Jakub Mercik1, Aleksandra Gajek-Marecka2, Jacek Marcin Zawadzki3, Agnieszka Sławuta4, Jacek Gajek5. 1. Department of Emergency Medicine, Wroclaw Medical University, Wroclaw, Poland. 2. Klodzko County Hospital, Klodzko, Poland. 3. Department of Anesthesia, Critical Care and Emergency Medicine, Collegium Medicum of University in Zielona Góra, Zielona Góra, Poland. 4. Department of Internal and Occupational Diseases, Hypertension and Clinical Oncology, Wroclaw Medical University, Wroclaw, Poland. 5. Department of Emergency Medical Service, Wroclaw Medical University, Wroclaw, Poland.
Abstract
INTRODUCTION: A dual-chamber pacemaker (DDD/R) for a sinus node disease is sometimes referred to as a physiological pacemaker as it maintains atrioventricular synchrony, however several clinical trials have proved its inferiority to a nonphysiological single-chamber ventricular back-up pacing. PATIENT CONCERNS: A subject of the study is a 74-year-old woman with a sick sinus syndrome (SSS) and a previously implanted physiological DDD/R pacemaker. The SSS was diagnosed because of patient's very slow sinus rhythm of about 36 bpm, and due to several episodes of dizziness. After the DDD/R implantation the percentage of atrial pacing approached 100%, with almost none ventricular pacing. DIAGNOSES: Sick sinus syndrome, complete Bachmann's bundle block, atrial fibrillation, atrial flutter. INTERVENTIONS: The patient was previously implanted with a physiological DDD/R pacemaker. Several years after the implantation, the atrial fibrillation was diagnosed and the pulmonary vein isolation was then performed by cryoablation. During the follow-up after pulmonary vein isolation, the improvement of mitral filling parameters was assessed using echocardiography. Shortly thereafter the patient developed the persistent paroxysm of a typical atrial flutter which was successfully terminated using a radiofrequency ablation. No recurrence thereof has been observed ever since (24 months). OUTCOMES: The atrial electrode of the pacing system was implanted within the low interatrial septal region that resulted in a reduced P-wave duration compared to native sinus rhythm P-waves. The said morphology was deformed because of the complete Bachmann bundle block. That approach, despite a nonphysiological direction of an atrial activation, yielded relatively short P-waves (paced P-wave: 179 ms vs intrinsic sinus P-wave: 237 ms). It also contributed to a significantly shorter PR interval (paced PR: 204 ms vs sinus rhythm PR: 254 ms). CONCLUSIONS: The authors took into consideration different aspects of alternative right atrial pacing sites. This report has shown that in some patients with a sinus node disease, low interatrial septal pacing can reduce the P-wave duration but does not prevent from the development of atrial arrhythmias.
INTRODUCTION: A dual-chamber pacemaker (DDD/R) for a sinus node disease is sometimes referred to as a physiological pacemaker as it maintains atrioventricular synchrony, however several clinical trials have proved its inferiority to a nonphysiological single-chamber ventricular back-up pacing. PATIENT CONCERNS: A subject of the study is a 74-year-old woman with a sick sinus syndrome (SSS) and a previously implanted physiological DDD/R pacemaker. The SSS was diagnosed because of patient's very slow sinus rhythm of about 36 bpm, and due to several episodes of dizziness. After the DDD/R implantation the percentage of atrial pacing approached 100%, with almost none ventricular pacing. DIAGNOSES: Sick sinus syndrome, complete Bachmann's bundle block, atrial fibrillation, atrial flutter. INTERVENTIONS: The patient was previously implanted with a physiological DDD/R pacemaker. Several years after the implantation, the atrial fibrillation was diagnosed and the pulmonary vein isolation was then performed by cryoablation. During the follow-up after pulmonary vein isolation, the improvement of mitral filling parameters was assessed using echocardiography. Shortly thereafter the patient developed the persistent paroxysm of a typical atrial flutter which was successfully terminated using a radiofrequency ablation. No recurrence thereof has been observed ever since (24 months). OUTCOMES: The atrial electrode of the pacing system was implanted within the low interatrial septal region that resulted in a reduced P-wave duration compared to native sinus rhythm P-waves. The said morphology was deformed because of the complete Bachmann bundle block. That approach, despite a nonphysiological direction of an atrial activation, yielded relatively short P-waves (paced P-wave: 179 ms vs intrinsic sinus P-wave: 237 ms). It also contributed to a significantly shorter PR interval (paced PR: 204 ms vs sinus rhythm PR: 254 ms). CONCLUSIONS: The authors took into consideration different aspects of alternative right atrial pacing sites. This report has shown that in some patients with a sinus node disease, low interatrial septal pacing can reduce the P-wave duration but does not prevent from the development of atrial arrhythmias.
Authors: Andrew E Epstein; John P DiMarco; Kenneth A Ellenbogen; N A Mark Estes; Roger A Freedman; Leonard S Gettes; A Marc Gillinov; Gabriel Gregoratos; Stephen C Hammill; David L Hayes; Mark A Hlatky; L Kristin Newby; Richard L Page; Mark H Schoenfeld; Michael J Silka; Lynne Warner Stevenson; Michael O Sweeney; Sidney C Smith; Alice K Jacobs; Cynthia D Adams; Jeffrey L Anderson; Christopher E Buller; Mark A Creager; Steven M Ettinger; David P Faxon; Jonathan L Halperin; Loren F Hiratzka; Sharon A Hunt; Harlan M Krumholz; Frederick G Kushner; Bruce W Lytle; Rick A Nishimura; Joseph P Ornato; Richard L Page; Barbara Riegel; Lynn G Tarkington; Clyde W Yancy Journal: J Am Coll Cardiol Date: 2008-05-27 Impact factor: 24.094
Authors: A SippensGroenewegen; H A Peeters; E R Jessurun; A C Linnenbank; E O Robles de Medina; M D Lesh; N M van Hemel Journal: Circulation Date: 1998-02-03 Impact factor: 29.690
Authors: Willem G de Voogt; Rob van Mechelen; Mike Scheffer; Addy J M van Miltenburg van Zijl; Abdou A Elhendy Journal: J Electrocardiol Date: 2005-04 Impact factor: 1.438
Authors: Sanjeev Saksena; Atul Prakash; Paul Ziegler; John D Hummel; Paul Friedman; Vance J Plumb; D George Wyse; Eric Johnson; Stephanie Fitts; Rahul Mehra Journal: J Am Coll Cardiol Date: 2002-09-18 Impact factor: 24.094
Authors: Gervasio A Lamas; Kerry L Lee; Michael O Sweeney; Russell Silverman; Angel Leon; Raymond Yee; Roger A Marinchak; Greg Flaker; Eleanor Schron; E John Orav; Anne S Hellkamp; Stephen Greer; John McAnulty; Kenneth Ellenbogen; Frederick Ehlert; Roger A Freedman; N A Mark Estes; Arnold Greenspon; Lee Goldman Journal: N Engl J Med Date: 2002-06-13 Impact factor: 91.245