Validation of 4D Flow based relative pressure maps in aortic flows.

David Nolte1, Jesús Urbina2, Julio Sotelo3, Leo Sok4, Cristian Montalba5, Israel Valverde6, Axel Osses7, Sergio Uribe2, Cristóbal Bertoglio8.   

Abstract

While the clinical gold standard for pressure difference measurements is invasive catheterization, 4D Flow MRI is a promising tool for enabling a non-invasive quantification, by linking highly spatially resolved velocity measurements with pressure differences via the incompressible Navier-Stokes equations. In this work we provide a validation and comparison with phantom and clinical patient data of pressure difference maps estimators. We compare the classical Pressure Poisson Estimator (PPE) and the new Stokes Estimator (STE) against catheter pressure measurements under a variety of stenosis severities and flow intensities. Specifically, we use several 4D Flow data sets of realistic aortic phantoms with different anatomic and hemodynamic severities and two patients with aortic coarctation. The phantom data sets are enriched by subsampling to lower resolutions, modification of the segmentation and addition of synthetic noise, in order to study the sensitivity of the pressure difference estimators to these factors. Overall, the STE method yields more accurate results than the PPE method compared to catheterization data. The superiority of the STE becomes more evident at increasing Reynolds numbers with a better capacity of capturing pressure gradients in strongly convective flow regimes. The results indicate an improved robustness of the STE method with respect to variation in lumen segmentation. However, with heuristic removal of the wall-voxels, the PPE can reach a comparable accuracy for lower Reynolds' numbers.
Copyright © 2021 The Author(s). Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  4D Flow; Catheter; Clinical and experimental validation; Pressure difference

Mesh:

Year:  2021        PMID: 34419837     DOI: 10.1016/j.media.2021.102195

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  4 in total

1.  Relative pressure estimation from 4D flow MRI using generalized Bernoulli equation in a phantom model of arterial stenosis.

Authors:  Amirkhosro Kazemi; Daniel A Padgett; Sean Callahan; Marcus Stoddard; Amir A Amini
Journal:  MAGMA       Date:  2022-02-17       Impact factor: 2.533

2.  Assessment of 4D flow MRI's quality by verifying its Navier-Stokes compatibility.

Authors:  Jeremías Garay; Hernán Mella; Julio Sotelo; Cristian Cárcamo; Sergio Uribe; Cristóbal Bertoglio; Joaquín Mura
Journal:  Int J Numer Method Biomed Eng       Date:  2022-05-09       Impact factor: 2.648

3.  The impact of 4D-Flow MRI spatial resolution on patient-specific CFD simulations of the thoracic aorta.

Authors:  Zinedine Khatir; Amirul Khan; Malenka Bissell; Molly Cherry
Journal:  Sci Rep       Date:  2022-09-06       Impact factor: 4.996

4.  On the numerical treatment of viscous and convective effects in relative pressure reconstruction methods.

Authors:  Douglas R Q Pacheco
Journal:  Int J Numer Method Biomed Eng       Date:  2021-12-17       Impact factor: 2.648

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.