Literature DB >> 3437815

19F magnetic resonance imaging of the reticuloendothelial system.

A V Ratner1, R Hurd, H H Muller, B Bradley-Simpson, W Pitts, D Shibata, C Sotak, S W Young.   

Abstract

In this study sequential 1H and 19F magnetic resonance imaging methods were used to map the distribution of fluorinated compounds in vivo. An intravenously administered emulsion of perfluorooctylbromide (PFOB), an agent known to localize in the reticuloendothelial system, was detected in the liver and spleen of all studied hamsters and mice using 19F MRI. Lungs and salivary glands were also affected in some animals. Using a G. E. NMR CSI 2-T spectroscopy/imaging system, projection 19F images were obtained in 4 to 8 min. Subsequent mouse studies using a thick-slice driven equilibrium pulse sequence produced 19F images with an improved signal-to-noise ratio in a shorter acquisition time. With PFOB, 19F MRI has the capability of detecting macrophages in the reticulo-endothelial system and in other sites where macrophages congregate. This is the first report where the reticuloendothelial system was specifically imaged in live animals and where driven equilibrium imaging techniques have been applied to 19F MRI.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3437815     DOI: 10.1002/mrm.1910050605

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Dissociation of 19F and fluorescence signal upon cellular uptake of dual-contrast perfluorocarbon nanoemulsions.

Authors:  Pascal Bouvain; Vera Flocke; Wolfgang Krämer; Rolf Schubert; Jürgen Schrader; Ulrich Flögel; Sebastian Temme
Journal:  MAGMA       Date:  2018-11-29       Impact factor: 2.310

2.  Fluorous-Soluble Metal Chelate for Sensitive Fluorine-19 Magnetic Resonance Imaging Nanoemulsion Probes.

Authors:  Amin Haghighat Jahromi; Chao Wang; Stephen R Adams; Wenlian Zhu; Kazim Narsinh; Hongyan Xu; Danielle L Gray; Roger Y Tsien; Eric T Ahrens
Journal:  ACS Nano       Date:  2018-12-07       Impact factor: 15.881

3.  Assaying macrophage activity in a murine model of inflammatory bowel disease using fluorine-19 MRI.

Authors:  Deepak K Kadayakkara; Sarangarajan Ranganathan; Won-Bin Young; Eric T Ahrens
Journal:  Lab Invest       Date:  2012-02-13       Impact factor: 5.662

Review 4.  Fluorine-containing nanoemulsions for MRI cell tracking.

Authors:  Jelena M Janjic; Eric T Ahrens
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2009 Sep-Oct

Review 5.  In vivo MRI cell tracking using perfluorocarbon probes and fluorine-19 detection.

Authors:  Eric T Ahrens; Jia Zhong
Journal:  NMR Biomed       Date:  2013-04-22       Impact factor: 4.044

6.  A systematic optimization of 19F MR image acquisition to detect macrophage invasion into an ECM hydrogel implanted in the stroke-damaged brain.

Authors:  Harmanvir Ghuman; T Kevin Hitchens; Michel Modo
Journal:  Neuroimage       Date:  2019-08-10       Impact factor: 6.556

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.