Literature DB >> 34424665

Engineering of Electron Affinity and Interfacial Charge Transfer of Graphene for Self-Powered Nonenzymatic Biosensor Applications.

Mohamed Fathi Sanad1,2, Venkata S N Chava1, Ahmed Esmail Shalan3,4, Lissette Garcia Enriquez1, Ting Zheng5, Srikanth Pilla5,6,7,8, Sreeprasad T Sreenivasan1.   

Abstract

Facile electron transport and intimate electronic contact at the catalyst-electrode interface are critical for the ideal performance of electrochemical devices such as glucose biofuel cells and biosensors. Here, through a comprehensive experimental-theoretical exploration, we demonstrate that engineering of interfacial properties, including interfacial electron dynamics, electron affinity, electrode-catalyst-adsorbate electrical synergy, and electrocatalytically active surface area, can lead to highly efficient graphene-based electrochemical devices. We selected two closely related but electronically and surface chemically different functionalized graphene analogues-graphene acid (GA) and reduced graphene oxide (rGO)-as the model graphenic platforms. Our studies reveal that compared to rGO, GA is a superior bifunctional catalyst with high oxygen reduction reaction (an onset potential of 0.8 V) and good glucose oxidation activities. Spectroscopic and electrochemical analysis of GA and rGO indicated that the higher carboxylic acid content on GA increases its overall electron affinity and coupled with improved conductivity and band alignment, which leads to GA's better electrochemical performance. The formulation of a heterostructure between GA and samarium oxide (Sm2O3) nanoparticles led to augmented conductivity (lower charge-transfer resistance) and glucose binding affinity, resulting in a further enhanced glucose oxidation activity. The interdimensional Sm2O3/GA heterostructure, leveraging their enhanced glucose oxidation capacity, exhibited excellent nonenzymatic amperometric glucose sensing performance, with a detection limit of 107 nM and a sensitivity of 20.8 μA/μM. Further, a nonenzymatic, membrane-free glucose biofuel cell (with Sm2O3/GA heterostructure as anode and GA as biocathode) produced a power density of 3.2 μW·cm-2 (in PBS spiked with 3 mM glucose), which can function as self-powered glucose sensors with 70 nM limit of detection. The study establishes the potential of interfacial engineering of GA to engage it as a highly tunable substrate for a broad range of electrochemical applications, especially in future self-powered biosensors.

Entities:  

Keywords:  amperometric sensor; band alignment; graphene acid; heterostructure; interfacial engineering; nonenzymatic glucose biofuel cells; rare earth oxide; self-powered biosensors

Mesh:

Substances:

Year:  2021        PMID: 34424665     DOI: 10.1021/acsami.1c12423

Source DB:  PubMed          Journal:  ACS Appl Mater Interfaces        ISSN: 1944-8244            Impact factor:   9.229


  4 in total

1.  One-pot green synthesis of antimicrobial chitosan derivative nanocomposites to control foodborne pathogens.

Authors:  Mahmoud H Abu Elella; Ahmed Esmail Shalan; Magdy W Sabaa; Riham R Mohamed
Journal:  RSC Adv       Date:  2022-01-05       Impact factor: 3.361

2.  Electrochemical sensor based on screen printed carbon electrode-zinc oxide nano particles/molecularly imprinted-polymer (SPCE-ZnONPs/MIP) for detection of sodium dodecyl sulfate (SDS).

Authors:  Putri Faradilla; Henry Setiyanto; Robeth Viktoria Manurung; Vienna Saraswaty
Journal:  RSC Adv       Date:  2021-12-24       Impact factor: 3.361

3.  Electrocatalytic activity for proton reduction by a covalent non-metal graphene-fullerene hybrid.

Authors:  Demetrios D Chronopoulos; Christina Stangel; Magdalena Scheibe; Klára Čépe; Nikos Tagmatarchis; Michal Otyepka
Journal:  Chem Commun (Camb)       Date:  2022-07-26       Impact factor: 6.065

4.  Electrocatalytic activity of metal encapsulated, doped, and engineered fullerene-based nanostructured materials towards hydrogen evolution reaction.

Authors:  Hitler Louis; Onyinye J Ikenyirimba; Tomsmith O Unimuke; Gideon E Mathias; Terkumbur E Gber; Adedapo S Adeyinka
Journal:  Sci Rep       Date:  2022-09-16       Impact factor: 4.996

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.