Jakob Pansell1,2, Max Bell2,3, Peter Rudberg2,3, Ola Friman2, Charith Cooray1,4. 1. Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden. 2. Department of Anesthesia and Intensive Care Medicine, Karolinska University Hospital, Stockholm, Sweden. 3. Department of Physiology & Pharmacology, Karolinska Institutet, Stockholm, Sweden. 4. Department of Clinical Neurophysiology, Karolinska University Hospital, Stockholm, Sweden.
Abstract
BACKGROUND AND PURPOSE: Treatment of elevated intracranial pressure (ICP) is central to neurocritical care, but not all patients are eligible for invasive ICP-monitoring. A promising noninvasive option is ultrasound measurement of the optic nerve sheath diameter (ONSD). However, meta-analyses of ONSD for elevated ICP show wide confidence intervals. This might be due to baseline variations, inter-rater variability, and varying measurement methods. No standardized protocol has been validated. Corrections for eyeball diameter (ED) and optic nerve diameter (OND) may compensate for baseline variations. We evaluated a protocol and compared two different measurement methods for ONSD ultrasound. METHODS: Two operators, blinded to each other's measurements, measured ONSD, ED, and OND twice in 20 patients. ONSD was measured with two different methods in use: internal (ONSDint) or external (ONSDext) of the dura mater. Intra-class correlation (ICC) was calculated for inter-rater and intra-rater reliability. RESULTS: ICCs for inter-rater reliability of ONSDext and ONSDint (95% confidence interval) were 0.96 (0.93, 0.98) and 0.88 (0.79, 0.94), respectively. ICCs for intra-rater reliability of ONSDext and ONSDint were 0.97 (0.94, 0.99) and 0.93 (0.87, 0.96), respectively. There was no significant bias or difference in intra-rater reliability between operators. CONCLUSIONS: ONSD can be measured with an excellent inter- and intra-rater reliability and low risk of inter-rater bias, when using this protocol. ONSDext yields a higher inter- and intra-rater reliability than ONSDint. Corrections for ED and OND can be performed reliably.
BACKGROUND AND PURPOSE: Treatment of elevated intracranial pressure (ICP) is central to neurocritical care, but not all patients are eligible for invasive ICP-monitoring. A promising noninvasive option is ultrasound measurement of the optic nerve sheath diameter (ONSD). However, meta-analyses of ONSD for elevated ICP show wide confidence intervals. This might be due to baseline variations, inter-rater variability, and varying measurement methods. No standardized protocol has been validated. Corrections for eyeball diameter (ED) and optic nerve diameter (OND) may compensate for baseline variations. We evaluated a protocol and compared two different measurement methods for ONSD ultrasound. METHODS: Two operators, blinded to each other's measurements, measured ONSD, ED, and OND twice in 20 patients. ONSD was measured with two different methods in use: internal (ONSDint) or external (ONSDext) of the dura mater. Intra-class correlation (ICC) was calculated for inter-rater and intra-rater reliability. RESULTS: ICCs for inter-rater reliability of ONSDext and ONSDint (95% confidence interval) were 0.96 (0.93, 0.98) and 0.88 (0.79, 0.94), respectively. ICCs for intra-rater reliability of ONSDext and ONSDint were 0.97 (0.94, 0.99) and 0.93 (0.87, 0.96), respectively. There was no significant bias or difference in intra-rater reliability between operators. CONCLUSIONS: ONSD can be measured with an excellent inter- and intra-rater reliability and low risk of inter-rater bias, when using this protocol. ONSDext yields a higher inter- and intra-rater reliability than ONSDint. Corrections for ED and OND can be performed reliably.
Authors: Livio Vitiello; Giulio Salerno; Maddalena De Bernardo; Olga D'Aniello; Luigi Capasso; Giuseppe Marotta; Nicola Rosa Journal: Front Med (Lausanne) Date: 2022-06-30