Literature DB >> 3449786

Hepatic perfusion index in cirrhotic livers--investigation of imaging and analytical procedures.

B Leng1, M P O'Driscoll, F A Majeed, J S Grime, M Critchley.   

Abstract

Dynamic hepatic scintigraphy was performed in a group of cirrhotic patients to evaluate the optimum imaging and analytical procedures necessary for the measurement of the hepatic perfusion index (HPI). Patients were studied in the posterior (n = 19) and the anterior (n = 14), positions, with either 0.2 or 0.5 ml of 99Tcm sulphur colloid administered as a rapid bolus injection. In each subject, three ROIs (small, medium and large) were drawn over the liver, and time-activity perfusion curves were generated. Analytical techniques were developed to allow flexibility in selecting the arterial and portal venous phases of the liver perfusion curve. The quality of the bolus, expressed as the full width at half-maximum of the left ventricular time--activity curve, was independent of the bolus volumes and patient positioning. The dispersion in the data and the inter-observer variation were less in the anterior view using medium and large ROIs, compared with the anterior small ROI and all the posterior ROI sizes. A time delay between liver and kidney arterial phases, if ignored, produced statistically significant effects on the values of the HPI. We conclude that HPI investigations are best performed in the anterior projection. Data analysis using a large liver ROI is preferred, and flexible data-processing techniques are recommended, particularly in the presence of a liver and kidney arterial time delay.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3449786     DOI: 10.1097/00006231-198712000-00009

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  3 in total

1.  Scintigraphic evaluation of hepatic blood flow after intrahepatic portosystemic shunt (TIPS).

Authors:  J Menzel; O Schober; P Reimer; W Domschke
Journal:  Eur J Nucl Med       Date:  1997-06

2.  Detection of hepatic metastases using duplex/color Doppler sonography.

Authors:  E Leen; J A Goldberg; J Robertson; G R Sutherland; D M Hemingway; T G Cooke; C S McArdle
Journal:  Ann Surg       Date:  1991-11       Impact factor: 12.969

3.  Clinical correlation of high activity dynamic hepatic scintigraphy in patients with colorectal cancer.

Authors:  D M Hemingway; T G Cooke; G McCurrach; R G Bessent; R Carter; J H McKillop; C S McArdle
Journal:  Br J Cancer       Date:  1992-05       Impact factor: 7.640

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.