Literature DB >> 34551858

An Automated Electronic Screening Tool (DETECT) for the Detection of Potentially Irreversible Loss of Brain Function.

Anne Trabitzsch1, Konrad Pleul, Kristian Barlinn, Volkmar Franz, Markus Dengl, Monica Götze, Andreas Güldner, Maria Eberlein-Gonska, Detlev Michael Albrecht, Christian Hugo.   

Abstract

BACKGROUND: A major reason for the low number of organ donors in Germany is a deficit in the recognition of patients who may have impending irreversible loss of brain function (ILBF) in hospitals capable of organ retrieval.
METHODS: We used anonymized data from the German Organ Procurement Organization (Deutsche Stiftung Organtransplantation, DSO) to compare two 12-month periods (a reference period and an evaluation period) before and after the implementation of an electronic screening tool (DETECT) at the University Hospital Dresden (UKD) with four other university hospitals without tool implementation (comparative cohort). DETECT is intended to aid in the recognition of potentially impending ILBF. The study endpoints encompassed patients with potentially unrecognized ILBF, patients with recognized ILBF, organ donations performed, and reports to the DSO. Changes in absolute risk were compared with Breslow-Day tests.
RESULTS: 309 patients who died with primary or secondary brain lesions were identified in the UKD in the reference and evaluation periods (164 and 145 patients, respectively), and 1060 (529, 531) in the comparative cohort. In the UKD, the number of unrecognized cases of possibly impending ILBF was 14/164 (8.54%) in the reference period and 1/145 (0.69%) in the evaluation period, yielding an absolute reduction of 7.85% (95% confidence interval [--3.36; --12.33]); by contrast, in the comparative cohort, there was a 0.55% absolute increase between the two periods ([--2.21; 3.30]; p = 0.002 for the comparison between the two cohorts). Only minor differences in absolute risk change were seen with regard to the probability of recognized ILBF (7.09% [0.29; 13.88] vs. 2.42% [1.18; 6.01]; p = 0.234), organ donation (4.70% [--0.89; 10.28] vs. 0.55% [--2.17; 3.26]; p = 0.214), or reporting to the DSO (4.17% [--1.77; 10.11] vs. 2.22% [--1.44; 5.89; p = 0.447); these changes may have arisen by chance.
CONCLUSION: These findings suggest that the use of DETECT can help to reduce the deficit in the recognition of patients with impending or manifest ILBF.

Entities:  

Mesh:

Year:  2021        PMID: 34551858      PMCID: PMC8743991          DOI: 10.3238/arztebl.m2021.0307

Source DB:  PubMed          Journal:  Dtsch Arztebl Int        ISSN: 1866-0452            Impact factor:   8.251


  8 in total

1.  Decline in Organ Donation in Germany.

Authors:  Kevin Schulte; Christoph Borzikowsky; Axel Rahmel; Felix Kolibay; Nina Polze; Patrick Fränkel; Susanne Mikle; Benedikt Alders; Ulrich Kunzendorf; Thorsten Feldkamp
Journal:  Dtsch Arztebl Int       Date:  2018-07-09       Impact factor: 5.594

2.  The life-years saved by a deceased organ donor.

Authors:  Mark A Schnitzler; James F Whiting; Daniel C Brennan; Krista L Lentine; Niraj M Desai; William Chapman; Kevin C Abbott; Zoltan Kalo
Journal:  Am J Transplant       Date:  2005-09       Impact factor: 8.086

3.  [How many potential organ donors are there really? : Retrospective analysis of why determination of irreversible loss of brain function was not performed in deceased patients with relevant brain damage].

Authors:  M Brauer; A Günther; K Pleul; M Götze; C Wachsmuth; T Meinig; M Bauer; O W Witte; A Rahmel
Journal:  Anaesthesist       Date:  2018-11-16       Impact factor: 1.041

4.  Palliative ICU beds for potential organ donors: an effective use of resources based on quality-adjusted life-years gained.

Authors:  Leo Nunnink; David A Cook
Journal:  Crit Care Resusc       Date:  2016-03       Impact factor: 2.159

Review 5.  Clinical monitoring scales in acute brain injury: assessment of coma, pain, agitation, and delirium.

Authors:  Richard R Riker; Jennifer E Fugate
Journal:  Neurocrit Care       Date:  2014-12       Impact factor: 3.210

Review 6.  Intimacy or utility? Organ donation and the choice between palliation and ventilation.

Authors:  Aric Bendorf; Ian H Kerridge; Cameron Stewart
Journal:  Crit Care       Date:  2013-05-23       Impact factor: 9.097

7.  Evaluation of underidentification of potential organ donors in German hospitals.

Authors:  Grit Esser; Benedikt Kolbrink; Christoph Borzikowsky; Ulrich Kunzendorf; Thorsten Feldkamp; Kevin Schulte
Journal:  PLoS One       Date:  2020-11-19       Impact factor: 3.240

  8 in total
  3 in total

1.  In Reply.

Authors:  Christian Hugo
Journal:  Dtsch Arztebl Int       Date:  2022-04-01       Impact factor: 8.251

2.  DETECT Should Force Us To Think About the Situation of Our ICUs.

Authors:  Reiner Klick
Journal:  Dtsch Arztebl Int       Date:  2022-04-01       Impact factor: 8.251

Review 3.  [Organ donation-Not only a responsibility of intensive care medicine].

Authors:  A Rand; T Koch; M Ragaller
Journal:  Anaesthesist       Date:  2021-12-06       Impact factor: 1.052

  3 in total