Accuracy of non-invasive blood pressure measurement in patients with atrial fibrillation.

Hai Su1, Zihong Guo2.   

Abstract

Although the accuracy of oscillometric blood pressure (BP) measurement is not so satisfied, the BP reading is still associated with cardiovascular events and death in patients with atrial fibrillation (AF). Because the currently used auscultatory or oscillometric methods were developed on sinus rhythm (SR), these BP measurement methods were not reasonable for AF patients. It is suggested that the average of three BP readings in the AF patients is accepted in clinical, even so, high systolic BP (SBP) variability and inaccurate diastolic BP (DBP) value have been reported in AF patients. In sinus rhythm, oscillometric pressure pulses (OPPs) are spindle-like, regardless of the heart rate. However, the shape of OPP is obviously associated with frequency of ventricular rate (VR) in AF patients. When the VR is rapid, the OPP is far from a spindle-like shape. With intro-aortic BP as reference, a study demonstrated that the oscillometric SBP level significantly underestimated the intro-aortic SBP level in the AF patients with increasing VR. In clinical practice, the physician should use the average of three BP readings in the AF patients. When the mean pulse rates (PR) reported by the oscillometric BP devise is less than 90 bpm and the variation of three pulse rate <10 bpm, the oscillometric SBP readings may be clinically accepted in AF patients. It is necessary to develop a new BP measurement method for AF as the current methods in AF are not so accurate as in SR.
© 2021. The Author(s), under exclusive licence to Springer Nature Limited.

Entities:  

Mesh:

Year:  2021        PMID: 34462543     DOI: 10.1038/s41371-021-00596-3

Source DB:  PubMed          Journal:  J Hum Hypertens        ISSN: 0950-9240            Impact factor:   3.012


  5 in total

1.  The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure. 1.

Authors:  J A Posey; L A Geddes; H Williams; A G Moore
Journal:  Cardiovasc Res Cent Bull       Date:  1969 Jul-Sep

2.  [Assessment of auscultatory blood pressure measurements versus intra-arterial pressure in patients with atrial fibrillation].

Authors:  H Ochiai; A Mitake; T Miyata; T Ishigami; K Ashino; S Sumita; N Miyazaki; M Ishii
Journal:  J Cardiol       Date:  1997-06       Impact factor: 3.159

Review 3.  Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association.

Authors:  Paul Muntner; Daichi Shimbo; Robert M Carey; Jeanne B Charleston; Trudy Gaillard; Sanjay Misra; Martin G Myers; Gbenga Ogedegbe; Joseph E Schwartz; Raymond R Townsend; Elaine M Urbina; Anthony J Viera; William B White; Jackson T Wright
Journal:  Hypertension       Date:  2019-05       Impact factor: 10.190

4.  [Reliability of automatic oscillometric monitoring of arterial pressure. Effect of hypotension and arrhythmias].

Authors:  J P Caramella; J M Desmonts
Journal:  Arch Mal Coeur Vaiss       Date:  1986-11

5.  Auscultatory versus oscillometric blood pressure measurement in patients with atrial fibrillation and arterial hypertension.

Authors:  Aistėja Šelmytė-Besusparė; Jūratė Barysienė; Dovilė Petrikonytė; Audrius Aidietis; Germanas Marinskis; Aleksandras Laucevičius
Journal:  BMC Cardiovasc Disord       Date:  2017-03-23       Impact factor: 2.298

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.