Brent A Kramer1, John Berdahl, Xiaolin Gu, Mohinder Merchea.
Abstract
PURPOSE: To determine the 12-month incidence of reoperation to realign 2 commercially available types of implanted monofocal toric acrylic intraocular lenses (IOLs).Entities:
Mesh:
Year: 2022 PMID: 34415862 PMCID: PMC8865207 DOI: 10.1097/j.jcrs.0000000000000748
Source DB: PubMed Journal: J Cataract Refract Surg ISSN: 0886-3350 Impact factor: 3.528
ICD-10 Diagnoses Included in the Analysis.
| Code | Description |
| H25.011 | Cortical age-related cataract, right eye |
| H25.012 | Cortical age-related cataract, left eye |
| H25.013 | Cortical age-related cataract, bilateral |
| H25.11 | Age-related nuclear cataract, right eye |
| H25.12 | Age-related nuclear cataract, left eye |
| H25.13 | Age-related nuclear cataract, bilateral |
| H25.89 | Other age-related cataract |
| H25.21 | Age-related cataract, morgagnian type (hypermature), right eye |
| H25.22 | Age-related cataract, morgagnian type (hypermature), left eye |
| H25.23 | Age-related cataract, morgagnian type (hypermature), bilateral |
| H25.811 | Combined forms of age-related cataract, right eye |
| H25.812 | Combined forms of age-related cataract, left eye |
| H25.813 | Combined forms of age-related cataract, bilateral |
ICD-10 = International Classification of Diseases, 10th Revision
IOL Models Included in the Analysis.
| Type | Brand | |
| AcrySof | TECNIS | |
| Monofocal | SN60WF, SA60WF, SN60AT, and SA60AT | ZCB00 |
| Monofocal toric | SN6AT3, SN6AT4, SN6AT5, SN6AT6, SN6AT7, SN6AT8, SN6AT9, SA6AT3, SA6AT4, SA6AT5, SA6AT6, SA6AT7, SA6AT8, and SA6AT9 | ZCT150, ZCT225, ZCT300, ZCT400, ZCT425, ZCT525, and ZCT600 |
| Multifocal | SN6AD1, SV25T0, and SN6AD3 | ZKB00, ZLB00, and ZMB00 |
| Multifocal toric | SND1T3, SND1T4, SND1T5, SND1T6, SV25T3, SV25T4, SV25T5, and SV25T6 | NA |
| Diffractive EDoF/EDF | NA | ZXR00 |
| Diffractive EDoF/EDF toric | NA | ZXT150, ZXT225, ZXT300, and ZXT375 |
EDoF/EDF = extended depth of focus
Demographic Characteristics.
| Characteristic | AcrySof (N = 4469) | TECNIS (N = 2013) | |
| Age (y), mean ± SD | 69.9 ± 7.9 | 69.4 ± 8.3 | .05 |
| Female, n (%) | 2691 (60.2) | 1218 (60.5) | .85 |
| Race, n (%) | |||
| White | 3953 (88.5) | 1767 (87.8) | .33 |
| Black | 78 (1.7) | 46 (2.3) | |
| Other or not reported | 438 (9.8) | 200 (9.9) | |
| U.S. geographical region, n (%) | |||
| Midwest | 1442 (32.3) | 522 (25.9) | <.0001 |
| North | 456 (10.2) | 269 (13.4) | |
| South | 2030 (45.4) | 830 (41.2) | |
| West | 541 (12.1) | 392 (19.5) |
Figure 1.Incidence of reoperation for IOL realignment ( CPT code 66825) within 365 days of surgery by IOL brand. AcrySof toric IOLs were found to require less additional repositioning than TECNIS toric IOLS (*P < .0001; chi-square test). CPT = Current Procedural Terminology
Figure 2.Risk factors for IOL repositioning within 365 days of primary surgery.