Literature DB >> 34409221

Investigation of the Lower Punctum Parameters: A Spectral Domain Anterior Segment Optical Coherence Tomography Study.

Aliakbar Sabermoghaddam1, Shahin Golestani1, Kiana Hassanpour2, Elham Bakhtiari3.   

Abstract

PURPOSE: To evaluate the dimensions of lower punctum in a sample of Iranian normal population using spectral domain anterior segment optical coherence tomography (OCT).
METHODS: In this cross-sectional study, 102 eyes of 102 healthy volunteers were enrolled. All participants underwent a detailed history and complete ophthalmic examination. Lower punctum metrics were measured using OCT (Spectralis, Heidelberg) with the anterior segment module. External punctal diameter was defined as the largest diameter at the surface of the punctum. Internal punctal diameter was measured at two different depths of 100 μm and 500 μm from the external surface. Measurements were repeated for 30% of data by another grader. The agreement was measured using intraclass correlation coefficient (ICC).
RESULTS: The mean age of the participants was 61.5 ± 7.9 years. The mean external punctal diameter was 425.6 ± 124.3 μm. The mean internal punctal diameter at 100 μm and 500 μm was 183 ± 97.5 μm and 77.7 ± 51.4 μm, respectively. The agreement between the graders was high in assessing all punctal characteristics (ICC >0.9 for all measurements).
CONCLUSION: The spectral domain OCT can be used for measuring lower punctum diameter with acceptable reproducibility. Copyright:
© 2021 Journal of Current Ophthalmology.

Entities:  

Keywords:  Epiphora; Optical coherence tomography; Punctum

Year:  2021        PMID: 34409221      PMCID: PMC8365571          DOI: 10.4103/JOCO.JOCO_131_20

Source DB:  PubMed          Journal:  J Curr Ophthalmol        ISSN: 2452-2325


INTRODUCTION

The punctum is the only visible part of the tear drainage system. The upper and lower eyelid punctum are located at the apex of the lacrimal papillae on the upper and lower eyelid margins.1 Understanding the normal anatomy of the punctum is essential to treat a variety of diseases such as stenosis or improper dilatation of the punctum, which could lead to disruption of the tear flow.2 Furthermore, understanding the normal punctum anatomy could be helpful for more accurate design of punctal plugs. Most of our knowledge about the normal anatomy of lacrimal drainage system has come from cadaver studies. However, numerous methods such as ultrasonography have been used for accurate measuring of the anatomical dimensions in in vivo condition.34 Recently, optical coherence tomography (OCT) has been introduced to assess the punctum and proximal part of canaliculus. Wawrzynski et al.5 showed that OCT could provide high-resolution images of the punctum and vertical canaliculus. However, normal values of these OCT measures have yet to be determined in different populations. The aim of this study was to evaluate the lower punctum features in Iranian normal population using OCT.

METHODS

In this cross-sectional study, healthy volunteers aged between 20 and 70 years were recruited. Most of them were companies of the outpatients referred to Khatam-Al-Anbia Eye Hospital, Mashhad, Iran. The study protocol was approved by the Ethics Committee of Mashhad University of Medical Sciences (Ethics code of IR.MUMS.fm.REC.1396.764). Written informed consent was obtained from all participants. The study protocol adhered to the Declaration of Helsinki. All participants underwent a detailed history and complete ophthalmic examination. Lid margins were thoroughly examined. Slit-lamp biomicroscopy and evaluation of the ocular surface were performed as well. The subjects with epiphora, long-term use of ocular drops except for artificial tears, previous history of chemotherapy, lower eyelid anomalies, lesions or history of the lid and lacrimal drainage disease, or surgery were excluded. Patients with tear meniscus height >2 mm or tear break-up time test <5 s were also excluded. In each patient, only one eye was enrolled in the study. All OCT images were obtained by one experienced operator on a separate day without any further manipulation for ophthalmic examination. Lower punctum metrics measurements were performed using OCT (Spectralis, Heidelberg Engineering, Heidelberg, Germany) set on the anterior segment module [Figure 1]. This system acquires 40,000 A-scans/second with a 7-μm axial resolution in tissue. All images were acquired using the scleral setting, a mode in which enhanced depth imaging can be performed. While the eyes were open and the lower eyelid margin was everted using a cotton swap without any pressure, the lower punctum was positioned to a plane perpendicular to the light source. The brightness was set to be 25%, and the angle of each cross-sectional scan was 15°. Images were obtained at a working distance of about 12 mm with 8 mm coverage of the lower eyelids. Automated real-time setting with an average between 2 and 20 frames was chosen. Three OCT images were obtained for each subject, and the highest quality scan was chosen subjectively.
Figure 1

