Literature DB >> 34568967

Cemented radial head arthroplasty: Does radiographic loosening have an effect on clinical and functional outcomes? Average 10 years' results.

Tuna Pehlivanoglu1,2, Ali Erşen3, Serkan Bayram4, Ata Can Atalar5, Mehmet Demirhan6.   

Abstract

PURPOSE: The aim of this study was to evaluate the possible effect of radiographic loosening on clinical and functional outcomes, while presenting the mid-term radiographic and functional outcomes of cemented, monopolar RHA applied to patients with comminuted radial head fractures.
METHODS: We performed a retrospective study by evaluating the records of patients who were diagnosed in a single center with radial head fractures between 2001 and 2013. Twenty-six patients with comminuted radial head fractures with a mean age of 48.9 and a mean follow-up time of 132.2 months were included. The radiographic evaluation was performed by assessing peri-prosthetic radiolucent lines around the stem to evaluate loosening, while the clinical evaluation was performed by utilizing elbow range of motion (ROM), Mayo elbow performance score (MEPS), Oxford elbow score (OES) and quick-DASH scores.
RESULTS: 13 patients (Group 1) with peri-prosthetic stem lucency were defined as radiographic loosening (50%), while the remaining 13 patients (Group 2) were not detected to have stem lucency. One patient in group 1 also had concomitant pain and underwent removal of the prosthesis, while 12 patients (92.3%) remained pain-free. On the latest follow-up visit, there was no significant difference between the groups regarding ROM, MEPS, OES and quick-DASH scores.
CONCLUSIONS: Within ten years following surgery, half of the patients with radial head prostheses were noted to show radiographic signs of loosening which did not have any major negative effect in terms of clinical-functional outcomes and quality of life, except requiring the removal of the implant in one patient. LEVEL OF EVIDENCE: Level III.
© 2021. The Author(s), under exclusive licence to Springer-Verlag France SAS, part of Springer Nature.

Entities:  

Keywords:  Cemented monopolar radial head prosthesis; Comminuted radial head fracture; Functional scores; Radiographic loosening; Stem lucency

Year:  2021        PMID: 34568967     DOI: 10.1007/s00590-021-03129-3

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  3 in total

Review 1.  [Primary radial head arthroplasty in trauma : Complications].

Authors:  K Schmidt-Horlohé; S Buschbeck; D Wincheringer; M Weißenberger; R Hoffmann
Journal:  Orthopade       Date:  2016-10       Impact factor: 1.087

2.  Midterm results with a bipolar radial head prosthesis: radiographic evidence of loosening at the bone-cement interface.

Authors:  Nebojsa Popovic; Roger Lemaire; Pierre Georis; Philippe Gillet
Journal:  J Bone Joint Surg Am       Date:  2007-11       Impact factor: 5.284

3.  A follow-up of one hundred cases of fracture of the head of the radius with a review of the literature.

Authors:  G W JOHNSTON
Journal:  Ulster Med J       Date:  1962-06-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.