The validity of determinations of pulmonary wedge pressure during mechanical ventilation.

R Davison, M Parker, R A Harrison.   

Abstract

Changes in the mean pulmonary wedge pressure were measured during temporary disconnection from a ventilator in 29 patients to assess the effects of therapy with controlled-volume ventilation on determinations of pulmonary wedge pressure. In 16 observations performed during therapy with intermittent positive-pressure ventilation, the mean value for the pulmonary wedge pressure was the same (10.3 mm Hg) with the patients connected to or disconnected from the ventilator. Thirteen of the patients were also maintained on therapy with positive end-expiratory pressure (PEEP); the mean (+/- SD) of 17 measurements of pulmonary wedge pressure did not show a significant variation on cessation of mechanical ventilation (12.5 +/- 6.7 mm Hg vs 11.7 +/- 6.9 mm Hg; P greater than 0.05). We conclude that pulmonary wedge pressure can be measured accurately at the end of exhalation during the administration of positive-pressure ventilation with 10 cm H2O of PEEP. The suggested practice of discontinuing mechanical ventilation in order to obtain a more exact measurement is not warranted.

Entities:  

Mesh:

Year:  1978        PMID: 344008     DOI: 10.1378/chest.73.3.352

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  1 in total

1.  Common artifacts of pulmonary artery and pulmonary artery wedge pressures: recognition and interpretation.

Authors:  E A Schmitt; C O Brantigan
Journal:  J Clin Monit       Date:  1986-01
  1 in total