Representative image of anterior segment optical coherence tomography of the inferior punctum

Representative image of anterior segment optical coherence tomography of the inferior punctum Measurements of lacrimal punctal anatomy, as visualized on OCT, were taken using Heidelberg Eye Explorer software (version 1.6.8) (Heidelberg Engineering, Heidelberg, Germany). The best and clearest one was chosen for measuring the lower punctum diameters. A skilled grader (A.S.) measured the dimensions. External punctal diameter was defined as the largest diameter at the surface of the punctum. Internal punctal diameter was measured at two different canalicular depths of 100 and 500 μm from the external punctum [Figure 1]. To evaluate the reproducibility, 30% of measurements were repeated by another experienced researcher (S.G.). Statistical analysis was performed using SPSS windows program version 16 (SPSS Institute, Inc., Chicago, IL, USA). All experimental values are presented as mean ± standard deviation and median and interquartile range (IQR). Normal distribution was evaluated using Kolmogorov–Smirnov test. P < 0.05 was considered statistically significant. The comparison between men and women was done by independent t-test. Pearson's correlation coefficient was used to evaluate the linear relationship between variables. The agreement between observers was measured using intraclass correlation coefficient (ICC) with single measures, absolute agreement method.

RESULTS

One hundred and two eyes of 102 healthy volunteers were enrolled in the present study. The mean age of the participants was 61.5 ± 7.9 years (29–69 years), and 53 (52%) of them were male. The mean external punctal diameter was 425.6 ± 124.3 μm (median, IQR: 403, 336.2–503.2 μm). Mean internal punctal diameter at 100 μm and 500 μm was 191.6 ± 101.7 μm (median, IQR: 155, 107.2–262) and 79.6 ± 61.4 μm (median, IQR: 61, 44–98.5), respectively. All values showed normal distributions in the study participants. There was a significant correlation between external punctal diameter and internal punctal diameter at 100 μm (r = 0.821; P < 0.0001) and 500 μm (r = 0.770; P = 0.006). There was no significant difference between men and women in all punctal measurements [Table 1]. There was no significant correlation between age and punctal measurements (P > 0.05).
Table 1

Punctal characteristics in the study population

VariablesTotal (n=102)Male (n=53)Female (n=49)P*
External punctal diameter
 Mean±SD425.6±124.3434.5±134.5416±112.90.455
 Median403408399
 IQR336.2-503.2340-563319-492
Internal punctal diameter at 100 mm
 Mean±SD183±97.5191.6±101.7173.8±92.80.360
 Median155162140
 IQR107.2-262119-27599-234
Internal punctal diameter at 500 mm
 Mean±SD77.7±51.479.6±61.475.7±38.40.709
 Median615269
 IQR44-98.543-10444-96

*Based on student’s t-test. SD: Standard deviation, IQR: Interquartile range

Punctal characteristics in the study population *Based on student’s t-test. SD: Standard deviation, IQR: Interquartile range There was a good agreement between graders in measuring punctal diameters. ICC was 0.928 for external punctal diameter, 0.950 for internal punctal diameter at 100 μm, and 0.901 for internal punctal diameter at 500 μm.

