Unreacted monomers eluted from resin-based restorative materials have been considered a reason of local and systemic adverse reactions. This study was designed to determine the effect of finishing and polishing procedures on the elution of Bis-GMA, TEGDMA, UDMA, and HEMA monomers from compomer and bulk-fill composite resins. Bulk-fill composite (3M ESPE GmbH, Seefeld, Germany) and compomer (Dentsply DeTrey GmbH, Konstanz, Germany) specimens with 3 × 4 mm diameters were prepared. The specimens were randomly divided into two groups, and finishing-polishing procedures were applied only to the experimental groups. Release of residual monomers was analyzed by using High-Performance Liquid Chromatography (HPLC) after 24, 48, and 72 hours. Repeated measures ANOVA and Tukey post hoc tests were used for comparisons. Finishing and polishing procedures had a significant effect on reducing the quantity of UDMA release in the Filtek™ Bulk Fill composite and Bis-GMA, HEMA, and TEGDMA in the Dyract XP compomer (p < 0.05). The restorative materials investigated here are not chemically stable after polymerization, and concentrations of eluted monomers may reach critical toxicity levels even after one restoration placement. Finishing and polishing procedures are mandatory to reduce residual monomers.Entities:
Mesh:
Substances:
Year: 2021 PMID: 34580639 PMCID: PMC8464417 DOI: 10.1155/2021/6316171
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Restorative materials used in the study.
| Material type | Material | Composition | Manufacturer |
|---|---|---|---|
| Compomer | Dyract XP compomer | (i) Urethane dimethacrylate (UDMA) | Dentsply DeTrey GmbH, Konstanz, Germany |
| Bulk-fill composite | Filtek™ Bulk Fill composite | (i) Aromatic dimethacrylate (AUDMA) | 3M ESPE GmbH, Seefeld, Germany |
Regression equations of the calibration curves, detection limits, and retention times of the monomers.
| Regression equation |
| LOD ( | LOQ ( | Retention time (minute) | |
|---|---|---|---|---|---|
| Bis-GMA | 0.9978 | 0.680 | 2.053 | 2.85 | |
| TEGDMA | 0.9997 | 0.788 | 2.363 | 2.32 | |
| HEMA | 0.9999 | 0.482 | 1.445 | 1.82 | |
| UDMA | 0.9999 | 0.412 | 1.236 | 2.59 |
LOD: limit of detection; LOQ: limit of quantitation.
Mean values and standard deviations (±SD) of UDMA (μg/mL) eluted from restorative materials.
| Dyract XP- | Dyract XP+ | Filtek™ Bulk Fill- | Filtek™ Bulk Fill+ | |
|---|---|---|---|---|
| 24hours | 3.981 ± 0.260aA (0.0084) | 1.630 ± 0.348aA (0.0034) | 65.682 ± 6.078bA (0.1395) | 23.898 ± 14.356cA (0.0507) |
| 48 hours | 4.746 ± 0.354aA (0.01) | 1.993 ± 0.533aA (0.0042) | 85.974 ± 18.299bB (0.1826) | 26.090 ± 15.577cA (0.0554) |
| 72 hours | 4.547 ± 0.592aA (0.0096) | 2.304 ± 0.329aA (0.0048) | 89.101 ± 9.325bB (0.1893) | 30.212 ± 16.750cA (0.0641) |
Different superscript uppercase letters indicate a significant difference (p < 0.05) within the same column; different superscript lowercase letters indicate a significant difference (p < 0.05) within the same row (Tukey post hoc test). The numbers in parentheses are expressed as mmol/L.
Mean values and standard deviations (±SD) of HEMA (μg/mL) eluted from restorative materials.
| Dyract XP- | Dyract XP+ | Filtek™ Bulk Fill- | Filtek™ Bulk Fill+ | |
|---|---|---|---|---|
| 24 hours | 36.939 ± 1.413bA (0.2838) | 14.473 ± 1.805aA (0.1112) | 5.281 ± 0.481a (0.0405) | 3.344 ± 0.943a (0.0256) |
| 48 hours | 44.418 ± 2.240aAC (0.3413) | 18.769 ± 3.518bA (0.1442) | Below LOD | Below LOD |
| 72 hours | 49.939 ± 3.811aBC (0.3837) | 24.238 ± 2.504bA (0.1862) | Below LOD | Below LOD |
Different superscript uppercase letters indicate a significant difference (p < 0.05) within the same column; different superscript lowercase letters indicate a significant difference (p < 0.05) within the same row (Tukey post hoc test). The numbers in parentheses are expressed as mmol/L. LOD: limit of detection.
Mean values and standard deviations (±SD) of Bis-GMA (μg/mL) eluted from restorative materials.
| Dyract XP- | Dyract XP+ | Filtek™ Bulk Fill- | Filtek™ Bulk Fill+ | |
|---|---|---|---|---|
| 24 hours | 30.209 ± 0.895bA (0.0589) | 15.386 ± 2.058aA (0.03) | 8.996 ± 0.721aA (0.017) | 4.482 ± 2.255aA (0.0087) |
| 48 hours | 37.401 ± 2.135bAC (0.0729) | 20.306 ± 3.261cdA (0.0396) | 12.509 ± 1.580adA (0.0244) | 5.674 ± 2.289aA (0.011) |
| 72 hours | 42.312 ± 3.823bBC (0.0825) | 25.435 ± 1.699cdA (0.0498) | 15.317 ± 2.113adA (0.0298) | 10.278 ± 4.011aA (0.02) |
Different superscript uppercase letters indicate a significant difference (p < 0.05) within the same column; different superscript lowercase letters indicate a significant difference (p < 0.05) within the same row (Tukey post hoc test). The numbers in parentheses are expressed as mmol/L.
Mean values and standard deviations (±SD) of TEGDMA (μg/mL) eluted from restorative materials.
| Dyract XP- | Dyract XP+ | Filtek™ Bulk Fill- | Filtek™ Bulk Fill+ | |
|---|---|---|---|---|
| 24 hours | 20.249 ± 0.943aA (0.0707) | 6.342 ± 1.310bA (0.022) | Below LOD | Below LOD |
| 48 hours | 22.137 ± 0.806aA (0.0773) | 7.667 ± 1.794bA (0.0267) | Below LOD | Below LOD |
| 72 hours | 24.476 ± 3.323aA (0.0854) | 9.791 ± 1.145bA (0.0341) | Below LOD | Below LOD |
Different superscript uppercase letters indicate a significant difference (p < 0.05) within the same column; different superscript lowercase letters indicate a significant difference (p < 0.05) within the same row (Tukey post hoc test). The numbers in parentheses are expressed as mmol/L. LOD: limit of detection.
Figure 1Graphical view of UDMA release from tested restorative materials.
Figure 2Graphical view of HEMA release from tested restorative materials.
Figure 3Graphical view of Bis-GMA release from tested restorative materials.
Figure 4Graphical view of TEGDMA release from tested restorative materials.