| Literature DB >> 34411845 |
Baoguo Xu1, Jianan Chen2, Essodézam Sylvain Tiliwa2, Weiqiang Yan3, S M Roknul Azam4, Jun Yuan5, Benxi Wei2, Cunshan Zhou2, Haile Ma4.
Abstract
The effects of osmotic pretreatment assisted by ultrasound in different frequency modes before vacuum freeze-drying (VFD) on moisture migration and quality characteristics of strawberry slices were investigated. The frequency modes are single-frequency modes under 20, 40 kHz (SM-20, SM-40), and dual-frequency under 20/40 kHz including sequential mode (SeDM) and simultaneous mode (SiDM). The quality characteristics of dried strawberry products including rehydration, hardness, color, flavor, total anthocyanins, total phenols, vitamin C content, and active antioxidant components (DPPH and -OH) were determined. Results showed that drying time of the strawberry slices irradiated by ultrasound was reduced by 15.25%-50.00%, compared to the control samples. Besides, dual-frequency ultrasound shortened the drying time more than single-frequency ultrasound. The drying time of SeDM was the shortest. In addition to vitamin C content, the quality characteristics including rehydration, hardness, color, flavor, total anthocyanins, total phenols, and antioxidant activity of dried strawberry products pretreated by SeDM were significantly (p < 0.05) better than those of control and other pretreated samples. It can be concluded that the SeDM was an effective pretreatment method to produce high-quality vacuum freeze-dried strawberry products.Entities:
Keywords: Strawberry; Ultrasonic; Vacuum freeze-drying; Water migration
Mesh:
Substances:
Year: 2021 PMID: 34411845 PMCID: PMC8379497 DOI: 10.1016/j.ultsonch.2021.105714
Source DB: PubMed Journal: Ultrason Sonochem ISSN: 1350-4177 Impact factor: 7.491
Fig. 1The schematic diagram of experiments.
Fig. 2Effect of different pretreatment methods on the drying characteristics of strawberry during VFD. A: Effect of different pretreatments on the water loss (WL) and solid gain (SG) of strawberry; B: Effect of pretreatments on the change of moisture ratio with time during the VFD process of strawberry; C: Effect of pretreatments on the drying rate of strawberry during the VFD; D: Effect of pretreatments on the total VFD time of strawberry.
Fig. 3Microstructure image of dried strawberry with different pretreatments. Magnification: 100×. Control: no-ultrasound; SM-20: single-frequency mode of 20 kHz; SM-40: single-frequency mode of 40 kHz; SeDM: sequential dual-frequency mode of 20/40 kHz; SiDM: simultaneous dual-frequency mode of 20 and 40 kHz.
Fig. 4Typical distribution of T2 relaxation time and MRI images of different pretreatment methods VFD strawberry slices before and after drying. A: Distribution of T2 relaxation times of pre-dry strawberry slices; B: Distribution of T2 relaxation times of dried strawberry slices; C: MRI images of different pretreatment methods VFD strawberry slices before and after drying.
The relaxation time (T21, T22 and T23) and relative peak area (A21, A22 and A23) of strawberry samples pretreated before and after drying.