DISCUSSION

In the present study, we used OCT to measure lower punctum dimensions in Iranian healthy subjects. The punctum could be recognized and measured on the OCT images in all subjects. There was a good agreement between observers in assessing the punctal dimensions. Understanding the anatomy of the punctum and the vertical portion of the lacrimal canal plays an important role in the success of lacrimal system surgeries and can also help determine the etiology of epiphora, especially in patients with punctal stenosis and obstruction.6 Furthermore, the design, fitting, and insertion of the punctal plug are dependent on knowing the exact anatomy of this part.78 The use of lacrimal system imaging techniques can be helpful in the diagnosis of lacrimal canal disease. Because of the surface and prominent status of the lacrimal canal, imaging techniques commonly used for the evaluation of the lacrimal drainage system such as dacryocystography,9 ultrasound biomicroscopy,34 and magnetic resonance imaging may not accurately represent the size of the punctum.10 Anterior segment OCT is a noncontact imaging modality that uses infrared light at a wavelength of 840 nm to image the anterior segment structures of the eye.11 Wawrzynski et al.5 were the first to demonstrate its applicability for evaluation of the lower punctum diameter and vertical canaliculus. They evaluated 36 eyes and provide the OCT measurements of the width of the punctum, and the width, depth, and cross-sectional area of the visualized canaliculi using Topcon 3D OCT. Afterward, some other studies applied OCT in assessing the punctal features and provided the values for the variables, including inner punctal diameter at different depth, punctal depth, and intrapunctal tear meniscus depth.121314 In our study, the mean outer punctal diameter was 425.6 μm which is in the range of the reported values (215–645 μm) in previous studies. The inner punctal diameter in our study was 183 μm at 100 μm and 77.7 μm at 500 μm from the surface. The reported inner punctal diameter values (50–234 μm) showed even more variability in different investigations. However, this is mainly due to different definition of this dimension. Similar to Timlin et al.,12 we measured the inner punctal diameter at a fixed distance from surface which could facilitate to provide better comparison between studies. OCT-based evaluation of lacrimal drainage system, however, has some limitations. First, the assessment of the upper punctum is challenging. The upper punctum is slightly rotated posteriorly, and it is difficult to rotate the opening.12 This could be remedied by designing newer devices that would direct the infrared at the right angle to the upper punctum. Second, the exact effect of everting the lower eyelid margin on punctum size is not clear. Third, the dimensions are currently measured manually, since no automatic software is available for punctal diameters. On the other hand, the ability to capture images quickly without the need for eye contact and the ability to three-dimensional reconstruct and visualize the surface of a puncture are undeniable benefits of OCT. In conclusion, OCT is a useful technique for imaging the inferior punctum. Values measured by OCT have acceptable reproducibility and can be evaluated for this purpose.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  13 in total

1.  Proximal canalicular imaging utilizing ultrasound biomicroscopy A: Normal canaliculi.

Authors:  Jeffrey J. Hurwitz; Charles J. Pavlin; Abdul Hassan
Journal:  Orbit       Date:  1998-03

2.  20-MHz ultrasound and its value in imaging of lacrimal plugs.

Authors:  Frank H W Tost; Jaques Darman; Stefan Clemens
Journal:  Ophthalmologica       Date:  2004 Jan-Feb       Impact factor: 3.250

3.  Anatomical utility of ultrasound biomicroscopy in the lacrimal drainage system.

Authors:  Yasser H Al-Faky
Journal:  Br J Ophthalmol       Date:  2011-01-21       Impact factor: 4.638

4.  Imaging of proximal lacrimal system with time domain anterior segment optical coherence tomography in Asian Indian population.

Authors:  Swati Singh; Arnav Ghosh; Suryasnata Rath
Journal:  Orbit       Date:  2017-06-22

5.  Optical coherence tomography imaging of the proximal lacrimal system.

Authors:  James R Wawrzynski; Julie Smith; Anant Sharma; George M Saleh
Journal:  Orbit       Date:  2014-09-12

6.  Technical note: computed tomographic dacryocystography.

Authors:  D W Waite; H B Whittet; G A Shun-Shin
Journal:  Br J Radiol       Date:  1993-08       Impact factor: 3.039

7.  Stenotic puncta: microsurgical punctoplasty.

Authors:  W N Offutt; D E Cowen
Journal:  Ophthalmic Plast Reconstr Surg       Date:  1993       Impact factor: 1.746

Review 8.  Clinical and research applications of anterior segment optical coherence tomography - a review.

Authors:  Jose Luiz Branco Ramos; Yan Li; David Huang
Journal:  Clin Exp Ophthalmol       Date:  2008-11-05       Impact factor: 4.207

9.  Acquired external punctal stenosis: etiology and associated findings.

Authors:  Mohsen Bahmani Kashkouli; Bijan Beigi; Rachna Murthy; Nick Astbury
Journal:  Am J Ophthalmol       Date:  2003-12       Impact factor: 5.258

10.  The Application of Infrared Imaging and Optical Coherence Tomography of the Lacrimal Punctum in Patients Undergoing Punctoplasty for Epiphora.

Authors:  Hannah M Timlin; Pearse A Keane; Geoffrey E Rose; Daniel G Ezra
Journal:  Ophthalmology       Date:  2017-03-17       Impact factor: 12.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.