Literature DB >> 34505924

Mid-term results of the Remeex® readjustable sling for female complex stress urinary incontinence and sonographic hypomobile urethra.

Cristina Ros1, Sílvia Escura2, Sònia Anglès-Acedo2, Marta Larroya2, Eduardo Bataller2, Lluís Amat3, Emília Sánchez2, Montserrat Espuña-Pons2, Francisco Carmona2.   

Abstract

INTRODUCTION AND HYPOTHESIS: We aimed to evaluate the results of a readjustable sling (Remeex® system) among a selected group of women with complex stress urinary incontinence (SUI) with sonographic hypomobile urethra and assessing failure-related risk factors.
METHODS: Observational, longitudinal, prospective cohort study, including patients who underwent surgery with the Remeex® system. The primary outcome was a binary outcome in change of one level or more of the severity of urinary incontinence symptoms according to the intervals of the Incontinence Questionnaire-Short Form (ICIQ-UI-SF) score (mild, moderate, severe and very severe). Secondary outcomes were postsurgical complications, absolute ICIQ-UI-SF, 24-h pad weight test (24-h PT), urodynamic SUI and Patient Global Impression of Improvement (PGI-I) score to evaluate subjective success.
RESULTS: Among 120 women included, after surgery we found a 70% subjective success rate, a 76.7% decrease of urinary incontinence severity and a mean reduction of the 24-h PT of 109.6 ± 291.4 g. Women with post-surgical decreased severity of incontinence had lower mean body mass index (BMI) and 24-h PT than those without incontinence severity changes with statistically significant differences (p = 0.028 and p = 0.027, respectively). A logistic regression model demonstrated that a 1-point increase of BMI increased the risk of persistence of incontinence severity after surgery by 19% (OR = 1.19; 95% CI: 1.01-1.41; p = 0.040), and an increase of 10 g in the pre-surgical 24-h PT represented a 3% rise of the aforementioned risk (OR = 1.03; 95% CI: 1.01-1.06; p = 0.034).
CONCLUSIONS: In patients with complex SUI and sonographic hypomobile urethra, use of a readjustable sling (Remeex® system) led to improvement of SUI. Patients with a greater BMI and pre-surgical 24-h PT showed worse results after surgery.
© 2021. The International Urogynecological Association.

Entities:  

Keywords:  Hypomobile urethra; Mid-urethral sling; Readjustable sling; Recurrent stress urinary incontinence; Ultrasound

Mesh:

Year:  2021        PMID: 34505924     DOI: 10.1007/s00192-021-04972-y

Source DB:  PubMed          Journal:  Int Urogynecol J        ISSN: 0937-3462            Impact factor:   2.894


  1 in total

1.  The evolution of stress urinary incontinence treatment techniques of the last three decades.

Authors:  Cassio Luis Zanettini Riccetto
Journal:  Int Braz J Urol       Date:  2022 Jul-Aug       Impact factor: 3.050

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.