Interventions required by policymakers or local authorities
| Monitor gas testing facilities, laboratories, and calibration facilities at the site | |
| To ensure compliance and procedures of finished gas for its quality | |
| Purity and grade (ultra-pure, 99.999% minimum) should be maintained | |
| A random check of tankers and especially cylinders for chemical analysis of oxygen gases | |
| Impurity parameters certificate should be provided for the levels (i.e., carbon monoxide/carbon dioxide, moisture, arsenic, oil, halogen, oxidizing substances, acidity or alkalinity, argon, hydrocarbons) | |
| Test results can be cross-checked by the local authority for any foreign materials, moisture, and contaminants | |
| To monitor any misuse of other cylinders (i.e., helium, hydrogen, acetylene, argon) for refilling oxygen without proper cleaning and conditioning | |
| Monitoring for the sanitization of oxygen supply (pipeline and tubes) for unwanted fungal growth | |
| Special attention should be given to test “black fungus” (mucormycosis) infection among recovered patients | |
| Checking/advisory for black fungus on patients on oxygen support should be made an essential part of the COVID-19 control protocol at every level | |
| Special attention/care should be given to comorbid and patients using the steroid to check the fungal infection for the hidden cause of death |
Recommendation/awareness needed for the general public
| Oxygen gas cylinder should be kept at normal room temperature | |
| Always use distilled water to make oxygen hydrated before use | |
| Never use poor-quality water such as tap water, boiled water, or purified RO water | |
| Masks, nasal cannulae should be cleaned and checked for any leakage by the attendee | |
| If using an oxygen concentrator, attendee should adhere to manufacturer guidelines for proper cleaning as and when required | |
| The oxygen concentrator should be placed in a well-ventilated and clean area | |
| Oxygen filters should be properly cleaned from time to time | |