Literature DB >> 3451756

Determination of cardiac output by ultrafast computed tomography.

C J Wolfkiel1, J L Ferguson, E V Chomka, W R Law, B H Brundage.   

Abstract

Three methods of determining cardiac output were compared in six anesthetized dogs (23-28 kg) for the purpose of evaluating the ability of ultrafast computed tomography to measure cardiac output at three points of the circulation: pulmonary artery, left ventricle, and descending aorta. Computed tomography cardiac output is calculated by indicator dilution analysis of an iodinated contrast bolus time-density curve. Computed tomography cardiac output was compared to thermodilution and radioactive microsphere cardiac output methods. The results show very good agreement between thermodilution and computed tomography methods (r = .90) and good agreement between microsphere and computed tomography (r = .88). Comparison of computed tomography cardiac output measurements from the left ventricle and pulmonary artery was excellent (r = .99), as were measurements from the left ventricle and descending aorta (r = .97). This study also showed minimal interlevel scan-density response variability (3%) and minimal variability between experiments (7%). Therefore, it is concluded that cardiac output can be accurately measured at many points in the blood pool by ultrafast computed tomography.

Entities:  

Mesh:

Year:  1986        PMID: 3451756

Source DB:  PubMed          Journal:  Am J Physiol Imaging        ISSN: 0885-8276


  5 in total

1.  Measurement of cardiac output from a test-bolus injection in multislice computed tomography.

Authors:  Andreas H Mahnken; Ernst Klotz; Anja Hennemuth; Bettina Jung; Ralf Koos; Joachim E Wildberger; Rolf W Günther
Journal:  Eur Radiol       Date:  2003-08-06       Impact factor: 5.315

Review 2.  Ultrafast CT and the cardiovascular system.

Authors:  M S Bleiweis; D Georgiou; B H Brundage
Journal:  Int J Card Imaging       Date:  1992

Review 3.  Measurement of myocardial blood flow by UFCT: towards clinical applicability.

Authors:  C J Wolfkiel; B H Brundage
Journal:  Int J Card Imaging       Date:  1991

4.  Accurate measures of left ventricular ejection fraction using electron beam tomography: a comparison with radionuclide angiography, and cine angiography.

Authors:  H K Baik; M J Budoff; K L Lane; H Bakhsheshi; B H Brundage
Journal:  Int J Card Imaging       Date:  2000-10

Review 5.  Quantitative evaluation of regional myocardial perfusion using fast X-ray computed tomography.

Authors:  A Schmermund; M R Bell; L O Lerman; E L Ritman; J A Rumberger
Journal:  Herz       Date:  1997-02       Impact factor: 1.443

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.