Literature DB >> 34478240

Evidence-based diagnostic performance of novel biomarkers for the diagnosis of malignant mesothelioma in effusion cytology.

Ilaria Girolami1, Ersilia Lucenteforte2, Albino Eccher3, Stefano Marletta4, Matteo Brunelli4, Paolo Graziano5, Pasquale Pisapia6, Umberto Malapelle6, Giancarlo Troncone6, Aldo Scarpa3,4, Tao Huang7, Liron Pantanowitz7.   

Abstract

Cytology effusions are often the only material available for diagnosing malignant pleural mesothelioma (MPM). However, the cytomorphological features alone are not always diagnostic, and cytology samples preclude an assessment for pleural tissue invasion. Accordingly, immunohistochemical, soluble, and molecular biomarkers have been developed. The aim of this study is to provide quantitative evidence regarding the diagnostic performance of novel biomarkers. To that end, a systematic literature review was performed of articles dealing with a loss of BRCA1-associated protein 1 (BAP1), methylthioadenosine (MTAP), 5-hydroxymethylcitosine (5-hmC), glucose transporter 1 (GLUT1), insulin like-growth factor II messenger RNA-binding protein 3 (IMP3), enhanced zeste homologue 2 (EZH2) staining, cyclin-dependent kinase inhibitor 2A (CDKN2A) homozygous deletion (HD) testing, soluble mesothelin, and microRNA quantification in cytological samples for the diagnosis of MPM versus reactive atypical mesothelial cells. Sensitivity and specificity were extracted, and a meta-analysis was performed. The quality of the studies was assessed with Quality Assessment of Diagnostic Accuracy Studies 2, and the quality of the evidence was evaluated with the Grading of Recommendations Assessment, Development, and Evaluation approach. Seventy-one studies were included. BAP1 loss showed a sensitivity of 0.65 (confidence interval [CI], 0.59-0.71) and a specificity of 0.99 (CI, 0.93-1.00). MTAP loss and p16 HD showed 100% specificity with sensitivities of 0.47 (CI, 0.38-0.57) and 0.62 (CI, 0.53-0.71), respectively. BAP1 loss and CDKN2A HD combined showed maximal specificity and a sensitivity of 0.83 (CI, 0.78-0.89). GLUT1 and IMP3 showed sensitivities of 0.82 (CI, 0.70-0.90) and 0.65 (CI, 0.41-0.90), respectively, with comparable specificity. Mesothelin showed a sensitivity of 0.73 (CI, 0.68-0.77) and a specificity of 0.90 (CI, 0.84-0.93). In conclusion, some of the recently emerging biomarkers are close to 1.00 specificity. Their moderate sensitivity on their own, however, can be significantly improved by the use of 2 biomarkers, such as a combination of BAP1 and CDKN2A with fluorescence in situ hybridization or a combination of BAP1 and MTAP immunohistochemistry.
© 2021 American Cancer Society.

Entities:  

Keywords:  biomarker; cytology; diagnostic specificity and sensitivity; effusion; immunohistochemistry; mesothelioma; meta-analysis; pleura; systematic review

Mesh:

Substances:

Year:  2021        PMID: 34478240     DOI: 10.1002/cncy.22509

Source DB:  PubMed          Journal:  Cancer Cytopathol        ISSN: 1934-662X            Impact factor:   5.284


  2 in total

1.  Mesothelioma: A Case in a Diagnostic Timeline and the Efficiency of Robot-Assisted Surgery.

Authors:  Paul Zarogoulidis; Kosmas Tsakiridis; Thomas Zarampoukas; Katerina Zarampouka; Dimitris Hatzibougias; Christos Tolis; Stavros Tryfon; Maria Saroglou; Aris Ioannidis; Dimitris Matthaios; Christoforos Kosmidis
Journal:  Case Rep Oncol       Date:  2022-03-03

2.  A case of slowly progressive malignant pericardial mesothelioma suggesting the involvement of BAP1 loss.

Authors:  Naoto Fukasawa; Yoko Agemi; Aya Shiba; Masaharu Aga; Yusuke Hamakawa; Kazuhito Miyazaki; Yuri Taniguchi; Yuki Misumi; Tsuneo Shimokawa; Kyoko Ono; Hiroyuki Hayashi; Hiroaki Okamoto
Journal:  Respirol Case Rep       Date:  2022-08-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.