

1.  Value of High-Resolution MRI in the Diagnosis of Brachial Plexus Injury in Infants and Young Children.

Authors:  Qun Lao; Yuzhu Jia; Kaiyu Zhao; Kun Liu; Jianju Feng
Journal:  Int J Gen Med       Date:  2022-06-18

2.  Clinical Application of Diffusion Tensor Imaging for a Brachial Plexus Injury.

Authors:  Giulio Vara; Gianmarco Tuzzato; Giuseppe Bianchi; Marco Miceli; Luca Spinardi; Rita Golfieri; Raffaella Rinaldi; Giancarlo Facchini
Journal:  Diagnostics (Basel)       Date:  2022-07-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.