A performance comparison of the most commonly used minimally invasive monitors of cardiac output.

Jonathan J Gamble1, William P McKay2, Barbara Ambros3, Grant G Miller4, Andrea Vasquez Camargo5, Jonathan Norton4, Jayden Cowan2, Jean du Rand4, Erick D McNair6, Kris Milbrandt4, Martin Gérard2, Maria Valentina Carrozzo3.   

Abstract

BACKGROUND: Shock is common in critically ill and injured patients. Survival during shock is highly dependent on rapid restoration of tissue oxygenation with therapeutic goals based on cardiac output (CO) optimization. Despite the clinical availability of numerous minimally invasive monitors of CO, limited supporting performance data are available.
METHODS: Following approval of the University of Saskatchewan Animal Research Ethics Board, we assessed the performance and trending ability of PiCCOplus™, FloTrac™, and CardioQ-ODM™ across a range of CO states in pigs. In addition, we assessed the ability of invasive mean arterial blood pressure (iMAP) to follow changes in CO using a periaortic transit-time flow probe as the reference method. Statistical analysis was performed with function-fail, bias and precision, percent error, and linear regression at all flow, low-flow (> 1 standard deviation [SD] below the mean), and high-flow (> 1 SD above the mean) CO conditions.
RESULTS: We made a total of 116,957 paired CO measurements. The non-invasive CO monitors often failed to provide a CO value (CardioQ-ODM: 40.6% failed measurements; 99% confidence interval [CI], 38.5 to 42.6; FloTrac: 9.6% failed measurements; 99% CI, 8.7 to 10.5; PiCCOplus: 4.7% failed measurements; 99% CI, 4.5 to 4.9; all comparisons, P < 0.001). The invasive mean arterial pressure provided zero failures, failing less often than any of the tested CO monitors (all comparisons, P < 0.001). The PiCCOplus was most interchangeable with the flow probe at all flow states: PiCCOplus (20% error; 99% CI, 19 to 22), CardioQ-ODM (25% error; 99% CI, 23 to 27), FloTrac (34% error; 99% CI, 32 to 38) (all comparisons, P < 0.001). At low-flow states, CardioQ-ODM (43% error; 99% CI, 32 to 63) and Flotrac (45% error; 99% CI, 33 to 70) had similar interchangeability (P = 0.07), both superior to PiCCOplus (48% error; 99% CI, 42 to 60) (P < 0.001). Regarding CO trending, the CardioQ-ODM (correlation coefficient, 0.82; 99% CI, 0.81 to 0.83) was statistically superior to other monitors including iMAP, but at low flows iMAP (correlation coefficient, 0.58; 99% CI, 0.58 to 0.60) was superior to all minimally invasive CO monitors (all comparisons P < 0.001).
CONCLUSIONS: None of the minimally invasive monitors of CO performed well at all tested flows. Invasive mean arterial blood pressure most closely tracked CO change at critical flow states.
© 2021. Canadian Anesthesiologists' Society.

Entities:  

Keywords:  Anesthesia and analgesia; Arterial pressure; Cardiac output; Hemodynamics; Monitoring; physiologic

Mesh:

Year:  2021        PMID: 34374024     DOI: 10.1007/s12630-021-02085-0

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   6.713


  7 in total

1.  Statistics corner: A guide to appropriate use of correlation coefficient in medical research.

Authors:  M M Mukaka
Journal:  Malawi Med J       Date:  2012-09       Impact factor: 0.875

Review 2.  Impact of hemorrhage on trauma outcome: an overview of epidemiology, clinical presentations, and therapeutic considerations.

Authors:  David S Kauvar; Rolf Lefering; Charles E Wade
Journal:  J Trauma       Date:  2006-06

3.  Sternal acceleration ballistocardiography and arterial pressure wave analysis to determine stroke volume.

Authors:  W P McKay; P H Gregson; B W McKay; J Militzer
Journal:  Clin Invest Med       Date:  1999-02       Impact factor: 0.825

Review 4.  Improving bioscience research reporting: the ARRIVE guidelines for reporting animal research.

Authors:  Carol Kilkenny; William J Browne; Innes C Cuthill; Michael Emerson; Douglas G Altman
Journal:  PLoS Biol       Date:  2010-06-29       Impact factor: 8.029

5.  Evaluation of a novel closed-loop fluid-administration system based on dynamic predictors of fluid responsiveness: an in silico simulation study.

Authors:  Joseph Rinehart; Brenton Alexander; Yannick Le Manach; Christoph Hofer; Benoit Tavernier; Zeev N Kain; Maxime Cannesson
Journal:  Crit Care       Date:  2011-11-23       Impact factor: 9.097

6.  Pulmonary Artery Catheter (PAC) Accuracy and Efficacy Compared with Flow Probe and Transcutaneous Doppler (USCOM): An Ovine Cardiac Output Validation.

Authors:  Robert A Phillips; Sally G Hood; Beverley M Jacobson; Malcolm J West; Li Wan; Clive N May
Journal:  Crit Care Res Pract       Date:  2012-05-09

Review 7.  Single-dose intravenous diclofenac for acute postoperative pain in adults.

Authors:  Ewan D McNicol; McKenzie C Ferguson; Roman Schumann
Journal:  Cochrane Database Syst Rev       Date:  2018-08-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.