| Mode | T2 (ms) | Area of T2 (%) | |||||
|---|---|---|---|---|---|---|---|
| T21 | T22 | T23 | A21 | A22 | A23 | ||
| Pretreatment | Control | 0.43 ± 0.05c | 265.61 ± 5.01a | 1072.27 ± 3.35b | 2.19 ± 0.10a | 39.26 ± 0.20d | 58.55 ± 0.51a |
| SM-20 | 1.75 ± 0.09b | 256.23 ± 4.20b | 925.26 ± 5.02e | 0.91 ± 0.07b | 48.78 ± 0.21b | 50.31 ± 0.32c | |
| SM-40 | 10.11 ± 0.10a | 231.01 ± 4.51c | 936.60 ± 3.71d | 0.72 ± 0.08c | 58.90 ± 0.15a | 40.38 ± 0.15e | |
| SeDM | — | 200.92 ± 4.24d | 1232.85 ± 6.02a | — | 57.79 ± 1.65a | 42.21 ± 0.25d | |
| SiDM | — | 206.02 ± 3.62d | 1065.07 ± 7.65c | — | 46.71 ± 0.22c | 53.29 ± 0.51b | |
| Vacuum freeze drying | Control | 0.43 ± 0.05a | 7.06 ± 0.13a | 75.65 ± 0.15a | 29.33 ± 0.15c | 39.62 ± 0.14b | 31.05 ± 0.50a |
| SM-20 | 0.22 ± 0.02bc | 6.14 ± 0.15c | 68.27 ± 0.21c | 32.24 ± 1.07b | 40.08 ± 0.45b | 27.68 ± 0.33c | |
| SM-40 | 0.38 ± 0.08a | 6.77 ± 0.20b | 70.83 ± 0.12b | 30.70 ± 0.25bc | 39.83 ± 0.18b | 29.47 ± 0.18b | |
| SeDM | 0.14 ± 0.04c | 4.64 ± 0.15d | 49.77 ± 0.15e | 42.33 ± 1.12a | 38.55 ± 0.31c | 19.12 ± 0.14d | |
| SiDM | 0.25 ± 0.05b | 4.82 ± 0.21d | 65.79 ± 0.12d | 24.33 ± 0.70d | 48.17 ± 0.20a | 27.50 ± 0.29c | |
Note: Values are means ± SD, n ≥ 3. Different letters in the same column mean significant difference at p < 0.05. T23 refers to the the free water’s transverse relaxation time; T21 and T22 refer to the transverse relaxation time of the bound water and the immobilized water, respectively. A21 represents the corresponding water fraction to T21, A22 represents the corresponding water fraction to T22, and A23 represents the corresponding water fraction to T23. Control: no-ultrasound; SM-20: single-frequency mode of 20 kHz; SM-40: single-frequency mode of 40 kHz; SeDM: sequential dual-frequency mode of 20/40 kHz; SiDM: simultaneous dual-frequency mode of 20 and 40 kHz.
Fig. 5Effect of pretreatments on the quality of strawberry subjected to VFD. A: Effect of pretreatments on rehydration ratio (bar graph) and hardness (line graph) of strawberry after VFD; B: Effect of pretreatments on the color of strawberry after VFD; C: Radar chart of the effect of pretreatments on flavor substances of strawberry after VFD; D: Effect of pretreatments on main components of flavor substances of strawberry after VFD.
Total anthocyanin content, total phenolic content, vitamin C and antioxidant capacity of the dried strawberry samples.
| Control | SM-20 | SM-40 | SeDM | SiDM | |
|---|---|---|---|---|---|
| TAC (mg C3G/g) | 0.88 ± 0.02d | 0.95 ± 0.03c | 1.02 ± 0.01b | 1.10 ± 0.02a | 1.04 ± 0.02ab |
| TPC (mg GAE/g) | 24.32 ± 0.12e | 25.84 ± 0.09d | 27.28 ± 0.14c | 31.83 ± 0.07a | 28.97 ± 0.11b |
| VC (mg AA/g) | 2.38 ± 0.06a | 2.22 ± 0.08b | 2.12 ± 0.05bc | 2.08 ± 0.02c | 1.77 ± 0.04d |
| DPPH (%) | 53.58 ± 0.66e | 55.45 ± 0.29d | 57.43 ± 0.52c | 63.11 ± 0.74a | 58.36 ± 0.87b |
| –OH (%) | 93.17 ± 0.14d | 99.67 ± 0.32b | 98.94 ± 0.37c | 102.32 ± 0.76a | 102.20 ± 0.21a |
Note: Values are means ± SD, n ≥ 3. Different letters in the same column mean significant difference at p < 0.05. Control: no-ultrasound; SM-20: single-frequency mode of 20 kHz; SM-40: single-frequency mode of 40 kHz; SeDM: sequential dual-frequency mode of 20/40 kHz; SiDM: simultaneous dual-frequency mode of 20 and 40 kHz.